DAIKIN FDYA125A-C2V 12.5kW Premium Inverter Ducted System 1 Phase
FDYA125A-C2V
Price: (Inc GST)
PRODUCT INFORMATION
- Ducted Premium Inverter one phase
- SKU: FDYA125A-C2V / BRC1E63
- 12.5 kW Cooling/15.0 kW Heating
- DAIKIN FDYA125A-C2V (Previously known: FDYA125A-CV) 12.5kW Reverse Cycle Premium Inverter Ducted Air Conditioner System 1 Phase
- Indoor Unit : FDYA125AV1
- Outdoor Unit: RZAS125C2V1 (Previously known: RZAS125CV1)
- Available Controllers
- R32 | SUPERIOR ENERGY PERFORMANCE
KEY FEATURES
It’s the unique features of Daikin products that makes us the world leader.
Industry Leading Energy Performance: Achieved with a redesigned cross-pass heat exchanger, DC fan motor and improved refrigerant control technology.
Night Quiet Mode: Reduces the outdoor noise levels during sleeping hours and automatically resumes normal operations in the morning.
Increased Operation Limits: The refrigerant cooled PCB technology incorporated in the outdoor unit enables continuous operations up to 50°CDB ambient.
Heating Focus Option: Heating Focus models are available from 18.0-24.0kW with improved heating performance, ideal for cold climates such as Canberra, Hobart & Melbourne.
R22 Retrofit Capability: Provides a cost effective and convenient upgrade from an existing R22 ducted system whilst retaining the field piping (not available for Heating Focus models).
Australian Made: Indoor units are specifically designed and manufactured to Australian standards to withstand the harsher summer climate.
Specifications
| INDOOR UNIT | FDYA125AV1 | |
| OUTDOOR UNIT | RZAS125C2V1 | |
| Rated Capacity | Cool (kW) | 12.5 |
| Heat (kW) | 15.0 | |
| Capacity Range | Cool (kW) | 5.0-14.0 |
| Heat (kW) | 5.1-16.0 | |
| Power Input (Rated) | Cool (kW) | 3.45 |
| Heat (kW) | 3.80 | |
| E.E.R/C.O.P | C/H | 3.62/3.95 |
Specifications
| INDOOR UNIT | FDYA125AV1 | |
| OUTDOOR UNIT | RZAS125C2V1 | |
| Rated Capacity | Cool (kW) | 12.5 |
| Heat (kW) | 15.0 | |
| Capacity Range | Cool (kW) | 5.0-14.0 |
| Heat (kW) | 5.1-16.0 | |
| Power Input (Rated) | Cool (kW) | 3.45 |
| Heat (kW) | 3.80 | |
| E.E.R/C.O.P | C/H | 3.62/3.95 |
| TCSPF (Residential) | Hot/Average/Cold | 4.57/4.18/4.26 |
| HSPF (Residential) | Hot/Average/Cold | 4.43/3.92/3.36 |
| Airflow Rate (Nominal/Max) | l/s | 755/840 |
| Indoor Sound Level (H) @ 1.5m | dBA (C/H) | 44.8/46.2 |
| Piping Length | m | 75 |
| Indoor Fan Speeds | H/M/L | |
| Dimensions (HxWxD) | Indoor (mm) | 360x1520x935 |
| Outdoor (mm) | 1430x940x320 | |
| Weight | Indoor (kg) | 56 |
| Outdoor (kg) | 93 | |
| Power Supply | V/Hz | 1 Phase, 220-240V, 50Hz |
| Compressor Type | Hermetically Sealed Swing Type | |
| Refrigerant | R32 | |
| Pipe Sizes | Liquid (mm) | 9.5 (Flared) |
| Gas (mm) | 15.9 (Flared) | |
| Drain (mm) | ID 25 / OD 32 | |
| Supply Air Opening | mm (HxW, Flange) | 245×1152 |
| Return Air Opening | mm | 2×400 (Oval) |
| Outdoor Operating Range | Cool (ºCDB) | -5 to 50 |
| Heat (ºCWB) | -15 to 16 | |
| EPA Sound Power Level | dBA | 71 |
| Outdoor Sound Level (H) @ 1m | Pressure dBA (C/H) | 52/54 |
Reviews (0)
Specifications
| INDOOR UNIT | FDYA125AV1 | |
| OUTDOOR UNIT | RZAS125C2V1 | |
| Rated Capacity | Cool (kW) | 12.5 |
| Heat (kW) | 15.0 | |
| Capacity Range | Cool (kW) | 5.0-14.0 |
| Heat (kW) | 5.1-16.0 | |
| Power Input (Rated) | Cool (kW) | 3.45 |
| Heat (kW) | 3.80 | |
| E.E.R/C.O.P | C/H | 3.62/3.95 |
Specifications
| INDOOR UNIT | FDYA125AV1 | |
| OUTDOOR UNIT | RZAS125C2V1 | |
| Rated Capacity | Cool (kW) | 12.5 |
| Heat (kW) | 15.0 | |
| Capacity Range | Cool (kW) | 5.0-14.0 |
| Heat (kW) | 5.1-16.0 | |
| Power Input (Rated) | Cool (kW) | 3.45 |
| Heat (kW) | 3.80 | |
| E.E.R/C.O.P | C/H | 3.62/3.95 |
| TCSPF (Residential) | Hot/Average/Cold | 4.57/4.18/4.26 |
| HSPF (Residential) | Hot/Average/Cold | 4.43/3.92/3.36 |
| Airflow Rate (Nominal/Max) | l/s | 755/840 |
| Indoor Sound Level (H) @ 1.5m | dBA (C/H) | 44.8/46.2 |
| Piping Length | m | 75 |
| Indoor Fan Speeds | H/M/L | |
| Dimensions (HxWxD) | Indoor (mm) | 360x1520x935 |
| Outdoor (mm) | 1430x940x320 | |
| Weight | Indoor (kg) | 56 |
| Outdoor (kg) | 93 | |
| Power Supply | V/Hz | 1 Phase, 220-240V, 50Hz |
| Compressor Type | Hermetically Sealed Swing Type | |
| Refrigerant | R32 | |
| Pipe Sizes | Liquid (mm) | 9.5 (Flared) |
| Gas (mm) | 15.9 (Flared) | |
| Drain (mm) | ID 25 / OD 32 | |
| Supply Air Opening | mm (HxW, Flange) | 245×1152 |
| Return Air Opening | mm | 2×400 (Oval) |
| Outdoor Operating Range | Cool (ºCDB) | -5 to 50 |
| Heat (ºCWB) | -15 to 16 | |
| EPA Sound Power Level | dBA | 71 |
| Outdoor Sound Level (H) @ 1m | Pressure dBA (C/H) | 52/54 |
Related news
Very if or not you love to continue something traditional otherwise searching for to own new things, you will be safeguarded
Step into Ahmedabad’s charm with stays designed around you at Hotel Marigold
Test Post Created
Uitgebreide_toegang_tot_online_gokken_via_westaces-casinos_nl_biedt_eindeloze_mo
The new local casino will process withdrawal needs in 24 hours or less, even in the event this schedule is not always came across according to user opinions



Review DAIKIN FDYA125A-C2V 12.5kW Premium Inverter Ducted System 1 Phase