Samsung S2 10.0kW AC100TNHDKG/SA Inverter Ducted system R32, 1 phase

AC100TNHDKG/SA

Price: (Inc GST)

  • Samsung
  • 5 Years
  • In stock

4 Capacity. you are choosing 10-12kw

PRODUCT INFORMATION

  • 10.0 kW Cooling
  • 11.2 kW Heating
  • Indoor: AC100TNHDKG/SA 10.0kW Duct S2 split indoor, R32
  • Outdoor:  AC100TXAPKG/SA 10.0kW Universal outdoor (Duct S2, Cassettes) R32
  • Controller: MWR-WE13N Local Controller, wired, NASA

 

KEY FEATURES

The Samsung Duct S2 has a powerful airflow that allows for quick cooling in any place. The Duct S2 system has the capacity to cool you when you need it most. Along with two fans in the Samsung S2 5.2kW model and three fans in the 7.1kW-14kW versions.

Lightweight and simple to set up

With its lightweight and compact inside the unit, the Duct S2 design makes installation simple. Larger capacity units (16kW and up) are readily detachable for easier carrying and installation in the spaces where you face restrictions. The Duct S2’s indoor components are likewise short in height. Also, making it easier to install in roof areas.

Features of Samsung S2:

  • Twin BLCD compressor and auto ESP.
  • Demand Response Enabled Device (D.R.E.D)
  • 3-way service access
  • Digital Inverter Technology

Twin BLCD compressor and auto ESP

Due to its Twin BLCD compressor with auto ESP, Samsung’s duct system heats and cools your space promptly and maintains adequate air volume automatically. Operating in locations with outside temperatures ranging from -15°C to +50°C for cooling and -20°C to +24°C for heating will provide excellent comfort in any Australian setting.

Demand Response Enabled Device (D.R.E.D)

Certain energy providers can employ D.R.E.D. to limit your power use during peak demand periods, lowering the load on the power grid. Participation may entitle you to rebates from your energy provider; contact your provider for further information and to determine if it recognizes D.R.E.D.

D.R.E.D. is supported by all Samsung Ducted systems, with DRM1, DRM2, and DRM3 levels.

3-way service access

The removable panels on three sides of the Duct S2 make maintenance easier than before.

Digital Inverter Technology

Unlike traditional fixed-speed compressors, which regularly shut down and restart during operation, the compressor automatically adjusts its speed in response to variations in room temperature and user settings. This technology ensures maximum comfort by maintaining the correct temperature with little fluctuations while also optimizing power utilization, lowering energy consumption and running costs.

Please contact us for additional information about this product

    Submit your consultation request

    Rules

    • GenuineGenuine Brand new
      100% original, original quality warranty
    • Customer Care
      Customer care
      After-sales, thoughtful support

    Specifications

    Model Name System Indoor unit
    Outdoor unit
    AC100TNHDKG/SA                    
    AC100TXAPKG/SA 
    Capacity Refrigerant R32
    Cooling (Min/Std/Max) kW 4.3 / 10.0 / 12.0
    Heating (Min/Std/Max) kW 3.6 / 11.2 / 16.0
    Efficiency Energy grade (Cooling) EER 3.70
    Energy grade (Heating) COP 4.10
    Energy grade (Cooling) AEER 3.69
    Energy grade (Heating) ACOP 4.09

    Specifications

    Model Name System Indoor unit
    Outdoor unit
    AC100TNHDKG/SA                    
    AC100TXAPKG/SA 
    Capacity Refrigerant R32
    Cooling (Min/Std/Max) kW 4.3 / 10.0 / 12.0
    Heating (Min/Std/Max) kW 3.6 / 11.2 / 16.0
    Efficiency Energy grade (Cooling) EER 3.70
    Energy grade (Heating) COP 4.10
    Energy grade (Cooling) AEER 3.69
    Energy grade (Heating) ACOP 4.09
    Electrical MCA A 26.7
    MFA A 30
    Indoor Unit Power supply Ф, #, V, Hz 1-phase, 220-240V, 50Hz
    Airflow rate (H, M, L) l/s 650 / 550 / 450
    ESP (L,M,H) Pa 29 / 49 / 196
    Sound pressure @ 1.5m (H/L) dB(A) 42 / 37 / 32
    Supply air opening (WxH) mm 1268 x 270
    Return air opening (WxH) mm 1268 x 270
    Net weight kg 43.5
    Unit dimensions (WxHxD) mm 1300 x 300 x 700
    Drain connection size mm OD 32 / ID 25
    Drain pump (sold separately) MDP-G075SP (external type), MDP-G075SQ (internal type)
    Outdoor Unit Power supply Ф, #, V, Hz 1-phase, 220-240V, 50Hz
    Type Rotary
    Sound pressure @ 1m (Cool/Heat) dB(A) 51 / 53
    Sound power (Cooling – High) dB(A) 68
    Net weight kg 97.5
    Shipping weight kg 106.5
    Net dimensions (WxHxD) mm 940 x 1420 x 330
    Shipping dimensions (WxHxD) mm 995 x 1598 x 426
    Installation Liquid pipe 9.52, 3/8”
    Gas pipe 15.8, 5/8”
    Max. allowable piping length m 85
    Max. allowable piping height (outdoor above indoor) m 30
    Pre-charged length m 30
    Operating Range Cooling °C -15~50
    Heating °C -20~24

     

    X

    Reviews (0)

    Review Samsung S2 10.0kW AC100TNHDKG/SA Inverter Ducted system R32, 1 phase

    5 0% | 0 reviews
    4 0% | 0 reviews
    3 0% | 0 reviews
    2 0% | 0 reviews
    1 0% | 0 reviews
    Review Samsung S2 10.0kW AC100TNHDKG/SA Inverter Ducted system R32, 1 phase

    Note: For reviews to be approved, please refer to Terms & Conditions

    Specifications

    Model Name System Indoor unit
    Outdoor unit
    AC100TNHDKG/SA                    
    AC100TXAPKG/SA 
    Capacity Refrigerant R32
    Cooling (Min/Std/Max) kW 4.3 / 10.0 / 12.0
    Heating (Min/Std/Max) kW 3.6 / 11.2 / 16.0
    Efficiency Energy grade (Cooling) EER 3.70
    Energy grade (Heating) COP 4.10
    Energy grade (Cooling) AEER 3.69
    Energy grade (Heating) ACOP 4.09

    Specifications

    Model Name System Indoor unit
    Outdoor unit
    AC100TNHDKG/SA                    
    AC100TXAPKG/SA 
    Capacity Refrigerant R32
    Cooling (Min/Std/Max) kW 4.3 / 10.0 / 12.0
    Heating (Min/Std/Max) kW 3.6 / 11.2 / 16.0
    Efficiency Energy grade (Cooling) EER 3.70
    Energy grade (Heating) COP 4.10
    Energy grade (Cooling) AEER 3.69
    Energy grade (Heating) ACOP 4.09
    Electrical MCA A 26.7
    MFA A 30
    Indoor Unit Power supply Ф, #, V, Hz 1-phase, 220-240V, 50Hz
    Airflow rate (H, M, L) l/s 650 / 550 / 450
    ESP (L,M,H) Pa 29 / 49 / 196
    Sound pressure @ 1.5m (H/L) dB(A) 42 / 37 / 32
    Supply air opening (WxH) mm 1268 x 270
    Return air opening (WxH) mm 1268 x 270
    Net weight kg 43.5
    Unit dimensions (WxHxD) mm 1300 x 300 x 700
    Drain connection size mm OD 32 / ID 25
    Drain pump (sold separately) MDP-G075SP (external type), MDP-G075SQ (internal type)
    Outdoor Unit Power supply Ф, #, V, Hz 1-phase, 220-240V, 50Hz
    Type Rotary
    Sound pressure @ 1m (Cool/Heat) dB(A) 51 / 53
    Sound power (Cooling – High) dB(A) 68
    Net weight kg 97.5
    Shipping weight kg 106.5
    Net dimensions (WxHxD) mm 940 x 1420 x 330
    Shipping dimensions (WxHxD) mm 995 x 1598 x 426
    Installation Liquid pipe 9.52, 3/8”
    Gas pipe 15.8, 5/8”
    Max. allowable piping length m 85
    Max. allowable piping height (outdoor above indoor) m 30
    Pre-charged length m 30
    Operating Range Cooling °C -15~50
    Heating °C -20~24

     

    0
      0
      Your cart
      Shopping cart is empty