DAIKIN FDYAN160A-C2V 15.5kW Inverter Ducted Air Conditioner System 1 Phase
FDYAN160A-C2V
Price: (Inc GST)
PRODUCT INFORMATION
- Ducted Inverter One phase
- SKU: FDYAN160A-C2V / BRC1E63
- 15.5 kW Cooling/18.0 kW Heating
- DAIKIN FDYAN160A-C2V 15.5kW Inverter Ducted Air Conditioner System – 1 Phase/R32
- Includes Indoor Unit – FDYAN160AV1/Outdoor Unit – RZA160C2V1
- Available Controllers: BRC1E63 – Standard
KEY FEATURES
It’s the unique features of Daikin products that makes us the world leader.
Improved Energy Efficiency: Achieved through the use of a DC Fan motor, cross-pass heat exchanger and increased outdoor coil passes.
Compact Indoor Unit: Low profile height of ≤360mm to fit comfortably into the tight roof space of a modern home.
Space Saving Outdoor Unit: Models up to 19.5kW are encased in a space saving side discharge outdoor unit allowing for flexible placement.
Night Quiet Mode: Reduces the outdoor noise levels during sleeping hours and automatically resumes normal operations in the morning.
R22 Retrofit Capability: Provides a cost effective and convenient upgrade from an existing R22 ducted system whilst retaining the field piping (5.0-15.5kW Models).
Australian Made: Indoor units are specifically designed and manufactured to Australian standards to withstand the harsher summer climate.
Specifications
| INDOOR UNIT | FDYAN160AV1 | |
| OUTDOOR UNIT | FDYAN160AV1 | |
| Rated Capacity | Cool (kW) | 15.5 |
| Heat (kW) | 18.0 | |
| Capacity Range | Cool (kW) | 7.3-16.3 |
| Heat (kW) | 7.3-18.2 | |
| Power Input (Rated) | Cool (kW) | 4.95 |
| Heat (kW) | 4.90 | |
| E.E.R/C.O.P | C/H | 3.13/3.67 |
Specifications
| INDOOR UNIT | FDYAN160AV1 | |
| OUTDOOR UNIT | FDYAN160AV1 | |
| Rated Capacity | Cool (kW) | 15.5 |
| Heat (kW) | 18.0 | |
| Capacity Range | Cool (kW) | 7.3-16.3 |
| Heat (kW) | 7.3-18.2 | |
| Power Input (Rated) | Cool (kW) | 4.95 |
| Heat (kW) | 4.90 | |
| E.E.R/C.O.P | C/H | 3.13/3.67 |
| TCSPF (Residential) | Hot/Average/ Cold | 4.05/3.76/3.87 |
| HSPF (Residential) | Hot/Average/ Cold | 3.87/3.53/3.12 |
| Airflow Rate (Nominal/Max) | l/s | 950/1120 |
| Indoor Sound Level (H) @1.5m | dBA (C/H) | 47.9/50.7 |
| Piping Length | m | 50 |
| Indoor Fan Speeds | H/M/L | |
| Dimensions (HxWxD) | Indoor (mm) | 360x1520x935 |
| Outdoor (mm) | 1430x940x320 | |
| Weight | Indoor (kg) | 56 |
| Outdoor (kg) | 99 | |
| Power Supply | V/Hz | 1 Phase, 220-240V, 50Hz |
| Compressor Type | Hermetically Sealed Swing Type | |
| Refrigerant | R32 | |
| Pipe Sizes | Liquid (mm) | 9.5 (Flare) |
| Gas (mm) | 15.9 (Flare) | |
| Drain (mm) | ID 25 / OD 32 | |
| Supply Air Opening | mm (HxW, Flange) | 245×1152 |
| Return Air Opening | mm | 2×400 (Oval) |
| Outdoor Operating Range | Cool (ºCDB) | -5 to 46 |
| Heat (ºCWB) | -15 to 16 | |
| EPA Sound Power Level | dBA | 75 |
| Outdoor Sound Level (H) @1m | Pressure dBA (C/H) | 56/58 |
Reviews (0)
Specifications
| INDOOR UNIT | FDYAN160AV1 | |
| OUTDOOR UNIT | FDYAN160AV1 | |
| Rated Capacity | Cool (kW) | 15.5 |
| Heat (kW) | 18.0 | |
| Capacity Range | Cool (kW) | 7.3-16.3 |
| Heat (kW) | 7.3-18.2 | |
| Power Input (Rated) | Cool (kW) | 4.95 |
| Heat (kW) | 4.90 | |
| E.E.R/C.O.P | C/H | 3.13/3.67 |
Specifications
| INDOOR UNIT | FDYAN160AV1 | |
| OUTDOOR UNIT | FDYAN160AV1 | |
| Rated Capacity | Cool (kW) | 15.5 |
| Heat (kW) | 18.0 | |
| Capacity Range | Cool (kW) | 7.3-16.3 |
| Heat (kW) | 7.3-18.2 | |
| Power Input (Rated) | Cool (kW) | 4.95 |
| Heat (kW) | 4.90 | |
| E.E.R/C.O.P | C/H | 3.13/3.67 |
| TCSPF (Residential) | Hot/Average/ Cold | 4.05/3.76/3.87 |
| HSPF (Residential) | Hot/Average/ Cold | 3.87/3.53/3.12 |
| Airflow Rate (Nominal/Max) | l/s | 950/1120 |
| Indoor Sound Level (H) @1.5m | dBA (C/H) | 47.9/50.7 |
| Piping Length | m | 50 |
| Indoor Fan Speeds | H/M/L | |
| Dimensions (HxWxD) | Indoor (mm) | 360x1520x935 |
| Outdoor (mm) | 1430x940x320 | |
| Weight | Indoor (kg) | 56 |
| Outdoor (kg) | 99 | |
| Power Supply | V/Hz | 1 Phase, 220-240V, 50Hz |
| Compressor Type | Hermetically Sealed Swing Type | |
| Refrigerant | R32 | |
| Pipe Sizes | Liquid (mm) | 9.5 (Flare) |
| Gas (mm) | 15.9 (Flare) | |
| Drain (mm) | ID 25 / OD 32 | |
| Supply Air Opening | mm (HxW, Flange) | 245×1152 |
| Return Air Opening | mm | 2×400 (Oval) |
| Outdoor Operating Range | Cool (ºCDB) | -5 to 46 |
| Heat (ºCWB) | -15 to 16 | |
| EPA Sound Power Level | dBA | 75 |
| Outdoor Sound Level (H) @1m | Pressure dBA (C/H) | 56/58 |
Related news
Gold Game geschult sofortige Ein- ferner Auszahlungen weiters finden sie auf rund um ebendiese Chronometer geoffnete Alive-Lobbys
Andere Lieferant zuteil werden lassen diesseitigen Manipulation advers unter einsatz von diesseitigen mobilen Inter browser
Meinereiner genoss mein verzocktes Piepen leer Moglich Casinos nochmals einbehalten
De asemenea, poti beneficia din un bonus de bun venit Vei dori sa cand po?i prima depunere
Pereche orice pe care trebuie sa ce e?ti deja con?tient pe bonusurile in locul depunere pe cazino


Review DAIKIN FDYAN160A-C2V 15.5kW Inverter Ducted Air Conditioner System 1 Phase