Haier Tempo M-AS35TBMHRA-SET 3.5kW Wall Mounted Reverse Cycle Split System /Built-in Wi-Fi
AS26FBBHRA-SET-1-3
Price: (Inc GST)
PRODUCT INFORMATION
- SKU: AS35TBMHRA/1U35MAMFRA
- 3.5 kW Cooling
- 3.7 kW Heating
Haier Tempo M-AS35TBMHRA/ 1U35MAMFRA Inverter 3.5kW Wall Mounted Reverse Cycle Split System
Wi-Fi & Voice Control
5 Year Warranty
KEY FEATURES
Improved Efficiency
Energy efficient innovations – like the new Eco mode – make this new Tempo design more efficient than our previous Tempo model. Wi-Fi connectivity allows you to control modes, including Eco mode, from your phone.
Intuitive Airflow
Highly engineered airflow to automatically direct warm or cool air for ideal air circulation, air throw of up to 20m, and Turbo Cool for fast cooling relief.
Continuously Clean Air
With a push of a button, your air conditioner initiates Self-Clean, reducing dust and bacteria in the air you breathe, and also improves power consumption efficiency by keeping the heat exchanger clean.
Customised for Australian Conditions and Critters
A wide operating temperature range from -10ºC to 46ºC for cooling and -15ºC to 24ºC for heating, makes this suitable across most of Australia. In the outdoor unit, our Blue Fin coating helps protect against corrosion, and a new gecko-resistant design helps
Stay Connected
Wi-Fi-enabled, this air conditioner allows you to control its functions from anywhere. Enjoy a fast setup and voice control capabilities through Google Home or Amazon Alexa
Specifications
Set | AS35TBMHRA-SET | |
Model | Indoor | AS35TBMHRA |
Outdoor | 1U35MAMFRA | |
Capacity (Min-Max) |
Cooling | 3.5 (1.2-4.0) |
Heating H1 (kW) | 3.7 (1.3-4.2) | |
Heating H2 (kW) | 3.6 | |
Power input (Min-Max) | Cooling (kW) | 0.95 (0.37-1.45) |
Heating (kW) | 1.00 (0.40-1.90) | |
EE / AEER | 3.70 / 3.70 | |
COP / ACOP | 3.70 / 3.68 | |
Star Rating (Hot/Average/Cold) |
Cooling | 3.0 / 3.0 / 3.0 |
Heating | 2.5 / 2.0 / 2.0 | |
TCSPF (Hot/Average/Cold) |
Residential | 4.925/4.615/4.775 |
HSPF Hot/Average/Cold) |
Residential | 4.358/3.949/3.522 |
Specifications
Set | AS35TBMHRA-SET | |
Model | Indoor | AS35TBMHRA |
Outdoor | 1U35MAMFRA | |
Capacity (Min-Max) |
Cooling | 3.5 (1.2-4.0) |
Heating H1 (kW) | 3.7 (1.3-4.2) | |
Heating H2 (kW) | 3.6 | |
Power input (Min-Max) | Cooling (kW) | 0.95 (0.37-1.45) |
Heating (kW) | 1.00 (0.40-1.90) | |
EE / AEER | 3.70 / 3.70 | |
COP / ACOP | 3.70 / 3.68 | |
Star Rating (Hot/Average/Cold) |
Cooling | 3.0 / 3.0 / 3.0 |
Heating | 2.5 / 2.0 / 2.0 | |
TCSPF (Hot/Average/Cold) |
Residential | 4.925/4.615/4.775 |
HSPF Hot/Average/Cold) |
Residential | 4.358/3.949/3.522 |
Electrical | ||
Rated Load Amps (RLA) | Cooling (Amp) | 4.2 |
Heating (Amp) | 4.4 | |
MCA Min circuit (Amp) | 7.0 | |
Suggested Breaker Size (Amp) | 9 | |
Power cable connection location | Outdoor | |
Power supply (Ph/V/Hz) | 1/220-240/50 | |
Refrigeration | ||
Refrigerant Type | R32 | |
Refrigerant Factory Charge (kg) | 0.73 | |
Pipe Size | Liquid Line mm (inch) | 6.35 (¼) |
Suction Line mm (inch) | 9.52 (⅛) | |
Pipe Length (Min-Max) | 3-15 | |
Maximum Height Difference (m) | 10 | |
Precharged up to a Length (m) | 7 | |
Additional Refrigerant (grams/meter) | 20 | |
Indoor unit | ||
External dimensions – W/D/H (mm) | 805x200x292 | |
Net weight (kg) | 9.0 | |
Air Flow T/H/M/L Cooling (L/S) | 208 | |
Sound Pressure Level – SPL (dBA) | 40/36/32/30 | |
Sound Power Level – SWL (dBA) | 57 | |
Remote | YR-HE | |
Outdoor unit | ||
External dimensions – W/D/H (mm) | 800x280x550 | |
Net weight (kg) | 28.0 | |
Compressor Type | Rotary | |
Sound Pressure Level – SPL (dBA) | 52 | |
Sound Power Level – SWL (dBA) | 60 | |
Outdoor Operating Temperature Range | ||
Cooling (Min-Max) | -10°C – 46°C | |
Heating (Min-Max) | -15°C – 24°C |
Reviews (0)
Specifications
Set | AS35TBMHRA-SET | |
Model | Indoor | AS35TBMHRA |
Outdoor | 1U35MAMFRA | |
Capacity (Min-Max) |
Cooling | 3.5 (1.2-4.0) |
Heating H1 (kW) | 3.7 (1.3-4.2) | |
Heating H2 (kW) | 3.6 | |
Power input (Min-Max) | Cooling (kW) | 0.95 (0.37-1.45) |
Heating (kW) | 1.00 (0.40-1.90) | |
EE / AEER | 3.70 / 3.70 | |
COP / ACOP | 3.70 / 3.68 | |
Star Rating (Hot/Average/Cold) |
Cooling | 3.0 / 3.0 / 3.0 |
Heating | 2.5 / 2.0 / 2.0 | |
TCSPF (Hot/Average/Cold) |
Residential | 4.925/4.615/4.775 |
HSPF Hot/Average/Cold) |
Residential | 4.358/3.949/3.522 |
Specifications
Set | AS35TBMHRA-SET | |
Model | Indoor | AS35TBMHRA |
Outdoor | 1U35MAMFRA | |
Capacity (Min-Max) |
Cooling | 3.5 (1.2-4.0) |
Heating H1 (kW) | 3.7 (1.3-4.2) | |
Heating H2 (kW) | 3.6 | |
Power input (Min-Max) | Cooling (kW) | 0.95 (0.37-1.45) |
Heating (kW) | 1.00 (0.40-1.90) | |
EE / AEER | 3.70 / 3.70 | |
COP / ACOP | 3.70 / 3.68 | |
Star Rating (Hot/Average/Cold) |
Cooling | 3.0 / 3.0 / 3.0 |
Heating | 2.5 / 2.0 / 2.0 | |
TCSPF (Hot/Average/Cold) |
Residential | 4.925/4.615/4.775 |
HSPF Hot/Average/Cold) |
Residential | 4.358/3.949/3.522 |
Electrical | ||
Rated Load Amps (RLA) | Cooling (Amp) | 4.2 |
Heating (Amp) | 4.4 | |
MCA Min circuit (Amp) | 7.0 | |
Suggested Breaker Size (Amp) | 9 | |
Power cable connection location | Outdoor | |
Power supply (Ph/V/Hz) | 1/220-240/50 | |
Refrigeration | ||
Refrigerant Type | R32 | |
Refrigerant Factory Charge (kg) | 0.73 | |
Pipe Size | Liquid Line mm (inch) | 6.35 (¼) |
Suction Line mm (inch) | 9.52 (⅛) | |
Pipe Length (Min-Max) | 3-15 | |
Maximum Height Difference (m) | 10 | |
Precharged up to a Length (m) | 7 | |
Additional Refrigerant (grams/meter) | 20 | |
Indoor unit | ||
External dimensions – W/D/H (mm) | 805x200x292 | |
Net weight (kg) | 9.0 | |
Air Flow T/H/M/L Cooling (L/S) | 208 | |
Sound Pressure Level – SPL (dBA) | 40/36/32/30 | |
Sound Power Level – SWL (dBA) | 57 | |
Remote | YR-HE | |
Outdoor unit | ||
External dimensions – W/D/H (mm) | 800x280x550 | |
Net weight (kg) | 28.0 | |
Compressor Type | Rotary | |
Sound Pressure Level – SPL (dBA) | 52 | |
Sound Power Level – SWL (dBA) | 60 | |
Outdoor Operating Temperature Range | ||
Cooling (Min-Max) | -10°C – 46°C | |
Heating (Min-Max) | -15°C – 24°C |