ActronAir LRE-071CS/LRC-071CS 7.1kW Ultra Slim Low Profile Inverter Split Ducted System Single Phase
LRE-071CS / LRC-071CS
Price: (Inc GST)
- SKU: LRE-071CS / LRC-071CS
- Cooling: 7.3 kW
- Heating: 7.7 kW
- LRE-071CS LOW PROFILE DUCTED RC INDOOR UNIT 7.1KW GEN C 1PH R32
- LRC-071CS RC OUTDOOR UNIT 7.1KW GEN C 1PH R32
- Premium Wired Controller Included
- Built In Drain Pump Included
Key Features
Wired Wall Controller | WC-02 | |
Follow Me Function | Yes | |
Sleep | Yes | |
Turbo | Yes | |
Auto Defrost Function | Yes | |
Timer On/Off | Yes | |
7-Day Scheduler / Weekly timer | Yes | |
Dehumidification (Dry Mode) | Yes | |
Return Air Sensor | Yes | |
External Static Pressure Settings | Yes | |
Drain Pump | Yes | |
Bottom Return Air Connection | Optional | |
Outside Air Intake | Optional | |
Hanging Brackets | Yes | |
Hydrophilic Aluminium Coil Protection | Indoor | Yes |
Outdoor | Yes | |
Demand Response | Ready | |
Indoor Fan Speed | 4-Speed | |
Outdoor Fan Speed | 5-Speed | |
Auto Restart Auto Power Failure | Yes | |
Fault Alarm Output Port | Yes | |
Remote On/Off | Yes | |
Left-Right Hand Drain Connection – Gravity Fed | Yes | |
Easyconnect Wi-Fi App | Optional |
Specifications
OUTDOOR MODEL | LRC-071CS | |
INDOOR MODEL | LRE-071CS | |
Nett (Rated) Capacity (kW) (AS/NZS3823.1.2) | Cooling (min-max) | 7.30 (2.80 – 8.40) |
Heating (min-max) | 7.70 (3.00 – 9.00) | |
Input Power (kW) (AS/NZS3823.1.2) | Cooling Rated | 2.06 |
Heating Rated | 1.73 | |
1 EER Rated (AS/NZS3823.1.2) 2 COP Rated (AS/NZS3823.1.2) |
Cooling Rated | 3.54 |
Heating Rated | 4.45 |
Specifications
OUTDOOR MODEL | LRC-071CS | |
INDOOR MODEL | LRE-071CS | |
Net (Rated) Capacity (kW) (AS/NZS3823.1.2) | Cooling (min-max) | 7.30 (2.80 – 8.40) |
Heating (min-max) | 7.70 (3.00 – 9.00) | |
Input Power (kW) (AS/NZS3823.1.2) | Cooling Rated | 2.06 |
Heating Rated | 1.73 | |
1 EER Rated (AS/NZS3823.1.2) 2 COP Rated (AS/NZS3823.1.2) |
Cooling Rated | 3.54 |
Heating Rated | 4.45 | |
Power Supply – (V / Ph / Hz) | Outdoor | 220 – 240 V / 1Ph+N / 50Hz |
Rated Load Amps (AS/NZS3823.1.2) | Cooling | 9.1 |
Heating | 7.4 | |
Full Load Amps (AS/NZS3823.1.2) | 16.0 | |
Circuit Breaker Amps | 20.0 | |
3 Suggested Minimum Mains Cable Size | 2.5mm2 | |
3 Suggested Minimum Indoor to Outdoor Power Cable Size & Type | 1.0mm2 2 Core + Earth |
|
IP Rating | Outdoor | IP24 |
Indoor | IPX0 | |
Compressor | Inverter Twin-Rotary | |
Refrigerant | R32 | |
Airflow Range Indoor (l/s) | High | 450 |
Medium | 370 | |
Low | 300 | |
External Static Pressure Range (Pa) | 0 to 160 | |
Airflow l/s | (Min / Nom / Max) | 280 / 390 / 500 |
Outdoor Dimensions (mm) | Depth | 342 |
Height | 673 | |
Width | 890 | |
Indoor Dimensions (mm) | Depth | 774 |
Height | 249 | |
Width | 1100 | |
4 Nominal Weight (kgs) | Outdoor | 45 |
Indoor | 31.6 | |
Indoor Sound Pressure Level (dBA) | (Low / Med / High) | 38.5 / 35.5 / 32.5 |
5 Outdoor Sound Pressure Level (dBA) 1m | 60 | |
6 Outdoor Sound Power Level (dBA) | 65 | |
Outdoor Operating Range (°C) | Cooling | -15°C to 50°C |
Heating | -25°C to 30°C | |
Dry | 0°C to 50°C | |
MEPS Certified | Yes | |
Field Piping and Connections | ||
Refrigerant Charge | Factory Charge – (g) | 1750 |
Pre-Charge Length – (m) | 20 | |
Additional Refrigerant Charge – (g/m) | 24 | |
Minimum Field Pipe Length – (m) | 3 | |
Maximum Field Pipe Length – (m) | 50 | |
Maximum Vertical Height Differential (m) included in max length | 30 | |
Field Pipe Size | Liquid Pipe – mm (inch) | 9.52 (3/8) |
Gas Pipe – mm (inch) | 15.9 (5/8) | |
Outdoor Unit | Liquid Pipe – mm (inch) | 9.52 (3/8) |
Gas Pipe – mm (inch) | 15.9 (5/8) | |
Indoor Unit | Liquid Pipe – mm (inch) | 9.52 (3/8) |
Gas Pipe – mm (inch) | 15.9 (5/8) | |
Wiring Method | Hardwire to Outdoor | |
Interconnect Data Cable | 2 Core 14/0.20 (0.44m2) Shielded | |
Interconnect Power Cable | 2 Core + Earth |
Foot Notes 1-7
1. EER Rated = Energy Efficiency Ratio (Rated Capacity Cooling¸ Rated Input Power Cooling)
2. COP Rated = Coefficient of Performance (Rated Capacity Heating¸ Rated Power Heating)
3. Refer to AS/NZS 3000 ‘Australian/New Zealand Wiring Rules’ for more details.
4. Refer to the Catalogue Unit Weight Distribution Guide section for details of weight points.
5. Sound Pressure Level at 1m distance is determined as the measured sound pressure at 1m perpendicular to the coil side of the condenser.
6. Determination of Sound Power Levels of Noise Sources, AS1217.2 – Precision Methods for Broad-Band Sources in Reverberation Rooms.
7. When the Demand Response capability option is chosen, the air conditioner will be fully compliant with AS4755.3 in the following modes: DRM 1, 2, 3
Important Notes:
• The Local Electricity Supply Authority may require limits on – starting current, running current, and voltage drop, please check before purchase.
• When the outdoor temperature exceeds the rated conditions, the cooling/heating capacities may decrease the rated net values.
• Specifications are subject to change without notice.
Rated Conditions:
Cooling: 35°C DB Outdoor / Air Entering Indoor 27°C DB, 19°C WB Heating: 7°C DB, 6°C WB Outdoor / Air Entering Indoor 20°C DB
Warranty:
For full terms and conditions of the ActronAir warranty, please refer to the warranty terms document
– www.actronair.com.au
Reviews (0)
Specifications
OUTDOOR MODEL | LRC-071CS | |
INDOOR MODEL | LRE-071CS | |
Nett (Rated) Capacity (kW) (AS/NZS3823.1.2) | Cooling (min-max) | 7.30 (2.80 – 8.40) |
Heating (min-max) | 7.70 (3.00 – 9.00) | |
Input Power (kW) (AS/NZS3823.1.2) | Cooling Rated | 2.06 |
Heating Rated | 1.73 | |
1 EER Rated (AS/NZS3823.1.2) 2 COP Rated (AS/NZS3823.1.2) |
Cooling Rated | 3.54 |
Heating Rated | 4.45 |
Specifications
OUTDOOR MODEL | LRC-071CS | |
INDOOR MODEL | LRE-071CS | |
Net (Rated) Capacity (kW) (AS/NZS3823.1.2) | Cooling (min-max) | 7.30 (2.80 – 8.40) |
Heating (min-max) | 7.70 (3.00 – 9.00) | |
Input Power (kW) (AS/NZS3823.1.2) | Cooling Rated | 2.06 |
Heating Rated | 1.73 | |
1 EER Rated (AS/NZS3823.1.2) 2 COP Rated (AS/NZS3823.1.2) |
Cooling Rated | 3.54 |
Heating Rated | 4.45 | |
Power Supply – (V / Ph / Hz) | Outdoor | 220 – 240 V / 1Ph+N / 50Hz |
Rated Load Amps (AS/NZS3823.1.2) | Cooling | 9.1 |
Heating | 7.4 | |
Full Load Amps (AS/NZS3823.1.2) | 16.0 | |
Circuit Breaker Amps | 20.0 | |
3 Suggested Minimum Mains Cable Size | 2.5mm2 | |
3 Suggested Minimum Indoor to Outdoor Power Cable Size & Type | 1.0mm2 2 Core + Earth |
|
IP Rating | Outdoor | IP24 |
Indoor | IPX0 | |
Compressor | Inverter Twin-Rotary | |
Refrigerant | R32 | |
Airflow Range Indoor (l/s) | High | 450 |
Medium | 370 | |
Low | 300 | |
External Static Pressure Range (Pa) | 0 to 160 | |
Airflow l/s | (Min / Nom / Max) | 280 / 390 / 500 |
Outdoor Dimensions (mm) | Depth | 342 |
Height | 673 | |
Width | 890 | |
Indoor Dimensions (mm) | Depth | 774 |
Height | 249 | |
Width | 1100 | |
4 Nominal Weight (kgs) | Outdoor | 45 |
Indoor | 31.6 | |
Indoor Sound Pressure Level (dBA) | (Low / Med / High) | 38.5 / 35.5 / 32.5 |
5 Outdoor Sound Pressure Level (dBA) 1m | 60 | |
6 Outdoor Sound Power Level (dBA) | 65 | |
Outdoor Operating Range (°C) | Cooling | -15°C to 50°C |
Heating | -25°C to 30°C | |
Dry | 0°C to 50°C | |
MEPS Certified | Yes | |
Field Piping and Connections | ||
Refrigerant Charge | Factory Charge – (g) | 1750 |
Pre-Charge Length – (m) | 20 | |
Additional Refrigerant Charge – (g/m) | 24 | |
Minimum Field Pipe Length – (m) | 3 | |
Maximum Field Pipe Length – (m) | 50 | |
Maximum Vertical Height Differential (m) included in max length | 30 | |
Field Pipe Size | Liquid Pipe – mm (inch) | 9.52 (3/8) |
Gas Pipe – mm (inch) | 15.9 (5/8) | |
Outdoor Unit | Liquid Pipe – mm (inch) | 9.52 (3/8) |
Gas Pipe – mm (inch) | 15.9 (5/8) | |
Indoor Unit | Liquid Pipe – mm (inch) | 9.52 (3/8) |
Gas Pipe – mm (inch) | 15.9 (5/8) | |
Wiring Method | Hardwire to Outdoor | |
Interconnect Data Cable | 2 Core 14/0.20 (0.44m2) Shielded | |
Interconnect Power Cable | 2 Core + Earth |
Foot Notes 1-7
1. EER Rated = Energy Efficiency Ratio (Rated Capacity Cooling¸ Rated Input Power Cooling)
2. COP Rated = Coefficient of Performance (Rated Capacity Heating¸ Rated Power Heating)
3. Refer to AS/NZS 3000 ‘Australian/New Zealand Wiring Rules’ for more details.
4. Refer to the Catalogue Unit Weight Distribution Guide section for details of weight points.
5. Sound Pressure Level at 1m distance is determined as the measured sound pressure at 1m perpendicular to the coil side of the condenser.
6. Determination of Sound Power Levels of Noise Sources, AS1217.2 – Precision Methods for Broad-Band Sources in Reverberation Rooms.
7. When the Demand Response capability option is chosen, the air conditioner will be fully compliant with AS4755.3 in the following modes: DRM 1, 2, 3
Important Notes:
• The Local Electricity Supply Authority may require limits on – starting current, running current, and voltage drop, please check before purchase.
• When the outdoor temperature exceeds the rated conditions, the cooling/heating capacities may decrease the rated net values.
• Specifications are subject to change without notice.
Rated Conditions:
Cooling: 35°C DB Outdoor / Air Entering Indoor 27°C DB, 19°C WB Heating: 7°C DB, 6°C WB Outdoor / Air Entering Indoor 20°C DB
Warranty:
For full terms and conditions of the ActronAir warranty, please refer to the warranty terms document
– www.actronair.com.au
Review ActronAir LRE-071CS/LRC-071CS 7.1kW Ultra Slim Low Profile Inverter Split Ducted System Single Phase