Key Feature
- Self Clean Function
- Timer On/Off
- 7-Day Scheduler / Weekly timer: Optional
- Dehumidification
- Multi-Directional Airflow Up – Down, Left – Right: Automatic
- Hydrophilic Aluminium Coil Protection: Indoor and Outdoor
- Louvre Memory
- 6 Demand Response: Ready
- Indoor Fan Speed: 12-Speed
- Outdoor Fan Speed: 5-Speed
- Quiet Mode
- Auto Restart After Power Failure
- Fault Alarm Output Port: Optional
- Third-party inputs: Optional
- Remote On/Off: Optional
- Left-Right Hand Drain Connection
- Mute Operation
Specifications
| OUTDOOR MODEL | WRC-035CS | |
| INDOOR MODEL | WRE-035CS | |
| Net (Rated) Capacity (kW) (AS/NZS3823.1.1) | Cooling (min – max) | 3.50 (1.50 – 4.90) |
| Heating (min – max) | 3.70 (1.80 – 5.10) | |
| Input Power (kW) (AS/NZS3823.1.1) | Cooling Rated | 0.73 |
| Heating Rated | 0.77 | |
Specifications
| OUTDOOR MODEL | WRC-035CS | |||
| INDOOR MODEL | WRE-035CS | |||
| Nett (Rated) Capacity (kW) (AS/NZS3823.1.1) | Cooling (min-max) | 3.50 (1.50 – 4.90) | ||
| Heating (min-max) | 3.70 (1.80 – 5.10) | |||
| Input Power (kW) (AS/NZS3823.1.1) | Cooling Rated | 0.73 | ||
| Heating Rated | 0.77 | |||
| 1 EER Rated (AS/NZS3823.1.1) 2 COP Rated (AS/NZS3823.1.1) |
Cooling Rated | 4.79 | ||
| Heating Rated | 4.81 | |||
| Star Rating (AS/NZS3823.1.1) Hot/Average/Cold | Cooling | 5.5 star/5 star/5.5 star | ||
| Heating | 4 star/3.5 star/2.5 star | |||
| Power Supply – (V / Ph / Hz) | Outdoor | 220 – 240 V / 1Ph+N / 50Hz | ||
| Rated Load Amps (AS/NZS3823.1.1) | Cooling | 3.2 | ||
| Heating | 3.4 | |||
| Full Load Amps (AS/NZS3823.1.1) | 10.5 | |||
| Circuit Breaker Amps | 10.0 | |||
| Suggested Minimum Mains Cable Size | 1.0mm2 | |||
| Suggested Minimum Indoor to Outdoor Cable Size & Type | Size | 1.0mm2 | ||
| Type | 3 Core + Earth | |||
| IP Rating | Outdoor | IP24 | ||
| Indoor | IP20 | |||
| Moisture Removal (L/hr) | 1.7 | |||
| Compressor | Inverter Rotary | |||
| Refrigerant | R-32 | |||
| Airflow Range Indoor (l/s) | Boost | 250 | ||
| High | 180 | |||
| Medium | 120 | |||
| Low | 100 | |||
| Outdoor Dimensions (mm) | Depth | 333 | ||
| Height | 554 | |||
| Width | 805 | |||
| Indoor Dimensions (mm) | Depth | 225 | ||
| Height | 295 | |||
| Width | 795 | |||
| Nominal Weight (kgs) | Outdoor | 32.1 | ||
| Indoor | 10.3 | |||
| 4 Indoor Sound Pressure Level (dBA) | (SI/Low / Med / High) | 24 / 30 / 32 / 38 | ||
| 4 Outdoor Sound Pressure Level (dBA) 1m | 52 | |||
| 5 Outdoor Sound Power Level (dBA) | 58 | |||
| Outdoor Operating Range (°C) | Cooling | -15°C to 60°C | ||
| Heating | -25°C to 30°C | |||
| MEPS Certified | Yes | |||
| Field Piping and Connections | ||||
| Refrigerant | Factory Charge – (g) | 900 | ||
| Pre-Charge Length – (m) | 15 | |||
| Additional Refrigerant Charge – (g/m) | 12 | |||
| Minimum Field Pipe Length – (m) | 3 | |||
| Maximum Field Pipe Length – (m) | 25 | |||
| Maximum Vertical | 10 | |||
| Field Pipe Size | Liquid Pipe – mm (inch) | 6.35 (1/4) | ||
| Gas Pipe – mm (inch) | 9.52 (3/8) | |||
| Outdoor Unit | Liquid Pipe – mm (inch) | 6.35 (1/4) | ||
| Gas Pipe – mm (inch) | 9.52 (3/8) | |||
| Indoor Unit | Liquid Pipe – mm (inch) | 6.35 (1/4) | ||
| Gas Pipe – mm (inch) | 9.52 (3/8) | |||
| Wiring Method | Hardwire to Outdoor | |||
| 3 Core + Earth | ||||
Foot Notes 1-6
1. EER Rated = Energy Efficiency Ratio (Rated Capacity Cooling / Rated Input Cooling).
2. COP Rated = Coefficient of
3. Refer to AS/NZS 3000
4. Sound pressure levels are determined in an anechoic chamber and may differ once the unit is installed due to ambient conditions.
5. Measured based on EN 12102-1, Determination of the sound power level for Air conditioners.
Important Notes:
• The Local Electricity Supply Authority may require limits on – starting current, running current, and voltage drop, please check prior to purchase.
• When the outdoor temperature exceeds the rated conditions, the cooling/heating capacities may decrease the rated net values.
• Specifications are subject to change without notice.
Rated Conditions:
Cooling: 35°C DB Outdoor / Air Entering Indoor 27°C DB, 19°C WB
Heating: 7°C DB, 6°C WB Outdoor / Air Entering Indoor 20°C DB
Reviews (0)
Specifications
| OUTDOOR MODEL | WRC-035CS | |
| INDOOR MODEL | WRE-035CS | |
| Net (Rated) Capacity (kW) (AS/NZS3823.1.1) | Cooling (min – max) | 3.50 (1.50 – 4.90) |
| Heating (min – max) | 3.70 (1.80 – 5.10) | |
| Input Power (kW) (AS/NZS3823.1.1) | Cooling Rated | 0.73 |
| Heating Rated | 0.77 | |
Specifications
| OUTDOOR MODEL | WRC-035CS | |||
| INDOOR MODEL | WRE-035CS | |||
| Nett (Rated) Capacity (kW) (AS/NZS3823.1.1) | Cooling (min-max) | 3.50 (1.50 – 4.90) | ||
| Heating (min-max) | 3.70 (1.80 – 5.10) | |||
| Input Power (kW) (AS/NZS3823.1.1) | Cooling Rated | 0.73 | ||
| Heating Rated | 0.77 | |||
| 1 EER Rated (AS/NZS3823.1.1) 2 COP Rated (AS/NZS3823.1.1) |
Cooling Rated | 4.79 | ||
| Heating Rated | 4.81 | |||
| Star Rating (AS/NZS3823.1.1) Hot/Average/Cold | Cooling | 5.5 star/5 star/5.5 star | ||
| Heating | 4 star/3.5 star/2.5 star | |||
| Power Supply – (V / Ph / Hz) | Outdoor | 220 – 240 V / 1Ph+N / 50Hz | ||
| Rated Load Amps (AS/NZS3823.1.1) | Cooling | 3.2 | ||
| Heating | 3.4 | |||
| Full Load Amps (AS/NZS3823.1.1) | 10.5 | |||
| Circuit Breaker Amps | 10.0 | |||
| Suggested Minimum Mains Cable Size | 1.0mm2 | |||
| Suggested Minimum Indoor to Outdoor Cable Size & Type | Size | 1.0mm2 | ||
| Type | 3 Core + Earth | |||
| IP Rating | Outdoor | IP24 | ||
| Indoor | IP20 | |||
| Moisture Removal (L/hr) | 1.7 | |||
| Compressor | Inverter Rotary | |||
| Refrigerant | R-32 | |||
| Airflow Range Indoor (l/s) | Boost | 250 | ||
| High | 180 | |||
| Medium | 120 | |||
| Low | 100 | |||
| Outdoor Dimensions (mm) | Depth | 333 | ||
| Height | 554 | |||
| Width | 805 | |||
| Indoor Dimensions (mm) | Depth | 225 | ||
| Height | 295 | |||
| Width | 795 | |||
| Nominal Weight (kgs) | Outdoor | 32.1 | ||
| Indoor | 10.3 | |||
| 4 Indoor Sound Pressure Level (dBA) | (SI/Low / Med / High) | 24 / 30 / 32 / 38 | ||
| 4 Outdoor Sound Pressure Level (dBA) 1m | 52 | |||
| 5 Outdoor Sound Power Level (dBA) | 58 | |||
| Outdoor Operating Range (°C) | Cooling | -15°C to 60°C | ||
| Heating | -25°C to 30°C | |||
| MEPS Certified | Yes | |||
| Field Piping and Connections | ||||
| Refrigerant | Factory Charge – (g) | 900 | ||
| Pre-Charge Length – (m) | 15 | |||
| Additional Refrigerant Charge – (g/m) | 12 | |||
| Minimum Field Pipe Length – (m) | 3 | |||
| Maximum Field Pipe Length – (m) | 25 | |||
| Maximum Vertical | 10 | |||
| Field Pipe Size | Liquid Pipe – mm (inch) | 6.35 (1/4) | ||
| Gas Pipe – mm (inch) | 9.52 (3/8) | |||
| Outdoor Unit | Liquid Pipe – mm (inch) | 6.35 (1/4) | ||
| Gas Pipe – mm (inch) | 9.52 (3/8) | |||
| Indoor Unit | Liquid Pipe – mm (inch) | 6.35 (1/4) | ||
| Gas Pipe – mm (inch) | 9.52 (3/8) | |||
| Wiring Method | Hardwire to Outdoor | |||
| 3 Core + Earth | ||||
Foot Notes 1-6
1. EER Rated = Energy Efficiency Ratio (Rated Capacity Cooling / Rated Input Cooling).
2. COP Rated = Coefficient of
3. Refer to AS/NZS 3000
4. Sound pressure levels are determined in an anechoic chamber and may differ once the unit is installed due to ambient conditions.
5. Measured based on EN 12102-1, Determination of the sound power level for Air conditioners.
Important Notes:
• The Local Electricity Supply Authority may require limits on – starting current, running current, and voltage drop, please check prior to purchase.
• When the outdoor temperature exceeds the rated conditions, the cooling/heating capacities may decrease the rated net values.
• Specifications are subject to change without notice.
Rated Conditions:
Cooling: 35°C DB Outdoor / Air Entering Indoor 27°C DB, 19°C WB
Heating: 7°C DB, 6°C WB Outdoor / Air Entering Indoor 20°C DB







Review ActronAir Serene 2 WRE-035CS 3.5kW Inverter Reverse Cycle Wall Split System Single Phase