DAIKIN FDYA140A-C2V 14.0kW Premium Inverter Ducted System 1 Phase
FDYA140A-C2V
Price: (Inc GST)
PRODUCT INFORMATION
- Ducted Premium Inverter one phase
- SKU: FDYA140A-C2V / BRC1E63
- 14.0 kW Cooling/16.5 kW Heating
- DAIKIN FDYA140A-C2V (Previously known: FDYA140A-CV ) 14.0 kW Reverse Cycle Premium Inverter Ducted Air Conditioner System 1 Phase
- Indoor: FDYA140AV1
- Outdoor: RZAS140C2V1 (Previously known: RZAS140CV1)
- Available Controllers
- R32 | SUPERIOR ENERGY PERFORMANCE
KEY FEATURES
It’s the unique features of Daikin products that makes us the world leader.
Industry Leading Energy Performance: Achieved with a redesigned cross-pass heat exchanger, DC fan motor and improved refrigerant control technology.
Night Quiet Mode: Reduces the outdoor noise levels during sleeping hours and automatically resumes normal operations in the morning.
Increased Operation Limits: The refrigerant cooled PCB technology incorporated in the outdoor unit enables continuous operations up to 50°CDB ambient.
Heating Focus Option: Heating Focus models are available from 18.0-24.0kW with improved heating performance, ideal for cold climates such as Canberra, Hobart & Melbourne.
R22 Retrofit Capability: Provides a cost effective and convenient upgrade from an existing R22 ducted system whilst retaining the field piping (not available for Heating Focus models).
Australian Made: Indoor units are specifically designed and manufactured to Australian standards to withstand the harsher summer climate.
Specifications
| INDOOR UNIT | FDYA140AV1 | |
| OUTDOOR UNIT | RZAS140C2V1 | |
| Rated Capacity | Cool (kW) | 14.0 |
| Heat (kW) | 16.5 | |
| Capacity Range | Cool (kW) | 5.0-16.0 |
| Heat (kW) | 5.1-18.0 | |
| Power Input (Rated) | Cool (kW) | 3.93 |
| Heat (kW) | 4,28 | |
| E.E.R/C.O.P | C/H | 3.56/3.86 |
Specifications
| INDOOR UNIT | FDYA140AV1 | |
| OUTDOOR UNIT | RZAS140C2V1 | |
| Rated Capacity | Cool (kW) | 14.0 |
| Heat (kW) | 16.5 | |
| Capacity Range | Cool (kW) | 5.0-16.0 |
| Heat (kW) | 5.1-18.0 | |
| Power Input (Rated) | Cool (kW) | 3.93 |
| Heat (kW) | 4,28 | |
| E.E.R/C.O.P | C/H | 3.56/3.86 |
| TCSPF (Residential) | Hot/Average/Cold | 5.00/4.55/4.69 |
| HSPF (Residential) | Hot/Average/Cold | 4.11/3.67/3.16 |
| Airflow Rate (Nominal/Max) | l/s | 900/1000 |
| Indoor Sound Level (H) @ 1.5m | dBA (C/H) | 45.9/47.4 |
| Piping Length | m | 75 |
| Indoor Fan Speeds | H/M/L | |
| Dimensions (HxWxD) | Indoor (mm) | 400x1505x980 |
| Outdoor (mm) | 1430x940x320 | |
| Weight | Indoor (kg) | 60 |
| Outdoor (kg) | 93 | |
| Power Supply | V/Hz | 1 Phase, 220-240V, 50Hz |
| Compressor Type | Hermetically Sealed Swing Type | |
| Refrigerant | R32 | |
| Pipe Sizes | Liquid (mm) | 9.5 (Flared) |
| Gas (mm) | 15.9 (Flared) | |
| Drain (mm) | ID 25 / OD 32 | |
| Supply Air Opening | mm (HxW, Flange) | 295×1152 |
| Return Air Opening | mm | 2×400 (Oval) |
| Outdoor Operating Range | Cool (ºCDB) | -5 to 50 |
| Heat (ºCWB) | -15 to 16 | |
| EPA Sound Power Level | dBA | 73 |
| Outdoor Sound Level (H) @ 1m | Pressure dBA (C/H) | 54/56 |
Reviews (0)
Specifications
| INDOOR UNIT | FDYA140AV1 | |
| OUTDOOR UNIT | RZAS140C2V1 | |
| Rated Capacity | Cool (kW) | 14.0 |
| Heat (kW) | 16.5 | |
| Capacity Range | Cool (kW) | 5.0-16.0 |
| Heat (kW) | 5.1-18.0 | |
| Power Input (Rated) | Cool (kW) | 3.93 |
| Heat (kW) | 4,28 | |
| E.E.R/C.O.P | C/H | 3.56/3.86 |
Specifications
| INDOOR UNIT | FDYA140AV1 | |
| OUTDOOR UNIT | RZAS140C2V1 | |
| Rated Capacity | Cool (kW) | 14.0 |
| Heat (kW) | 16.5 | |
| Capacity Range | Cool (kW) | 5.0-16.0 |
| Heat (kW) | 5.1-18.0 | |
| Power Input (Rated) | Cool (kW) | 3.93 |
| Heat (kW) | 4,28 | |
| E.E.R/C.O.P | C/H | 3.56/3.86 |
| TCSPF (Residential) | Hot/Average/Cold | 5.00/4.55/4.69 |
| HSPF (Residential) | Hot/Average/Cold | 4.11/3.67/3.16 |
| Airflow Rate (Nominal/Max) | l/s | 900/1000 |
| Indoor Sound Level (H) @ 1.5m | dBA (C/H) | 45.9/47.4 |
| Piping Length | m | 75 |
| Indoor Fan Speeds | H/M/L | |
| Dimensions (HxWxD) | Indoor (mm) | 400x1505x980 |
| Outdoor (mm) | 1430x940x320 | |
| Weight | Indoor (kg) | 60 |
| Outdoor (kg) | 93 | |
| Power Supply | V/Hz | 1 Phase, 220-240V, 50Hz |
| Compressor Type | Hermetically Sealed Swing Type | |
| Refrigerant | R32 | |
| Pipe Sizes | Liquid (mm) | 9.5 (Flared) |
| Gas (mm) | 15.9 (Flared) | |
| Drain (mm) | ID 25 / OD 32 | |
| Supply Air Opening | mm (HxW, Flange) | 295×1152 |
| Return Air Opening | mm | 2×400 (Oval) |
| Outdoor Operating Range | Cool (ºCDB) | -5 to 50 |
| Heat (ºCWB) | -15 to 16 | |
| EPA Sound Power Level | dBA | 73 |
| Outdoor Sound Level (H) @ 1m | Pressure dBA (C/H) | 54/56 |
Related news
Генератор випадкових чисел: як Dude Bet casino довіряє чесності
New jersey Internet casino Bet Real money on Hard rock Wager
Bet9ja Gambling enterprise 2026 Ports, Recreations Incentive and cash British
The platform work perfectly on mobile internet explorer, making it possible for pages to place bets when, everywhere
Plus incentive fund, and there is no actual barrier among them



Review DAIKIN FDYA140A-C2V 14.0kW Premium Inverter Ducted System 1 Phase