SAMSUNG AJ100TXJ5KH/EA 10kW Free Joint Multi Air Conditioning Outdoor Unit Only
AJ100TXJ5KH/EA
Price: (Inc GST)
PRODUCT INFORMATION
- SKU: AJ100TXJ5KH/EA
- FJM NASA, 5 ports, 10.0kW outdoor
Key Features
Control your Space
Flexible Systems
Samsung Free Joint Multi (FJM) Air Conditioning systems are designed to be flexible – allowing you to heat or cool multiple areas in your home from one air conditioning system. The space-saving FJM System consists of three main components; an outdoor unit; several compatible indoor unit(s); and controllers.* The flexibility of our FJM systems means that you can have up to 5 indoor units connected to a singular outdoor unit. They are compatible with a variety of indoor types, so you can choose the combination that is optimal for you. You can also set different temperatures on each indoor unit, giving you ultimate control.**
Experience Ultimate Comfort
Powerful, Reliable Performance
Enjoy greater efficiency and low levels of vibration for a smoother and quieter all-round performance with a twin rotary BLDC compressor. The smart compressor design and premium moving parts of the Samsung FJM air conditioning system deliver a balanced, reliable performance.
Energy Superstar
Low Running Cost
FJM NASA is a highly energy-efficient system. Digital Inverter Technology allows you to save energy and money every day with a self-adjusting system. FJM Compressors automatically adjust their speed in response to changes in room temperature, reducing energy consumption by up to 60%. For an equivalent airflow, it uses less energy*. This leads to a low running cost – meaning you can use your system all day long without a hefty bill!
Supporting a Restful Night’s Sleep
Silent Comfort
Feel more relaxed as superior insulation and low vibration combine to create a more comfortable atmosphere. The Samsung FJM NASA air conditioning system minimises noise via a Sine Wave Controller, which produces smoother vibrations as compared to traditional Square Wave Controllers. Also featuring double-layered sound insulation material, this unit operates quietly and discreetly all year round.
Fits in small places
Compact Size
The small dimensions of the FJM outdoor unit make it simple to install, meaning it can fit into more places. Models up to 10kW are less than 1m in height, units can be installed under a window – without sacrificing your view.
Covers large spaces
Multi-Port Design
Our FJM’s 5 multi-port design means that a single outdoor unit can be connected to up to five indoor units*. This means you can keep your building exterior neat while giving you the power to cool your entire home.
All round simpler & intuitive control
Controller (model MWR-WG00JN), sold separately
Intuitively control performance with our controller and know where the air is flowing at all times. The MWR-WG00JN Controller* offers functionality control – the display allows you to set an on/off countdown timer, turn on/off, and view the filter cleaning alert indicator. Other controller options are available.
Cool your home from anywhere
Wi-Fi and the SmartThings app
Specifications
Model | AJ100TXJ5KH/EA | ||
Refrigerant | R410A | ||
Power Supply | (Ø, V, Hz) | 1, 220-240, 50 | |
Rated Capacity | Cooling | (kW) | 10.0 |
Heating | (kW) | 12.0 | |
Connectable number of indoor units | Maximum | 5 | |
Efficiency ratio | EER – Cooling | 3.45 | |
COP – Heating | 4.10 |
Specifications
Model | AJ100TXJ5KH/EA | ||
Refrigerant | R410A | ||
Power Supply | (Ø, V, Hz) | 1, 220-240, 50 | |
Rated Capacity | Cooling | (kW) | 10.0 |
Heating | (kW) | 12.0 | |
Connectable number of indoor units | Maximum | 5 | |
Efficiency ratio | EER – Cooling | 3.45 | |
COP – Heating | 4.10 | ||
Current | MCA | (A) | 25.0 |
MFA | (A) | 28.8 | |
Sound Pressure | Cooling | dB(A) | 54 |
Heating | dB(A) | 55 | |
Sound Power | dB(A) | 70 | |
Piping, connections | Liquid Pipe | C, mm x EA | 6.35 x 5 |
C, inch x EA | 1/4 x 5 | ||
Gas Pipe | C, mm x EA | 9.52×2 + 12.7×3 | |
C, inch x EA | 3/8×2 + 1/2×3 | ||
Total Piping Length | (m) | 70 | |
Max. Piping length (OD to ID) | (m) | 25 | |
Max Height (ID to OD) | (m) | 15 | |
Max Height (ID to ID) | (m) | 7.5 | |
Weight | (kg) | 76.5 | |
Dimension | WxHxD | (mm) | 940 x 998 x 330 |
Operating temperature range | Cooling | °C | -10 to 46 |
Heating | °C | -15 to 24 |
Images are for illustration purposes. Product images may be different from the actual product, product sizes vary depending on the model.
Specifications may be subject to change without prior notice.
1) Capacities are based on (Equivalent refrigerant piping: 5m, Level differences: 0m).
– Cooling: Indoor temperature: 27°C DB, 19°C WB / Outdoor temperature: 35°C DB, 24°C WB.
– Heating: Indoor temperature: 20°C DB, 15°C WB / Outdoor temperature: 7°C DB, 6°C WB.
2) Select wire size based on the value of MCA.
3) Sound pressure level is obtained in an anechoic room.
– Sound pressure level is a relative value, depending on the distance and acoustic environment.
– Sound pressure level may differ depending on operation conditions.
– dBA = A-weighted sound pressure level.
– Reference acoustic pressure 0 dB = 20uPa.
4) Sound power level is an absolute value that a sound source generates.
– dBA = A-weighted sound power level.
– Reference power: 1pW.
– Measured according to ISO 3741.
5) These products contain R410A (GWP=2,088) which is fluorinated greenhouse gas.
Reviews (0)
Specifications
Model | AJ100TXJ5KH/EA | ||
Refrigerant | R410A | ||
Power Supply | (Ø, V, Hz) | 1, 220-240, 50 | |
Rated Capacity | Cooling | (kW) | 10.0 |
Heating | (kW) | 12.0 | |
Connectable number of indoor units | Maximum | 5 | |
Efficiency ratio | EER – Cooling | 3.45 | |
COP – Heating | 4.10 |
Specifications
Model | AJ100TXJ5KH/EA | ||
Refrigerant | R410A | ||
Power Supply | (Ø, V, Hz) | 1, 220-240, 50 | |
Rated Capacity | Cooling | (kW) | 10.0 |
Heating | (kW) | 12.0 | |
Connectable number of indoor units | Maximum | 5 | |
Efficiency ratio | EER – Cooling | 3.45 | |
COP – Heating | 4.10 | ||
Current | MCA | (A) | 25.0 |
MFA | (A) | 28.8 | |
Sound Pressure | Cooling | dB(A) | 54 |
Heating | dB(A) | 55 | |
Sound Power | dB(A) | 70 | |
Piping, connections | Liquid Pipe | C, mm x EA | 6.35 x 5 |
C, inch x EA | 1/4 x 5 | ||
Gas Pipe | C, mm x EA | 9.52×2 + 12.7×3 | |
C, inch x EA | 3/8×2 + 1/2×3 | ||
Total Piping Length | (m) | 70 | |
Max. Piping length (OD to ID) | (m) | 25 | |
Max Height (ID to OD) | (m) | 15 | |
Max Height (ID to ID) | (m) | 7.5 | |
Weight | (kg) | 76.5 | |
Dimension | WxHxD | (mm) | 940 x 998 x 330 |
Operating temperature range | Cooling | °C | -10 to 46 |
Heating | °C | -15 to 24 |
Images are for illustration purposes. Product images may be different from the actual product, product sizes vary depending on the model.
Specifications may be subject to change without prior notice.
1) Capacities are based on (Equivalent refrigerant piping: 5m, Level differences: 0m).
– Cooling: Indoor temperature: 27°C DB, 19°C WB / Outdoor temperature: 35°C DB, 24°C WB.
– Heating: Indoor temperature: 20°C DB, 15°C WB / Outdoor temperature: 7°C DB, 6°C WB.
2) Select wire size based on the value of MCA.
3) Sound pressure level is obtained in an anechoic room.
– Sound pressure level is a relative value, depending on the distance and acoustic environment.
– Sound pressure level may differ depending on operation conditions.
– dBA = A-weighted sound pressure level.
– Reference acoustic pressure 0 dB = 20uPa.
4) Sound power level is an absolute value that a sound source generates.
– dBA = A-weighted sound power level.
– Reference power: 1pW.
– Measured according to ISO 3741.
5) These products contain R410A (GWP=2,088) which is fluorinated greenhouse gas.
Review SAMSUNG AJ100TXJ5KH/EA 10kW Free Joint Multi Air Conditioning Outdoor Unit Only