ActronAir LRE-1140CS/LRC-140CS 14.0 kW Ultra Slim Low Profile Inverter Split Ducted System Single Phase

LRE-140 CS/LRC-140 CS

Price: (Inc GST)

  • ActronAir
  • 5 Years
  • In stock

4 capacity. you are choosing 14-16kw

  • SKU: LRE-140 CS / LRC-140 CS
  • Cooling: 14.0 kW
  • Heating: 14.35 kW
  • LRE-140 CS LOW PROFILE DUCTED RC INDOOR UNIT 14.0 KW GEN C 1PH R32
  • LRC-140 CS RC OUTDOOR UNIT 14.35 KW GEN C 1PH R32
  • Premium Wired Controller Included
  • Built In Drain Pump Included

 

Key Features

Wired Wall Controller WC-02
Follow Me Function Yes
Sleep Yes
Turbo Yes
Auto Defrost Function Yes
Timer On/Off Yes
7-Day Scheduler / Weekly timer Yes
Dehumidification (Dry Mode) Yes
Return Air Sensor Yes
External Static Pressure Settings Yes
Drain Pump Yes
Bottom Return Air Connection Optional
Outside Air Intake Optional
Hanging Brackets Yes
Hydrophilic Aluminium Coil Protection Indoor Yes
Outdoor Yes
Demand Response Ready
Indoor Fan Speed 4-Speed
Outdoor Fan Speed 5-Speed
Auto Restart Auto Power Failure Yes
Fault Alarm Output Port Yes
Remote On/Off Yes
Left-Right Hand Drain Connection – Gravity Fed Yes
Easy connect Wi-Fi App Optional

    Submit your consultation request

    Rules

    • GenuineGenuine Brand new
      100% original, original quality warranty
    • Customer Care
      Customer care
      After-sales, thoughtful support

    Specifications

    OUTDOOR MODEL LRC-140CS
    INDOOR MODEL LRE-140CS
    Nett (Rated) Capacity (kW) (AS/NZS3823.1.2) Cooling (min-max) 14.00 (5.60 – 16.00)
    Heating (min-max) 14.35 (6.40 – 18.00)
    Input Power (kW) (AS/NZS3823.1.2) Cooling Rated 4.11
    Heating Rated 3.46
    1 EER Rated (AS/NZS3823.1.2)
    2 COP Rated (AS/NZS3823.1.2)
    Cooling Rated 3.41
    Heating Rated 4.15

    Specifications

    OUTDOOR MODEL LRC-140CS
    INDOOR MODEL LRE-140CS
    Net (Rated) Capacity (kW) (AS/NZS3823.1.2) Cooling (min-max) 14.00 (5.60 – 16.00)
    Heating (min-max) 14.35 (6.40 – 18.00)
    Input Power (kW) (AS/NZS3823.1.2) Cooling Rated 4.11
    Heating Rated 3.46
    1 EER Rated (AS/NZS3823.1.2)
    2 COP Rated (AS/NZS3823.1.2)
    Cooling Rated 3.41
    Heating Rated 4.15
    Power Supply – (V / Ph / Hz) Outdoor 220 – 240 V / 1Ph+N / 50Hz
    Rated Load Amps (AS/NZS3823.1.2) Cooling 18.1
    Heating 15.6
    Full Load Amps (AS/NZS3823.1.2) 31.0
    Circuit Breaker Amps 32.0
    3 Suggested Minimum Mains Cable Size 6.0mm2
    3 Suggested Minimum Indoor to Outdoor Power Cable Size & Type 1.0mm2
    2 Core + Earth
    IP Rating Outdoor IP14
    Indoor IPX0
    Compressor Inverter Twin-Rotary
    Refrigerant R32
    Airflow Range Indoor (l/s) High 875
    Medium 730
    Low 585
    External Static Pressure Range (Pa) 0 to 200
    Airflow l/s (Min / Nom / Max) 550 / 750 / 950
    Outdoor Dimensions (mm) Depth 415
    Height 1333
    Width 952
    Indoor Dimensions (mm) Depth 625
    Height 380
    Width 1200
    4 Nominal Weight (kgs) Outdoor 95.1
    Indoor 53.3
    Indoor Sound Pressure Level (dBA) (Low / Med / High) 46.5 / 43.5 / 40.0
    5 Outdoor Sound Pressure Level (dBA) 1m 60
    6 Outdoor Sound Power Level (dBA) 71
    Outdoor Operating Range (°C) Cooling -15°C to 50°C
    Heating -25°C to 30°C
    Dry 0°C to 50°C
    MEPS Certified Yes
    Field Piping and Connections  
    Refrigerant Charge Factory Charge – (g)  
    Pre-Charge Length – (m) 20
    Additional Refrigerant Charge – (g/m) 24
    Minimum Field Pipe Length – (m) 3
    Maximum Field Pipe Length – (m) 75
    Maximum Vertical Height Differential (m) included in max length 30
    Field Pipe Size Liquid Pipe – mm (inch) 9.52 (3/8)
    Gas Pipe – mm (inch) 15.9 (5/8)
    Outdoor Unit Liquid Pipe – mm (inch) 9.52 (3/8)
    Gas Pipe – mm (inch) 15.9 (5/8)
    Indoor Unit Liquid Pipe – mm (inch) 9.52 (3/8)
    Gas Pipe – mm (inch) 15.9 (5/8)
    Wiring Method Hardwire to Outdoor
    Interconnect Data Cable 2 Core 14/0.20 (0.44m2) Shielded
    Interconnect Power Cable 2 Core + Earth

    Foot Notes 1-7
    1. EER Rated = Energy Efficiency Ratio (Rated Capacity Cooling¸ Rated Input Power Cooling)
    2. COP Rated = Coefficient of Performance (Rated Capacity Heating¸ Rated Power Heating)
    3. Refer to AS/NZS 3000 ‘Australian/New Zealand Wiring Rules’ for more details.
    4. Refer to the Catalogue Unit Weight Distribution Guide section for details of weight points.
    5. Sound Pressure Level at 1m distance is determined as the measured sound pressure at 1m perpendicular to the coil side of the condenser.
    6. Determination of Sound Power Levels of Noise Sources, AS1217.2 – Precision Methods for Broad-Band Sources in Reverberation Rooms.
    7. When the Demand Response capability option is chosen, the air conditioner will be fully compliant with AS4755.3 in the following modes: DRM 1, 2, 3

    Important Notes:
    • The Local Electricity Supply Authority may require limits on – starting current, running current, and voltage drop, please check before purchase.
    • When the outdoor temperature exceeds the rated conditions, the cooling/heating capacities may decrease the rated net values.
    • Specifications are subject to change without notice.
    Rated Conditions:
    Cooling: 35°C DB Outdoor / Air Entering Indoor 27°C DB, 19°C WB Heating: 7°C DB, 6°C WB Outdoor / Air Entering Indoor 20°C DB
    Warranty:
    For full terms and conditions of the ActronAir warranty, please refer to the warranty terms document
    – www.actronair.com.au

    X

    Reviews (0)

    Review ActronAir LRE-1140CS/LRC-140CS 14.0 kW Ultra Slim Low Profile Inverter Split Ducted System Single Phase

    5 0% | 0 reviews
    4 0% | 0 reviews
    3 0% | 0 reviews
    2 0% | 0 reviews
    1 0% | 0 reviews
    Review ActronAir LRE-1140CS/LRC-140CS 14.0 kW Ultra Slim Low Profile Inverter Split Ducted System Single Phase

    Note: For reviews to be approved, please refer to Terms & Conditions

    Specifications

    OUTDOOR MODEL LRC-140CS
    INDOOR MODEL LRE-140CS
    Nett (Rated) Capacity (kW) (AS/NZS3823.1.2) Cooling (min-max) 14.00 (5.60 – 16.00)
    Heating (min-max) 14.35 (6.40 – 18.00)
    Input Power (kW) (AS/NZS3823.1.2) Cooling Rated 4.11
    Heating Rated 3.46
    1 EER Rated (AS/NZS3823.1.2)
    2 COP Rated (AS/NZS3823.1.2)
    Cooling Rated 3.41
    Heating Rated 4.15

    Specifications

    OUTDOOR MODEL LRC-140CS
    INDOOR MODEL LRE-140CS
    Net (Rated) Capacity (kW) (AS/NZS3823.1.2) Cooling (min-max) 14.00 (5.60 – 16.00)
    Heating (min-max) 14.35 (6.40 – 18.00)
    Input Power (kW) (AS/NZS3823.1.2) Cooling Rated 4.11
    Heating Rated 3.46
    1 EER Rated (AS/NZS3823.1.2)
    2 COP Rated (AS/NZS3823.1.2)
    Cooling Rated 3.41
    Heating Rated 4.15
    Power Supply – (V / Ph / Hz) Outdoor 220 – 240 V / 1Ph+N / 50Hz
    Rated Load Amps (AS/NZS3823.1.2) Cooling 18.1
    Heating 15.6
    Full Load Amps (AS/NZS3823.1.2) 31.0
    Circuit Breaker Amps 32.0
    3 Suggested Minimum Mains Cable Size 6.0mm2
    3 Suggested Minimum Indoor to Outdoor Power Cable Size & Type 1.0mm2
    2 Core + Earth
    IP Rating Outdoor IP14
    Indoor IPX0
    Compressor Inverter Twin-Rotary
    Refrigerant R32
    Airflow Range Indoor (l/s) High 875
    Medium 730
    Low 585
    External Static Pressure Range (Pa) 0 to 200
    Airflow l/s (Min / Nom / Max) 550 / 750 / 950
    Outdoor Dimensions (mm) Depth 415
    Height 1333
    Width 952
    Indoor Dimensions (mm) Depth 625
    Height 380
    Width 1200
    4 Nominal Weight (kgs) Outdoor 95.1
    Indoor 53.3
    Indoor Sound Pressure Level (dBA) (Low / Med / High) 46.5 / 43.5 / 40.0
    5 Outdoor Sound Pressure Level (dBA) 1m 60
    6 Outdoor Sound Power Level (dBA) 71
    Outdoor Operating Range (°C) Cooling -15°C to 50°C
    Heating -25°C to 30°C
    Dry 0°C to 50°C
    MEPS Certified Yes
    Field Piping and Connections  
    Refrigerant Charge Factory Charge – (g)  
    Pre-Charge Length – (m) 20
    Additional Refrigerant Charge – (g/m) 24
    Minimum Field Pipe Length – (m) 3
    Maximum Field Pipe Length – (m) 75
    Maximum Vertical Height Differential (m) included in max length 30
    Field Pipe Size Liquid Pipe – mm (inch) 9.52 (3/8)
    Gas Pipe – mm (inch) 15.9 (5/8)
    Outdoor Unit Liquid Pipe – mm (inch) 9.52 (3/8)
    Gas Pipe – mm (inch) 15.9 (5/8)
    Indoor Unit Liquid Pipe – mm (inch) 9.52 (3/8)
    Gas Pipe – mm (inch) 15.9 (5/8)
    Wiring Method Hardwire to Outdoor
    Interconnect Data Cable 2 Core 14/0.20 (0.44m2) Shielded
    Interconnect Power Cable 2 Core + Earth

    Foot Notes 1-7
    1. EER Rated = Energy Efficiency Ratio (Rated Capacity Cooling¸ Rated Input Power Cooling)
    2. COP Rated = Coefficient of Performance (Rated Capacity Heating¸ Rated Power Heating)
    3. Refer to AS/NZS 3000 ‘Australian/New Zealand Wiring Rules’ for more details.
    4. Refer to the Catalogue Unit Weight Distribution Guide section for details of weight points.
    5. Sound Pressure Level at 1m distance is determined as the measured sound pressure at 1m perpendicular to the coil side of the condenser.
    6. Determination of Sound Power Levels of Noise Sources, AS1217.2 – Precision Methods for Broad-Band Sources in Reverberation Rooms.
    7. When the Demand Response capability option is chosen, the air conditioner will be fully compliant with AS4755.3 in the following modes: DRM 1, 2, 3

    Important Notes:
    • The Local Electricity Supply Authority may require limits on – starting current, running current, and voltage drop, please check before purchase.
    • When the outdoor temperature exceeds the rated conditions, the cooling/heating capacities may decrease the rated net values.
    • Specifications are subject to change without notice.
    Rated Conditions:
    Cooling: 35°C DB Outdoor / Air Entering Indoor 27°C DB, 19°C WB Heating: 7°C DB, 6°C WB Outdoor / Air Entering Indoor 20°C DB
    Warranty:
    For full terms and conditions of the ActronAir warranty, please refer to the warranty terms document
    – www.actronair.com.au

    0
      0
      Your cart