DAIKIN FBA140B-VF2Y 14.0kW Premium Inverter Slim-Line Ducted System | 3 Phase
FBA140B-VF2Y
Price: (Inc GST)
PRODUCT INFORMATION
- Ducted Premium Inverter Slimline Three Phase
- SKU: FBA140B-VF2Y / BRC1E63
- 14.0 kW Cooling
- 16.0 kW Heating
- DAIKIN FBA140B-VF2Y 14.0kW Premium Inverter Slim-Line Ducted System | 3 Phase
- (Old System Number: FBA140B-VFY)
- Indoor Unit: FBA140BVMA
- Outdoor Unit: RZAV140F2Y1 (Old System Number: RZAV140FY1)
- Included: BRC1E63 – Standard Controller
KEY FEATURES
Slim-Line Indoor: Industry leading low profile design of 245mm height ensures clearance in most narrow roof spaces.
Design Flexibility: DC fan with an static pressure of 150Pa and up to 85m (100-140 Class) of available pipe run to suit your design layout.
R22 Retrofit Capability: Provides a cost effective and convenient upgrade from an existing R22 ducted system whilst retaining the field piping.
Automatic Airflow Adjustment: Allows the fan speed to adjust automatically to suit your duct design for optimum airflow distribution.
Flexible Return Air: Option of a rear or bottom suction return allows for greater installation flexibility.
Built-in condensate pump: DC condensate pump is equipped as standard with a 850mm lift.
Specifications
| SERIES | PREMIUM INVERTER Three phase | |
| Indoor Unit | FBA140BVMA | |
| Outdoor Unit | RZAV140F2Y1 | |
| Rated Capacity | Cool (kW) | 14.0 |
| Heat (kW) | 16.5 | |
| Capacity Range | Cool (kW) | 3.5-15.0 |
| Heat (kW) | 3.5-18.0 | |
| Power Input (Rated) | Cool (kW) | 4.28 |
| Heat (kW) | 4.52 | |
| E.E.R/C.O.P | C/H | 3.27/3.65 |
Specifications
| SERIES | PREMIUM INVERTER Three phase | |
| Indoor Unit | FBA140BVMA | |
| Outdoor Unit | RZAV140F2Y1 | |
| Rated Capacity | Cool (kW) | 14.0 |
| Heat (kW) | 16.5 | |
| Capacity Range | Cool (kW) | 3.5-15.0 |
| Heat (kW) | 3.5-18.0 | |
| Power Input (Rated) | Cool (kW) | 4.28 |
| Heat (kW) | 4.52 | |
| E.E.R/C.O.P | C/H | 3.27/3.65 |
| TCSPF (Residential) | Hot/Average/Cold | 4.91/4.54/4.71 |
| HSPF (Residential) | Hot/Average/Cold | 5.24/4.35/3.77 |
| Airflow Rate (Nominal) | l/s | 600 |
| Indoor Sound Level (H) @1.5m | dBA | 40 |
| Piping Length | m | 85 |
| Indoor Fan Speeds | H/M/L | |
| Dimensions (HxWxD) | Indoor (mm) | 245x1400x800 |
| Outdoor (mm) | 870x1100x460 | |
| Weight | Indoor (kg) | 47 |
| Outdoor (kg) | 95 | |
| Power Supply | V/Hz | 3 Phase, 380-415V, 50Hz |
| Compressor Type | Hermetically Sealed Swing Type | |
| Refrigerant | R32 | |
| Pipe Sizes | Liquid (mm) | 9.5 (Flared) |
| Gas (mm) | 15.9 (Flared) | |
| Drain (mm) | ID 25 / OD 32 | |
| Supply Air Opening | mm (HxW, Flange) | 176×1192 |
| Return Air Opening | mm (HxW, Flange) | 208×1352 |
| Outdoor Operating Range | Cool (ºCDB) | -5 to 50 |
| Heat (ºCWB) | -15 to 16 | |
| EPA Sound Power Level | dBA | 70 |
| Outdoor Sound Level (H) @1m | Pressure dBA (C/H) | 52/53 |
Reviews (0)
Specifications
| SERIES | PREMIUM INVERTER Three phase | |
| Indoor Unit | FBA140BVMA | |
| Outdoor Unit | RZAV140F2Y1 | |
| Rated Capacity | Cool (kW) | 14.0 |
| Heat (kW) | 16.5 | |
| Capacity Range | Cool (kW) | 3.5-15.0 |
| Heat (kW) | 3.5-18.0 | |
| Power Input (Rated) | Cool (kW) | 4.28 |
| Heat (kW) | 4.52 | |
| E.E.R/C.O.P | C/H | 3.27/3.65 |
Specifications
| SERIES | PREMIUM INVERTER Three phase | |
| Indoor Unit | FBA140BVMA | |
| Outdoor Unit | RZAV140F2Y1 | |
| Rated Capacity | Cool (kW) | 14.0 |
| Heat (kW) | 16.5 | |
| Capacity Range | Cool (kW) | 3.5-15.0 |
| Heat (kW) | 3.5-18.0 | |
| Power Input (Rated) | Cool (kW) | 4.28 |
| Heat (kW) | 4.52 | |
| E.E.R/C.O.P | C/H | 3.27/3.65 |
| TCSPF (Residential) | Hot/Average/Cold | 4.91/4.54/4.71 |
| HSPF (Residential) | Hot/Average/Cold | 5.24/4.35/3.77 |
| Airflow Rate (Nominal) | l/s | 600 |
| Indoor Sound Level (H) @1.5m | dBA | 40 |
| Piping Length | m | 85 |
| Indoor Fan Speeds | H/M/L | |
| Dimensions (HxWxD) | Indoor (mm) | 245x1400x800 |
| Outdoor (mm) | 870x1100x460 | |
| Weight | Indoor (kg) | 47 |
| Outdoor (kg) | 95 | |
| Power Supply | V/Hz | 3 Phase, 380-415V, 50Hz |
| Compressor Type | Hermetically Sealed Swing Type | |
| Refrigerant | R32 | |
| Pipe Sizes | Liquid (mm) | 9.5 (Flared) |
| Gas (mm) | 15.9 (Flared) | |
| Drain (mm) | ID 25 / OD 32 | |
| Supply Air Opening | mm (HxW, Flange) | 176×1192 |
| Return Air Opening | mm (HxW, Flange) | 208×1352 |
| Outdoor Operating Range | Cool (ºCDB) | -5 to 50 |
| Heat (ºCWB) | -15 to 16 | |
| EPA Sound Power Level | dBA | 70 |
| Outdoor Sound Level (H) @1m | Pressure dBA (C/H) | 52/53 |
Related news
Unsrige Chance-Engine pruft Geratschaft, IP weiters Tempo, damit samtliche seltsamen Aktivitaten dahinter feststellen, die soeben passieren
Weiteren Wettanbieter & dieses Casino konnen wir heute gar nicht raten
Sofern eingod concerning gold and silver coins spielbank aktionscodekorrekt eingegeben unter anderem nachfolgende Bedingungen erfullt man sagt, sie seien (z
Eltern im griff haben dasselbe Bankkonto in Einem Telefonappar , Device unter anderem Elektronische datenverarbeitungsanlage applizieren
Diese durfen jedoch nach herausragenden Bedingungen weiters uber ein landerspezifischen Erlaubniskarte angeboten werden


Review DAIKIN FBA140B-VF2Y 14.0kW Premium Inverter Slim-Line Ducted System | 3 Phase