DAIKIN FDYA140A-C2V 14.0kW Premium Inverter Ducted System 1 Phase

FDYA140A-C2V

Price: (Inc GST)

  • Daikin
  • 5 Years
  • In stock

6 Capacity. you are choosing 14-16kw

PRODUCT INFORMATION

  • Ducted Premium Inverter one phase
  • SKU: FDYA140A-C2V / BRC1E63
  • 14.0 kW Cooling/16.5 kW Heating
  • DAIKIN FDYA140A-C2V  (Previously known: FDYA140A-CV ) 14.0 kW Reverse Cycle Premium Inverter Ducted Air Conditioner System 1 Phase
  • Indoor: FDYA140AV1
  • Outdoor: RZAS140C2V1 (Previously known: RZAS140CV1)
  • Available Controllers
  • R32 | SUPERIOR ENERGY PERFORMANCE

 

KEY FEATURES

It’s the unique features of Daikin products that makes us the world leader.

Industry Leading Energy Performance: Achieved with a redesigned cross-pass heat exchanger, DC fan motor and improved refrigerant control technology.

Night Quiet Mode: Reduces the outdoor noise levels during sleeping hours and automatically resumes normal operations in the morning.

Increased Operation Limits: The refrigerant cooled PCB technology incorporated in the outdoor unit enables continuous operations up to 50°CDB ambient.

Heating Focus Option: Heating Focus models are available from 18.0-24.0kW with improved heating performance, ideal for cold climates such as Canberra, Hobart & Melbourne.

R22 Retrofit Capability: Provides a cost effective and convenient upgrade from an existing R22 ducted system whilst retaining the field piping (not available for Heating Focus models).

Australian Made: Indoor units are specifically designed and manufactured to Australian standards to withstand the harsher summer climate.

    Submit your consultation request

    Rules

    • GenuineGenuine Brand new
      100% original, original quality warranty
    • Customer Care
      Customer care
      After-sales, thoughtful support

    Specifications

    INDOOR UNIT FDYA140AV1    
    OUTDOOR UNIT RZAS140C2V1  
    Rated Capacity Cool (kW) 14.0
    Heat (kW) 16.5
    Capacity Range Cool (kW) 5.0-16.0
    Heat (kW) 5.1-18.0
    Power Input (Rated) Cool (kW) 3.93
    Heat (kW) 4,28
    E.E.R/C.O.P C/H 3.56/3.86

     

    Specifications

    INDOOR UNIT FDYA140AV1    
    OUTDOOR UNIT RZAS140C2V1  
    Rated Capacity Cool (kW) 14.0
    Heat (kW) 16.5
    Capacity Range Cool (kW) 5.0-16.0
    Heat (kW) 5.1-18.0
    Power Input (Rated) Cool (kW) 3.93
    Heat (kW) 4,28
    E.E.R/C.O.P C/H 3.56/3.86
    TCSPF (Residential) Hot/Average/Cold 5.00/4.55/4.69
    HSPF (Residential) Hot/Average/Cold 4.11/3.67/3.16
    Airflow Rate (Nominal/Max) l/s 900/1000
    Indoor Sound Level (H) @ 1.5m dBA (C/H) 45.9/47.4
    Piping Length m 75
    Indoor Fan Speeds H/M/L
    Dimensions (HxWxD) Indoor (mm) 400x1505x980
    Outdoor (mm) 1430x940x320
    Weight Indoor (kg) 60
    Outdoor (kg) 93
    Power Supply V/Hz 1 Phase, 220-240V, 50Hz
    Compressor Type Hermetically Sealed Swing Type
    Refrigerant R32
    Pipe Sizes Liquid (mm) 9.5 (Flared)
    Gas (mm) 15.9 (Flared)
    Drain (mm) ID 25 / OD 32
    Supply Air Opening mm (HxW, Flange) 295×1152
    Return Air Opening mm 2×400 (Oval)
    Outdoor Operating Range Cool (ºCDB) -5 to 50
    Heat (ºCWB) -15 to 16
    EPA Sound Power Level dBA 73
    Outdoor Sound Level (H) @ 1m Pressure dBA (C/H) 54/56

     

    X

    Reviews (0)

    Review DAIKIN FDYA140A-C2V 14.0kW Premium Inverter Ducted System 1 Phase

    5 0% | 0 reviews
    4 0% | 0 reviews
    3 0% | 0 reviews
    2 0% | 0 reviews
    1 0% | 0 reviews
    Review DAIKIN FDYA140A-C2V 14.0kW Premium Inverter Ducted System 1 Phase

    Note: For reviews to be approved, please refer to Terms & Conditions

    Specifications

    INDOOR UNIT FDYA140AV1    
    OUTDOOR UNIT RZAS140C2V1  
    Rated Capacity Cool (kW) 14.0
    Heat (kW) 16.5
    Capacity Range Cool (kW) 5.0-16.0
    Heat (kW) 5.1-18.0
    Power Input (Rated) Cool (kW) 3.93
    Heat (kW) 4,28
    E.E.R/C.O.P C/H 3.56/3.86

     

    Specifications

    INDOOR UNIT FDYA140AV1    
    OUTDOOR UNIT RZAS140C2V1  
    Rated Capacity Cool (kW) 14.0
    Heat (kW) 16.5
    Capacity Range Cool (kW) 5.0-16.0
    Heat (kW) 5.1-18.0
    Power Input (Rated) Cool (kW) 3.93
    Heat (kW) 4,28
    E.E.R/C.O.P C/H 3.56/3.86
    TCSPF (Residential) Hot/Average/Cold 5.00/4.55/4.69
    HSPF (Residential) Hot/Average/Cold 4.11/3.67/3.16
    Airflow Rate (Nominal/Max) l/s 900/1000
    Indoor Sound Level (H) @ 1.5m dBA (C/H) 45.9/47.4
    Piping Length m 75
    Indoor Fan Speeds H/M/L
    Dimensions (HxWxD) Indoor (mm) 400x1505x980
    Outdoor (mm) 1430x940x320
    Weight Indoor (kg) 60
    Outdoor (kg) 93
    Power Supply V/Hz 1 Phase, 220-240V, 50Hz
    Compressor Type Hermetically Sealed Swing Type
    Refrigerant R32
    Pipe Sizes Liquid (mm) 9.5 (Flared)
    Gas (mm) 15.9 (Flared)
    Drain (mm) ID 25 / OD 32
    Supply Air Opening mm (HxW, Flange) 295×1152
    Return Air Opening mm 2×400 (Oval)
    Outdoor Operating Range Cool (ºCDB) -5 to 50
    Heat (ºCWB) -15 to 16
    EPA Sound Power Level dBA 73
    Outdoor Sound Level (H) @ 1m Pressure dBA (C/H) 54/56

     

    0
      0
      Your cart
      Shopping cart is empty