Samsung S2 10kW AC100TNHDKG/SA, AC100TXAPNG/SA Inverter Ducted system R32, 3 phase
AC100TNHDKG/SA, AC100TXAPNG/SA
Price: (Inc GST)
PRODUCT INFORMATION
- 16.0 kW Cooling
- 18 kW Heating
- Indoor – AC160TNHFKG/SA 16.0kW Duct S2, Split table indoor, R32
- Outdoor – AC160TXAPKG/SA 16.0kW Universal outdoor 1 Phase (Duct S2/S2+, Cassettes) R32
- Controller : MWR-WE13N Local Controller, wired, NASA
KEY FEATURES
The Samsung Duct S2 has a powerful airflow that allows for quick cooling in any place. The Duct S2 system has the capacity to cool you when you need it most. Along with two fans in the Samsung S2 5.2kW model and three fans in the 7.1kW-14kW versions.
Lightweight and simple to set up
With its lightweight and compact inside the unit, the Duct S2 design makes installation simple. Larger capacity units (16kW and up) are readily detachable for easier carrying and installation in the spaces where you face restrictions. The Duct S2’s indoor components are likewise short in height. Also, making it easier to install in roof areas.
Features of Samsung S2:
- Twin BLCD compressor and auto ESP.
- Demand Response Enabled Device (D.R.E.D)
- 3-way service access
- Digital Inverter Technology
Twin BLCD compressor and auto ESP
Due to its Twin BLCD compressor with auto ESP, Samsung’s duct system heats and cools your space promptly and maintains adequate air volume automatically. Operating in locations with outside temperatures ranging from -15°C to +50°C for cooling and -20°C to +24°C for heating will provide excellent comfort in any Australian setting.
Demand Response Enabled Device (D.R.E.D)
Certain energy providers can employ D.R.E.D. to limit your power use during peak demand periods, lowering the load on the power grid. Participation may entitle you to rebates from your energy provider; contact your provider for further information and to determine if it recognizes D.R.E.D.
D.R.E.D. is supported by all Samsung Ducted systems, with DRM1, DRM2, and DRM3 levels.
3-way service access
The removable panels on three sides of the Duct S2 make maintenance easier than before.
Digital Inverter Technology
Unlike traditional fixed-speed compressors, which regularly shut down and restart during operation, the compressor automatically adjusts its speed in response to variations in room temperature and user settings. This technology ensures maximum comfort by maintaining the correct temperature with little fluctuations while also optimizing power utilization, lowering energy consumption and running costs.
Please contact us for additional information about this product
Specifications
Model Name System | Indoor unit Outdoor unit |
AC100TNHDKG/SA AC100TXAPNG/SA |
|
Capacity | Refrigerant | R32 | |
Cooling (Min/Std/Max) | kW | 43/10/12 | |
Heating (Min/Std/Max) | kW | 3.6/11.2/16 | |
Efficiency | Energy grade (Cooling) | EER | 3.7 |
Energy grade (Heating) | COP | 4.1 | |
Energy grade (Cooling) | AEER | 3.69 | |
Energy grade (Heating) | ACOP | 4.09 |
Specifications
Model Name System | Indoor unit Outdoor unit |
AC100TNHDKG/SA AC100TXAPNG/SA |
|
Capacity | Refrigerant | R32 | |
Cooling (Min/Std/Max) | kW | 43/10/12 | |
Heating (Min/Std/Max) | kW | 3.6/11.2/16 | |
Efficiency | Energy grade (Cooling) | EER | 3.7 |
Energy grade (Heating) | COP | 4.1 | |
Energy grade (Cooling) | AEER | 3.69 | |
Energy grade (Heating) | ACOP | 4.09 | |
Electrical | MCA | A | 18.8 |
MFA | A | 18.8 | |
Indoor Unit | Power supply | Ф, #, V, Hz | 3 Phase, 380-415v, 50Hz |
Airflow rate (H, M, L) | l/s | 650/550/450 | |
ESP (L,M,H) | Pa | 29/49/196 | |
Sound pressure @ 1.5m (H/L) | dB(A) | 42/37/32 | |
Supply air opening (WxH) | mm | 1268X270 | |
Return air opening (WxH) | mm | 1268X270 | |
Net weight | kg | 43.5 | |
Unit dimensions (WxHxD) | mm | 1300 x 300 x 700 | |
Drain connection size | mm | OD 32 / ID 25 | |
Drain pump (sold separately) | MDP-G075SP (external type), MDP-G075SQ (internal type) | ||
Outdoor Unit | Power supply | Ф, #, V, Hz | 3 Phase, 380-415v, 50Hz |
Type | Rotary | ||
Sound pressure @ 1m (Cool/Heat) | dB(A) | 51/53 | |
Sound power (Cooling – High) | dB(A) | 68 | |
Net weight | kg | 97.5 | |
Shipping weight | kg | 106.5 | |
Net dimensions (WxHxD) | mm | 940 x 1420 x 330 | |
Shipping dimensions (WxHxD) | mm | 995 x 1598 x 426 | |
Installation | Liquid pipe | 9.52, 3/8” | |
Gas pipe | 15.8, 5/8” | ||
Max. allowable piping length | m | 85 | |
Max. allowable piping height (outdoor above indoor) | m | 30 | |
Pre-charged length | m | 30 | |
Operating Range | Cooling | °C | -15 to 50 |
Heating | °C | -20 to 24 |
Reviews (0)
Specifications
Model Name System | Indoor unit Outdoor unit |
AC100TNHDKG/SA AC100TXAPNG/SA |
|
Capacity | Refrigerant | R32 | |
Cooling (Min/Std/Max) | kW | 43/10/12 | |
Heating (Min/Std/Max) | kW | 3.6/11.2/16 | |
Efficiency | Energy grade (Cooling) | EER | 3.7 |
Energy grade (Heating) | COP | 4.1 | |
Energy grade (Cooling) | AEER | 3.69 | |
Energy grade (Heating) | ACOP | 4.09 |
Specifications
Model Name System | Indoor unit Outdoor unit |
AC100TNHDKG/SA AC100TXAPNG/SA |
|
Capacity | Refrigerant | R32 | |
Cooling (Min/Std/Max) | kW | 43/10/12 | |
Heating (Min/Std/Max) | kW | 3.6/11.2/16 | |
Efficiency | Energy grade (Cooling) | EER | 3.7 |
Energy grade (Heating) | COP | 4.1 | |
Energy grade (Cooling) | AEER | 3.69 | |
Energy grade (Heating) | ACOP | 4.09 | |
Electrical | MCA | A | 18.8 |
MFA | A | 18.8 | |
Indoor Unit | Power supply | Ф, #, V, Hz | 3 Phase, 380-415v, 50Hz |
Airflow rate (H, M, L) | l/s | 650/550/450 | |
ESP (L,M,H) | Pa | 29/49/196 | |
Sound pressure @ 1.5m (H/L) | dB(A) | 42/37/32 | |
Supply air opening (WxH) | mm | 1268X270 | |
Return air opening (WxH) | mm | 1268X270 | |
Net weight | kg | 43.5 | |
Unit dimensions (WxHxD) | mm | 1300 x 300 x 700 | |
Drain connection size | mm | OD 32 / ID 25 | |
Drain pump (sold separately) | MDP-G075SP (external type), MDP-G075SQ (internal type) | ||
Outdoor Unit | Power supply | Ф, #, V, Hz | 3 Phase, 380-415v, 50Hz |
Type | Rotary | ||
Sound pressure @ 1m (Cool/Heat) | dB(A) | 51/53 | |
Sound power (Cooling – High) | dB(A) | 68 | |
Net weight | kg | 97.5 | |
Shipping weight | kg | 106.5 | |
Net dimensions (WxHxD) | mm | 940 x 1420 x 330 | |
Shipping dimensions (WxHxD) | mm | 995 x 1598 x 426 | |
Installation | Liquid pipe | 9.52, 3/8” | |
Gas pipe | 15.8, 5/8” | ||
Max. allowable piping length | m | 85 | |
Max. allowable piping height (outdoor above indoor) | m | 30 | |
Pre-charged length | m | 30 | |
Operating Range | Cooling | °C | -15 to 50 |
Heating | °C | -20 to 24 |
Review Samsung S2 10kW AC100TNHDKG/SA, AC100TXAPNG/SA Inverter Ducted system R32, 3 phase