DAIKIN FBA71B-VC2Y 7.1Kw Premium Inverter Slim-Line Ducted System | 3 Phase
FBA71B-VC2Y
Price: (Inc GST)
PRODUCT INFORMATION
- Ducted Premium Inverter Slimline Three Phase
- SKU: FBA71B-VC2Y / BRC1E63
- 7.1 kW Cooling
- 8.0 kW Heating
- DAIKIN FBA71B-VC2Y 7.1Kw Premium Inverter Slim-Line Ducted System | 3 Phase
- (Old System Number: FBA71B-VCY)
- Indoor Unit: FBA71BVMA
- Outdoor Unit: RZAV71C2Y1 (Old System Number: RZAV71CY1)
- Included: BRC1E63 – Standard Controller
KEY FEATURES
Slim-Line Indoor: Industry leading low profile design of 245mm height ensures clearance in most narrow roof spaces.
Design Flexibility: DC fan with an static pressure of 150Pa and up to 85m (100-140 Class) of available pipe run to suit your design layout.
R22 Retrofit Capability: Provides a cost effective and convenient upgrade from an existing R22 ducted system whilst retaining the field piping.
Automatic Airflow Adjustment: Allows the fan speed to adjust automatically to suit your duct design for optimum airflow distribution.
Flexible Return Air: Option of a rear or bottom suction return allows for greater installation flexibility.
Built-in condensate pump: DC condensate pump is equipped as standard with a 850mm lift.
Specifications
| SERIES | PREMIUM INVERTER Three phase | |
| Indoor Unit | FBA71BVMA | |
| Outdoor Unit | RZAV71C2Y1 | |
| Rated Capacity | Cool (kW) | 7.1 |
| Heat (kW) | 8.0 | |
| Capacity Range | Cool (kW) | 3.2-8.0 |
| Heat (kW) | 3.5-9.0 | |
| Power Input (Rated) | Cool (kW) | 2.02 |
| Heat (kW) | 1.99 | |
| E.E.R/C.O.P | C/H | 3.51/4.02 |
Specifications
| SERIES | PREMIUM INVERTER Three phase | |
| Indoor Unit | FBA71BVMA | |
| Outdoor Unit | RZAV71C2Y1 | |
| Rated Capacity | Cool (kW) | 7.1 |
| Heat (kW) | 8.0 | |
| Capacity Range | Cool (kW) | 3.2-8.0 |
| Heat (kW) | 3.5-9.0 | |
| Power Input (Rated) | Cool (kW) | 2.02 |
| Heat (kW) | 1.99 | |
| E.E.R/C.O.P | C/H | 3.51/4.02 |
| TCSPF (Residential) | Hot/Average/Cold | 4.52/3.99/4.02 |
| HSPF (Residential) | Hot/Average/Cold | 4.49/4.14/3.71 |
| Airflow Rate (Nominal) | l/s | 383 |
| Indoor Sound Level (H) @1.5m | dBA | 38 |
| Piping Length | m | 75 |
| Indoor Fan Speeds | H/M/L | |
| Dimensions (HxWxD) | Indoor (mm) | 245x1000x800 |
| Outdoor (mm) | 990x940x320 | |
| Weight | Indoor (kg) | 37 |
| Outdoor (kg) | 69 | |
| Power Supply | V/Hz | 3 Phase, 380-415V, 50Hz |
| Compressor Type | Hermetically Sealed Swing Type | |
| Refrigerant | R32 | |
| Pipe Sizes | Liquid (mm) | 9.5 (Flared) |
| Gas (mm) | 15.9 (Flared) | |
| Drain (mm) | ID 25 / OD 32 | |
| Supply Air Opening | mm (HxW, Flange) | 176×792 |
| Return Air Opening | mm (HxW, Flange) | 208×952 |
| Outdoor Operating Range | Cool (ºCDB) | -5 to 50 |
| Heat (ºCWB) | -15 to 16 | |
| EPA Sound Power Level | dBA | 67 |
| Outdoor Sound Level (H) @1m | Pressure dBA (C/H) | 48/50 |
Reviews (0)
Specifications
| SERIES | PREMIUM INVERTER Three phase | |
| Indoor Unit | FBA71BVMA | |
| Outdoor Unit | RZAV71C2Y1 | |
| Rated Capacity | Cool (kW) | 7.1 |
| Heat (kW) | 8.0 | |
| Capacity Range | Cool (kW) | 3.2-8.0 |
| Heat (kW) | 3.5-9.0 | |
| Power Input (Rated) | Cool (kW) | 2.02 |
| Heat (kW) | 1.99 | |
| E.E.R/C.O.P | C/H | 3.51/4.02 |
Specifications
| SERIES | PREMIUM INVERTER Three phase | |
| Indoor Unit | FBA71BVMA | |
| Outdoor Unit | RZAV71C2Y1 | |
| Rated Capacity | Cool (kW) | 7.1 |
| Heat (kW) | 8.0 | |
| Capacity Range | Cool (kW) | 3.2-8.0 |
| Heat (kW) | 3.5-9.0 | |
| Power Input (Rated) | Cool (kW) | 2.02 |
| Heat (kW) | 1.99 | |
| E.E.R/C.O.P | C/H | 3.51/4.02 |
| TCSPF (Residential) | Hot/Average/Cold | 4.52/3.99/4.02 |
| HSPF (Residential) | Hot/Average/Cold | 4.49/4.14/3.71 |
| Airflow Rate (Nominal) | l/s | 383 |
| Indoor Sound Level (H) @1.5m | dBA | 38 |
| Piping Length | m | 75 |
| Indoor Fan Speeds | H/M/L | |
| Dimensions (HxWxD) | Indoor (mm) | 245x1000x800 |
| Outdoor (mm) | 990x940x320 | |
| Weight | Indoor (kg) | 37 |
| Outdoor (kg) | 69 | |
| Power Supply | V/Hz | 3 Phase, 380-415V, 50Hz |
| Compressor Type | Hermetically Sealed Swing Type | |
| Refrigerant | R32 | |
| Pipe Sizes | Liquid (mm) | 9.5 (Flared) |
| Gas (mm) | 15.9 (Flared) | |
| Drain (mm) | ID 25 / OD 32 | |
| Supply Air Opening | mm (HxW, Flange) | 176×792 |
| Return Air Opening | mm (HxW, Flange) | 208×952 |
| Outdoor Operating Range | Cool (ºCDB) | -5 to 50 |
| Heat (ºCWB) | -15 to 16 | |
| EPA Sound Power Level | dBA | 67 |
| Outdoor Sound Level (H) @1m | Pressure dBA (C/H) | 48/50 |
Related news
Attract Expected! Cloudflare
Game Container 999 Internet casino Totally free APK Download to own Android
Welches ist ihr haufigste Boden fur jedes abgelehnte Auszahlungsanfragen hinein Freispiel-Erwerben ohne Einzahlung
D. h., sic Welche hierbei die eine reguliertere Spielumgebung auffinden, wobei auslandische Moglich Casinos kleiner reguliert werden
Mindesteinzahlung, Umsatzbedingungen, Auszahlungslimits, Handhabung weiters Kundenbetreuung in besitz sein von deshalb ohne ausnahme mit bei diesseitigen Kollationieren


Review DAIKIN FBA71B-VC2Y 7.1Kw Premium Inverter Slim-Line Ducted System | 3 Phase