DAIKIN FDYA125A-C2V 12.5kW Premium Inverter Ducted System 1 Phase
FDYA125A-C2V
Price: (Inc GST)
PRODUCT INFORMATION
- Ducted Premium Inverter one phase
- SKU: FDYA125A-C2V / BRC1E63
- 12.5 kW Cooling/15.0 kW Heating
- DAIKIN FDYA125A-C2V (Previously known: FDYA125A-CV) 12.5kW Reverse Cycle Premium Inverter Ducted Air Conditioner System 1 Phase
- Indoor Unit : FDYA125AV1
- Outdoor Unit: RZAS125C2V1 (Previously known: RZAS125CV1)
- Available Controllers
- R32 | SUPERIOR ENERGY PERFORMANCE
KEY FEATURES
It’s the unique features of Daikin products that makes us the world leader.
Industry Leading Energy Performance: Achieved with a redesigned cross-pass heat exchanger, DC fan motor and improved refrigerant control technology.
Night Quiet Mode: Reduces the outdoor noise levels during sleeping hours and automatically resumes normal operations in the morning.
Increased Operation Limits: The refrigerant cooled PCB technology incorporated in the outdoor unit enables continuous operations up to 50°CDB ambient.
Heating Focus Option: Heating Focus models are available from 18.0-24.0kW with improved heating performance, ideal for cold climates such as Canberra, Hobart & Melbourne.
R22 Retrofit Capability: Provides a cost effective and convenient upgrade from an existing R22 ducted system whilst retaining the field piping (not available for Heating Focus models).
Australian Made: Indoor units are specifically designed and manufactured to Australian standards to withstand the harsher summer climate.
Specifications
| INDOOR UNIT | FDYA125AV1 | |
| OUTDOOR UNIT | RZAS125C2V1 | |
| Rated Capacity | Cool (kW) | 12.5 |
| Heat (kW) | 15.0 | |
| Capacity Range | Cool (kW) | 5.0-14.0 |
| Heat (kW) | 5.1-16.0 | |
| Power Input (Rated) | Cool (kW) | 3.45 |
| Heat (kW) | 3.80 | |
| E.E.R/C.O.P | C/H | 3.62/3.95 |
Specifications
| INDOOR UNIT | FDYA125AV1 | |
| OUTDOOR UNIT | RZAS125C2V1 | |
| Rated Capacity | Cool (kW) | 12.5 |
| Heat (kW) | 15.0 | |
| Capacity Range | Cool (kW) | 5.0-14.0 |
| Heat (kW) | 5.1-16.0 | |
| Power Input (Rated) | Cool (kW) | 3.45 |
| Heat (kW) | 3.80 | |
| E.E.R/C.O.P | C/H | 3.62/3.95 |
| TCSPF (Residential) | Hot/Average/Cold | 4.57/4.18/4.26 |
| HSPF (Residential) | Hot/Average/Cold | 4.43/3.92/3.36 |
| Airflow Rate (Nominal/Max) | l/s | 755/840 |
| Indoor Sound Level (H) @ 1.5m | dBA (C/H) | 44.8/46.2 |
| Piping Length | m | 75 |
| Indoor Fan Speeds | H/M/L | |
| Dimensions (HxWxD) | Indoor (mm) | 360x1520x935 |
| Outdoor (mm) | 1430x940x320 | |
| Weight | Indoor (kg) | 56 |
| Outdoor (kg) | 93 | |
| Power Supply | V/Hz | 1 Phase, 220-240V, 50Hz |
| Compressor Type | Hermetically Sealed Swing Type | |
| Refrigerant | R32 | |
| Pipe Sizes | Liquid (mm) | 9.5 (Flared) |
| Gas (mm) | 15.9 (Flared) | |
| Drain (mm) | ID 25 / OD 32 | |
| Supply Air Opening | mm (HxW, Flange) | 245×1152 |
| Return Air Opening | mm | 2×400 (Oval) |
| Outdoor Operating Range | Cool (ºCDB) | -5 to 50 |
| Heat (ºCWB) | -15 to 16 | |
| EPA Sound Power Level | dBA | 71 |
| Outdoor Sound Level (H) @ 1m | Pressure dBA (C/H) | 52/54 |
Reviews (0)
Specifications
| INDOOR UNIT | FDYA125AV1 | |
| OUTDOOR UNIT | RZAS125C2V1 | |
| Rated Capacity | Cool (kW) | 12.5 |
| Heat (kW) | 15.0 | |
| Capacity Range | Cool (kW) | 5.0-14.0 |
| Heat (kW) | 5.1-16.0 | |
| Power Input (Rated) | Cool (kW) | 3.45 |
| Heat (kW) | 3.80 | |
| E.E.R/C.O.P | C/H | 3.62/3.95 |
Specifications
| INDOOR UNIT | FDYA125AV1 | |
| OUTDOOR UNIT | RZAS125C2V1 | |
| Rated Capacity | Cool (kW) | 12.5 |
| Heat (kW) | 15.0 | |
| Capacity Range | Cool (kW) | 5.0-14.0 |
| Heat (kW) | 5.1-16.0 | |
| Power Input (Rated) | Cool (kW) | 3.45 |
| Heat (kW) | 3.80 | |
| E.E.R/C.O.P | C/H | 3.62/3.95 |
| TCSPF (Residential) | Hot/Average/Cold | 4.57/4.18/4.26 |
| HSPF (Residential) | Hot/Average/Cold | 4.43/3.92/3.36 |
| Airflow Rate (Nominal/Max) | l/s | 755/840 |
| Indoor Sound Level (H) @ 1.5m | dBA (C/H) | 44.8/46.2 |
| Piping Length | m | 75 |
| Indoor Fan Speeds | H/M/L | |
| Dimensions (HxWxD) | Indoor (mm) | 360x1520x935 |
| Outdoor (mm) | 1430x940x320 | |
| Weight | Indoor (kg) | 56 |
| Outdoor (kg) | 93 | |
| Power Supply | V/Hz | 1 Phase, 220-240V, 50Hz |
| Compressor Type | Hermetically Sealed Swing Type | |
| Refrigerant | R32 | |
| Pipe Sizes | Liquid (mm) | 9.5 (Flared) |
| Gas (mm) | 15.9 (Flared) | |
| Drain (mm) | ID 25 / OD 32 | |
| Supply Air Opening | mm (HxW, Flange) | 245×1152 |
| Return Air Opening | mm | 2×400 (Oval) |
| Outdoor Operating Range | Cool (ºCDB) | -5 to 50 |
| Heat (ºCWB) | -15 to 16 | |
| EPA Sound Power Level | dBA | 71 |
| Outdoor Sound Level (H) @ 1m | Pressure dBA (C/H) | 52/54 |
Related news
Pick from one,000+ fun totally free-to-play video game and winnings amazing honors
Loyalty benefits will be unlocked because of the people who frequently come back and you will play in the a site
Key factors such as betting requirements, qualified games, and you may detachment limits can also be somewhat effect just how worthwhile a plus it really is was
?i la obtine si bonusul din bun venit, este necesar sa efectuezi un prim adere
Supported by Caesars Recreation, that it sportsbook blends top brand name recognition with at the very top perks system



Review DAIKIN FDYA125A-C2V 12.5kW Premium Inverter Ducted System 1 Phase