SAMSUNG AC140TNHPKG/SA 14.0W Ducted S2+ Inverter Ducted Air Conditioner System 1 Phase
AC140TNHPKG/SA/AC140TXAPKG/SA
Price: (Inc GST)
PRODUCT INFORMATION
- SKU: AC140TNHPKG/SA / AC140TXAPKG/SA
- 14.0 kW Cooling
- 16.5 kW Heating
- Indoor: AC140TNHPKG/SA 14kW Duct S2+, Split table indoor, R32
- Outdoor – AC140TXAPKG/SA 13.6/14kW Universal outdoor 1 Phase (Duct S2/S2+, Cassettes) R32
- Controller: MWR-WE13N Local Controller, wired, NASA
KEY FEATURES
- Powerful Airflow with more fans than ever: The strong and robust construction of our Duct S2+ Indoor Unit brings a maximum of 25% more air volume than our standard model* meaning you stay comfortable in all parts of your home.
- Energy Superstar – Low Running Cost: The Duct S2+ is a highly energy-efficient system. For an equivalent airflow, it uses less energy*. This leads to a low running cost – meaning you can use your Ducted system all day long without a hefty bill!
- Easy to Install – Lightweight and Compact: Our Duct S2+ Indoor Units are designed to meet the needs of Australian homes. A lightweight and compact design with a quality finish makes the Duct S2+ easy to maneuver into any space.
- Innovative Design – Splittable and Tapered: The Duct S2+ splittable type indoor unit can separate the fan and heat exchanger section, making it easier to position into tight roof space – perfect for renovations. The Duct S2+ indoor unit has a tapered fan motor section that fits in between roof trusses. Combined with hanging brackets positioned to minimize obstruction, the installation has never been this easy.
- Quiet, High Performance – Twin BLDC Compressor and Auto ESP: With a rotary compressor and auto ESP the Duct S2+ heats and cools your spaces in a matter of minutes and maintains optimal air-volume automatically. Able to function in areas with outside air temperatures between −15°C to 50°C for cooling and −20°C to 24°C for heating, enjoy maximum comfort in any Australian environment.
- Hello R32 Refrigerant! – Low GWP (Global Warming Potential) refrigerant: Low GWP (Global Warming Potential) refrigerant
Specifications
| Model Name System | Indoor unit | AC140TNHPKG/SA |
| Outdoor unit | AC140TXAPKG/SA | |
| Capacity | Cooling (Min/Std/Max) (kW) | 5.5 / 14.0 / 17.5 |
| Heating (Min/Std/Max) (kW) | 4.0 / 16.5 / 19.5 | |
| Efficiency |
Energy grade (Cooling) (EER) | 3.40 |
| Energy grade (Heating) (COP) | 3.80 | |
| Energy grade (Cooling) (AEER) | 3.39 | |
| Energy grade (Heating) (ACOP) | 3.80 |
Specifications
| Model Name System | Indoor unit | AC140TNHPKG/SA |
| Outdoor unit | AC140TXAPKG/SA | |
| Capacity | Cooling (Min/Std/Max) (kW) | 5.5 / 14.0 / 17.5 |
| Heating (Min/Std/Max) (kW) | 4.0 / 16.5 / 19.5 | |
| Efficiency |
Energy grade (Cooling) (EER) | 3.40 |
| Energy grade (Heating) (COP) | 3.80 | |
| Energy grade (Cooling) (AEER) | 3.39 | |
| Energy grade (Heating) (ACOP) | 3.80 | |
| Electrical | MCA (A) | 35.9 |
| MFA (A) | 40.0 | |
| Indoor Unit |
Power supply (Ф, #, V, Hz) | 1-phase, 220-240V, 50Hz |
| Airflow rate (H, M, L) (l/s) | 1,000 / 833 / 650 | |
| ESP (L,M,H) (Pa) | 0 / 61 / 150 | |
| Sound pressure @ 1.5m (H/L) (dB(A)) | 46 / 41 / 36 | |
| Supply air opening (WxH) (mm) | 1154 x 243 | |
| Return air opening (WxH) (mm) | 2 x spigot, each spigot to suit Ø16” (Ø400mm) round flexible duct | |
| Net weight (kg) | 66.5 | |
| Unit dimensions (WxHxD)(mm) | 1350x360x899 | |
| Drain connection size (mm) | OD 32 / ID 25 | |
| Drain pump (sold separately) | MDP-G075SP (external type), MDP-G075SQ (internal type) | |
| Outdoor unit |
Power supply (Ф, #, V, Hz) | 1-phase, 220-240V, 50Hz |
| Type | Rotary | |
| Sound pressure @ 1m (Cool/Heat) (dB(A)) | 54 / 56 | |
| Sound power (Cooling – High) (dB(A)) | 70 | |
| Net weight (kg) | 100.5 | |
| Net dimensions (WxHxD) (mm) | 940 x 1420 x 330 | |
| Installation | Liquid pipe (mm, inch) | 9.52, 3/8″ |
| Gas pipe (mm, inch) | 15.8, 5/8″ | |
| Max. allowable piping length (m) | 85 | |
| Max. allowable piping height (outdoor above indoor) (m) | 30 | |
| Pre-charged length (m) | 30 | |
| Operating range |
Cooling (°C) | -15 to 50 |
| Heating (°C) | -20 to 24 |
X
Reviews (0)
Specifications
| Model Name System | Indoor unit | AC140TNHPKG/SA |
| Outdoor unit | AC140TXAPKG/SA | |
| Capacity | Cooling (Min/Std/Max) (kW) | 5.5 / 14.0 / 17.5 |
| Heating (Min/Std/Max) (kW) | 4.0 / 16.5 / 19.5 | |
| Efficiency |
Energy grade (Cooling) (EER) | 3.40 |
| Energy grade (Heating) (COP) | 3.80 | |
| Energy grade (Cooling) (AEER) | 3.39 | |
| Energy grade (Heating) (ACOP) | 3.80 |
Specifications
| Model Name System | Indoor unit | AC140TNHPKG/SA |
| Outdoor unit | AC140TXAPKG/SA | |
| Capacity | Cooling (Min/Std/Max) (kW) | 5.5 / 14.0 / 17.5 |
| Heating (Min/Std/Max) (kW) | 4.0 / 16.5 / 19.5 | |
| Efficiency |
Energy grade (Cooling) (EER) | 3.40 |
| Energy grade (Heating) (COP) | 3.80 | |
| Energy grade (Cooling) (AEER) | 3.39 | |
| Energy grade (Heating) (ACOP) | 3.80 | |
| Electrical | MCA (A) | 35.9 |
| MFA (A) | 40.0 | |
| Indoor Unit |
Power supply (Ф, #, V, Hz) | 1-phase, 220-240V, 50Hz |
| Airflow rate (H, M, L) (l/s) | 1,000 / 833 / 650 | |
| ESP (L,M,H) (Pa) | 0 / 61 / 150 | |
| Sound pressure @ 1.5m (H/L) (dB(A)) | 46 / 41 / 36 | |
| Supply air opening (WxH) (mm) | 1154 x 243 | |
| Return air opening (WxH) (mm) | 2 x spigot, each spigot to suit Ø16” (Ø400mm) round flexible duct | |
| Net weight (kg) | 66.5 | |
| Unit dimensions (WxHxD)(mm) | 1350x360x899 | |
| Drain connection size (mm) | OD 32 / ID 25 | |
| Drain pump (sold separately) | MDP-G075SP (external type), MDP-G075SQ (internal type) | |
| Outdoor unit |
Power supply (Ф, #, V, Hz) | 1-phase, 220-240V, 50Hz |
| Type | Rotary | |
| Sound pressure @ 1m (Cool/Heat) (dB(A)) | 54 / 56 | |
| Sound power (Cooling – High) (dB(A)) | 70 | |
| Net weight (kg) | 100.5 | |
| Net dimensions (WxHxD) (mm) | 940 x 1420 x 330 | |
| Installation | Liquid pipe (mm, inch) | 9.52, 3/8″ |
| Gas pipe (mm, inch) | 15.8, 5/8″ | |
| Max. allowable piping length (m) | 85 | |
| Max. allowable piping height (outdoor above indoor) (m) | 30 | |
| Pre-charged length (m) | 30 | |
| Operating range |
Cooling (°C) | -15 to 50 |
| Heating (°C) | -20 to 24 |
Related news
Отчего эмоциональные состояния могут изменяться резко
Почему человеку необходимо чувствовать полноту текущего времени
Каким образом предвосхищения выстраивают внутренний психоэмоциональный фон
По какой причине чувства являются частью каждодневных решений
Cronologia delle pratiche di gioco nella penisola italiana dell’epoca medievale


Review SAMSUNG AC140TNHPKG/SA 14.0W Ducted S2+ Inverter Ducted Air Conditioner System 1 Phase