SAMSUNG AC140TNHPKG/SA 14 kW, S2+ Inverter Ducted System 3 Phase

AC140TNHPKG/SA

Price: (Inc GST)

  • Samsung
  • 5 Years
  • In stock

4 Capacity. you are choosing 12-14 kw, 14-16kw

PRODUCT INFORMATION

  • SKU: AC140TNHPKG/SA / AC140TXAPNG/SA / MWR-WE13NB
  • 14.0 kW Cooling
  • 16.5 kW Heating
  • Indoor  AC140TNHPKG/SA 14kW Duct S2+, Split table indoor, R32
  • Outdoor – AC140TXAPKG/SA 13.6/14kW Universal outdoor 3 Phase (Duct S2/S2+, Cassettes) R32
  • Controller – MWR-WE13N Local Controller, wired, NASA

 

KEY FEATURES

  • Powerful Airflow with more fans than ever: The strong and robust construction of our Duct S2+ Indoor Unit brings a maximum of 25% more air volume than our standard model* meaning you stay comfortable in all parts of your home.
  • Energy Superstar – Low Running Cost: The Duct S2+ is a highly energy-efficient system. For an equivalent airflow, it uses less energy*. This leads to a low running cost – meaning you can use your Ducted system all day long without a hefty bill!
  • Easy to Install – Lightweight and Compact: Our Duct S2+ Indoor Units are designed to meet the needs of Australian homes. A lightweight and compact design with a quality finish makes the Duct S2+ easy to maneuver into any space.
  • Innovative Design – Splittable and Tapered: The Duct S2+ splittable type indoor unit can separate the fan and heat exchanger section, making it easier to position into tight roof space – perfect for renovations. The Duct S2+ indoor unit has a tapered fan motor section that fits in between roof trusses. Combined with hanging brackets positioned to minimize obstruction, the installation has never been this easy.
  • Quiet, High Performance – Twin BLDC Compressor and Auto ESP: With a rotary compressor and auto ESP the Duct S2+ heats and cools your spaces in a matter of minutes and maintains optimal air-volume automatically. Able to function in areas with outside air temperatures between −15°C to 50°C for cooling and −20°C to 24°C for heating, enjoy maximum comfort in any Australian environment.
  • Hello R32 Refrigerant! – Low GWP (Global Warming Potential) refrigerant: Low GWP (Global Warming Potential) refrigerant

    Submit your consultation request

    Rules

    • GenuineGenuine Brand new
      100% original, original quality warranty
    • Customer Care
      Customer care
      After-sales, thoughtful support

    Specifications

    Model Name System Indoor unit AC140TNHPKG/SA
    Outdoor unit AC140TXAPNG/SA
    Capacity Cooling (Min/Std/Max) (kW) 5.5 / 14.0 / 17.5
    Heating (Min/Std/Max) (kW) 4.0 / 16.5 / 19.5
    Efficiency
    Energy grade (Cooling) (EER) 3.40
    Energy grade (Heating) (COP) 3.80
    Energy grade (Cooling) (AEER) 3.39
    Energy grade (Heating) (ACOP) 3.80

    Specifications

    Model Name System Indoor unit AC140TNHPKG/SA
    Outdoor unit AC140TXAPNG/SA
    Capacity Cooling (Min/Std/Max) (kW) 5.5 / 14.0 / 17.5
    Heating (Min/Std/Max) (kW) 4.0 / 16.5 / 19.5
    Efficiency
    Energy grade (Cooling) (EER) 3.40
    Energy grade (Heating) (COP) 3.80
    Energy grade (Cooling) (AEER) 3.39
    Energy grade (Heating) (ACOP) 3.80
    Electrical MCA (A) 20.0
    MFA (A) 20.0
    Indoor Unit

    Power supply (Ф, #, V, Hz) 1-phase, 220-240V, 50Hz
    Airflow rate (H, M, L) (l/s) 1,000 / 833 / 650
    ESP (L,M,H) (Pa) 0 / 61 / 150
    Sound pressure @ 1.5m (H/L) (dB(A)) 46 / 41 / 36
    Supply air opening (WxH) (mm) 1154 x 243
    Return air opening (WxH) (mm) 2 x spigot, each spigot to suit Ø16” (Ø400mm) round flexible duct
    Net weight (kg) 66.5
    Unit dimensions (WxHxD)(mm) 1350x360x899
    Drain connection size (mm) OD 32 / ID 25
    Drain pump (sold separately) MDP-G075SP (external type), MDP-G075SQ (internal type)
    Outdoor unit
    Power supply (Ф, #, V, Hz) 3-phase, 380-415V, 50Hz
    Type Rotary
    Sound pressure @ 1m (Cool/Heat) (dB(A)) 54 / 56
    Sound power (Cooling – High) (dB(A)) 70
    Net weight (kg) 100.5
    Net dimensions (WxHxD) (mm) 940 x 1420 x 330
    Installation Liquid pipe (mm, inch) 9.52, 3/8″
    Gas pipe (mm, inch) 15.8, 5/8″
    Max. allowable piping length (m) 85
    Max. allowable piping height (outdoor above indoor)  (m) 30
    Pre-charged length  (m) 30
    Operating range
    Cooling (°C) -15 to 50
    Heating (°C) -20 to 24
    X

    Reviews (0)

    Review SAMSUNG AC140TNHPKG/SA 14 kW, S2+ Inverter Ducted System 3 Phase

    5 0% | 0 reviews
    4 0% | 0 reviews
    3 0% | 0 reviews
    2 0% | 0 reviews
    1 0% | 0 reviews
    Review SAMSUNG AC140TNHPKG/SA 14 kW, S2+ Inverter Ducted System 3 Phase

    Note: For reviews to be approved, please refer to Terms & Conditions

    Specifications

    Model Name System Indoor unit AC140TNHPKG/SA
    Outdoor unit AC140TXAPNG/SA
    Capacity Cooling (Min/Std/Max) (kW) 5.5 / 14.0 / 17.5
    Heating (Min/Std/Max) (kW) 4.0 / 16.5 / 19.5
    Efficiency
    Energy grade (Cooling) (EER) 3.40
    Energy grade (Heating) (COP) 3.80
    Energy grade (Cooling) (AEER) 3.39
    Energy grade (Heating) (ACOP) 3.80

    Specifications

    Model Name System Indoor unit AC140TNHPKG/SA
    Outdoor unit AC140TXAPNG/SA
    Capacity Cooling (Min/Std/Max) (kW) 5.5 / 14.0 / 17.5
    Heating (Min/Std/Max) (kW) 4.0 / 16.5 / 19.5
    Efficiency
    Energy grade (Cooling) (EER) 3.40
    Energy grade (Heating) (COP) 3.80
    Energy grade (Cooling) (AEER) 3.39
    Energy grade (Heating) (ACOP) 3.80
    Electrical MCA (A) 20.0
    MFA (A) 20.0
    Indoor Unit

    Power supply (Ф, #, V, Hz) 1-phase, 220-240V, 50Hz
    Airflow rate (H, M, L) (l/s) 1,000 / 833 / 650
    ESP (L,M,H) (Pa) 0 / 61 / 150
    Sound pressure @ 1.5m (H/L) (dB(A)) 46 / 41 / 36
    Supply air opening (WxH) (mm) 1154 x 243
    Return air opening (WxH) (mm) 2 x spigot, each spigot to suit Ø16” (Ø400mm) round flexible duct
    Net weight (kg) 66.5
    Unit dimensions (WxHxD)(mm) 1350x360x899
    Drain connection size (mm) OD 32 / ID 25
    Drain pump (sold separately) MDP-G075SP (external type), MDP-G075SQ (internal type)
    Outdoor unit
    Power supply (Ф, #, V, Hz) 3-phase, 380-415V, 50Hz
    Type Rotary
    Sound pressure @ 1m (Cool/Heat) (dB(A)) 54 / 56
    Sound power (Cooling – High) (dB(A)) 70
    Net weight (kg) 100.5
    Net dimensions (WxHxD) (mm) 940 x 1420 x 330
    Installation Liquid pipe (mm, inch) 9.52, 3/8″
    Gas pipe (mm, inch) 15.8, 5/8″
    Max. allowable piping length (m) 85
    Max. allowable piping height (outdoor above indoor)  (m) 30
    Pre-charged length  (m) 30
    Operating range
    Cooling (°C) -15 to 50
    Heating (°C) -20 to 24
    0