Haier 4U71S2PR1FA 7.1kW Supermatch Multi Head System Reverse Cycle Outdoor Only

4U71S2PR1FA

Price: (Inc GST)

  • Haier
  • 5 Years
  • In stock

5 Capacity. you are choosing 6-8kw

PRODUCT INFORMATION

  • SKU: 4U71S2PR1FA
  • 7.1 kW Cooling
  • 8.0 kW Heating
  • Haier 4U71S2PR1FA 7.1kW Supermatch Multi Head System Reverse Cycle Outdoor Only
  • 4 Port Supermatch 7.1kW Multi RC Outdoor R32

    Submit your consultation request

    Rules

    • GenuineGenuine Brand new
      100% original, original quality warranty
    • Customer Care
      Customer care
      After-sales, thoughtful support

    Specifications

    Model/outdoor unit 4U71S2PR1FA
    Maximum connected quantity of indoor units 4
    Performance data
    Capacity Cooling kW nom 7.1
    (min~max) 2.4~8.7
    Heating kW nom 8.0
    (min~max) 3.1~10
    Rated power input Cooling kW nom 2.0
    (min~max) 0.55~3.4
    Heating kW nom 2.0
    (min~max) 0.55~3.1
    EER/COP 3.64/4.10
    AEER/ACOP 3.52/3.97

    Specifications

    Model/outdoor unit 4U71S2PR1FA
    Maximum connected quantity of indoor units 4
    Performance data
    Capacity Cooling kW nom 7.1
    (min~max) 2.4~8.7
    Heating kW nom 8.0
    (min~max) 3.1~10
    Rated power input Cooling kW nom 2.0
    (min~max) 0.55~3.4
    Heating kW nom 2.0
    (min~max) 0.55~3.1
    EER/COP 3.64/4.10
    AEER/ACOP 3.52/3.97
    Electrical Parameters
    Power supply Ph/V/Hz 1/220~240/50/60
    Rated Load Amps (RLA) Cooling Amp 8.7/8.7
    Maximum Amps Heating Amp 14.7/13.5
    Breaker Size Amp 25
    Performance
    Air flow (H/M/L) m3/h 4000
    Sound power level (H/M/L) dB(A) 68
    Sound pressure level (H/M/L) dB(A) 55
    Installation
    External dimensions (W/D/H) mm 890x340x700
    Shipping dimensions (W/D/H) mm 1010x455x835
    Net/Shipping weight kg 61/70
    Compressor type Twin Rotary (DC Inverter)
    Refrigerant type / Charge R32 / 2.2
    GWP 675
    Refrigerant liquid pipe mm 4xØ6.35
    Refrigerant gas pipe mm 3xØ9.52 + 1xØ12.7
    Total pipe length (Max) m 70
    Single pipe length (Max) m 25
    Max height between I.U. & O.U m 15
    Max height between I.U.& I.U m 7.5
    Pre–charge length m 40
    Additional refrigerant charge g/m 20
    Working temp
    Cooling(Min–Max) ºC –10 to +46
    Heating(Min–Max) ºC –15 to +24
    X

    Reviews (0)

    Review Haier 4U71S2PR1FA 7.1kW Supermatch Multi Head System Reverse Cycle Outdoor Only

    5 0% | 0 reviews
    4 0% | 0 reviews
    3 0% | 0 reviews
    2 0% | 0 reviews
    1 0% | 0 reviews
    Review Haier 4U71S2PR1FA 7.1kW Supermatch Multi Head System Reverse Cycle Outdoor Only

    Note: For reviews to be approved, please refer to Terms & Conditions

    Specifications

    Model/outdoor unit 4U71S2PR1FA
    Maximum connected quantity of indoor units 4
    Performance data
    Capacity Cooling kW nom 7.1
    (min~max) 2.4~8.7
    Heating kW nom 8.0
    (min~max) 3.1~10
    Rated power input Cooling kW nom 2.0
    (min~max) 0.55~3.4
    Heating kW nom 2.0
    (min~max) 0.55~3.1
    EER/COP 3.64/4.10
    AEER/ACOP 3.52/3.97

    Specifications

    Model/outdoor unit 4U71S2PR1FA
    Maximum connected quantity of indoor units 4
    Performance data
    Capacity Cooling kW nom 7.1
    (min~max) 2.4~8.7
    Heating kW nom 8.0
    (min~max) 3.1~10
    Rated power input Cooling kW nom 2.0
    (min~max) 0.55~3.4
    Heating kW nom 2.0
    (min~max) 0.55~3.1
    EER/COP 3.64/4.10
    AEER/ACOP 3.52/3.97
    Electrical Parameters
    Power supply Ph/V/Hz 1/220~240/50/60
    Rated Load Amps (RLA) Cooling Amp 8.7/8.7
    Maximum Amps Heating Amp 14.7/13.5
    Breaker Size Amp 25
    Performance
    Air flow (H/M/L) m3/h 4000
    Sound power level (H/M/L) dB(A) 68
    Sound pressure level (H/M/L) dB(A) 55
    Installation
    External dimensions (W/D/H) mm 890x340x700
    Shipping dimensions (W/D/H) mm 1010x455x835
    Net/Shipping weight kg 61/70
    Compressor type Twin Rotary (DC Inverter)
    Refrigerant type / Charge R32 / 2.2
    GWP 675
    Refrigerant liquid pipe mm 4xØ6.35
    Refrigerant gas pipe mm 3xØ9.52 + 1xØ12.7
    Total pipe length (Max) m 70
    Single pipe length (Max) m 25
    Max height between I.U. & O.U m 15
    Max height between I.U.& I.U m 7.5
    Pre–charge length m 40
    Additional refrigerant charge g/m 20
    Working temp
    Cooling(Min–Max) ºC –10 to +46
    Heating(Min–Max) ºC –15 to +24
    0