DAIKIN FDYQN200LC-MY 19.5kW Inverter Ducted Air Conditioner System 3 Phase
FDYQN200LC-MY
Price: (Inc GST)
PRODUCT INFORMATION
- Ducted Inverter three phase
- SKU: FDYQN200LC-MY / BRC1E63
- 19.5 kW Cooling
- 22.4 kW Heating
- Daikin FDYQN200LC-MY Reverse Cycle Inverter Ducted Aircon System 3 Phase
- Includes Indoor – FDYQN200LCV1 | Outdoor – RZQ200MY1
- Available Controllers:
- Included: BRC1E63 – Standard controller
KEY FEATURES
It’s the unique features of Daikin products that makes us the world leader.
Improved Energy Efficiency: Achieved through the use of a DC Fan motor, cross-pass heat exchanger and increased outdoor coil passes.
Compact Indoor Unit: Low profile height of ≤360mm to fit comfortably into the tight roof space of a modern home.
Space Saving Outdoor Unit: Models up to 19.5kW are encased in a space saving side discharge outdoor unit allowing for flexible placement.
Night Quiet Mode: Reduces the outdoor noise levels during sleeping hours and automatically resumes normal operations in the morning.
R22 Retrofit Capability: Provides a cost effective and convenient upgrade from an existing R22 ducted system whilst retaining the field piping (5.0-15.5kW Models).
Australian Made: Indoor units are specifically designed and manufactured to Australian standards to withstand the harsher summer climate.
Specifications
Indoor Unit | FDYQN200LCV1 | |
Outdoor Unit | RZQ200MY1 | |
Rated Capacity | Cool (kW) | 19.5 |
Heat (kW) | 22.4 | |
Capacity Range | Cool (kW) | 10.1-19.5 |
Heat (kW) | 11.2-22.4 | |
Power Input (Rated) | Cool (kW) | 6.11 |
Heat (kW) | 6.85 | |
E.E.R/C.O.P | C/H | 3.19/3.27 |
Specifications
Indoor Unit | FDYQN200LCV1 | |
Outdoor Unit | RZQ200MY1 | |
Rated Capacity | Cool (kW) | 19.5 |
Heat (kW) | 22.4 | |
Capacity Range | Cool (kW) | 10.1-19.5 |
Heat (kW) | 11.2-22.4 | |
Power Input (Rated) | Cool (kW) | 6.11 |
Heat (kW) | 6.85 | |
E.E.R/C.O.P | C/H | 3.19/3.27 |
TCSPF (Residential) | Hot/Average/Cold | 3.57/3.14/3.11 |
HSPF (Residential) | Hot/Average/Cold | 3.25/2.97/2.63 |
Airflow Rate (Nominal/Max) | l/s | 1400/1600 |
Indoor Sound Level (H) @1.5m | dBA (C/H) | 46.0/46.0 |
Piping Length | m | 50 |
Indoor Fan Speeds | H/M/L | |
Dimensions (HxWxD) | Indoor (mm) | 470x1400x997 |
Outdoor (mm) | 1430x940x320 | |
Weight | Indoor (kg) | 85 |
Outdoor (kg) | 138 | |
Power Supply | V/Hz | 3 Phase, 380-415V, 50Hz |
Compressor Type | Hermetically Sealed Scroll Type | |
Refrigerant | R410A | |
Pipe Sizes | Liquid (mm) | 9.5 (Brazed) |
Gas (mm) | 19.1 (Brazed) | |
Drain (mm) | BSP 3/4 inch Internal Thread | |
Supply Air Opening | mm (HxW, Flange) | 350×1118 |
Return Air Opening | mm | 393×1118 (Flange) |
Outdoor Operating Range | Cool (ºCDB) | -5 to 43 |
Heat (ºCWB) | -20 to 16 | |
EPA Sound Power Level | dBA | 74 |
Outdoor Sound Level (H) @1m | Pressure dBA (C/H) | 58/59 |
Reviews (0)
Specifications
Indoor Unit | FDYQN200LCV1 | |
Outdoor Unit | RZQ200MY1 | |
Rated Capacity | Cool (kW) | 19.5 |
Heat (kW) | 22.4 | |
Capacity Range | Cool (kW) | 10.1-19.5 |
Heat (kW) | 11.2-22.4 | |
Power Input (Rated) | Cool (kW) | 6.11 |
Heat (kW) | 6.85 | |
E.E.R/C.O.P | C/H | 3.19/3.27 |
Specifications
Indoor Unit | FDYQN200LCV1 | |
Outdoor Unit | RZQ200MY1 | |
Rated Capacity | Cool (kW) | 19.5 |
Heat (kW) | 22.4 | |
Capacity Range | Cool (kW) | 10.1-19.5 |
Heat (kW) | 11.2-22.4 | |
Power Input (Rated) | Cool (kW) | 6.11 |
Heat (kW) | 6.85 | |
E.E.R/C.O.P | C/H | 3.19/3.27 |
TCSPF (Residential) | Hot/Average/Cold | 3.57/3.14/3.11 |
HSPF (Residential) | Hot/Average/Cold | 3.25/2.97/2.63 |
Airflow Rate (Nominal/Max) | l/s | 1400/1600 |
Indoor Sound Level (H) @1.5m | dBA (C/H) | 46.0/46.0 |
Piping Length | m | 50 |
Indoor Fan Speeds | H/M/L | |
Dimensions (HxWxD) | Indoor (mm) | 470x1400x997 |
Outdoor (mm) | 1430x940x320 | |
Weight | Indoor (kg) | 85 |
Outdoor (kg) | 138 | |
Power Supply | V/Hz | 3 Phase, 380-415V, 50Hz |
Compressor Type | Hermetically Sealed Scroll Type | |
Refrigerant | R410A | |
Pipe Sizes | Liquid (mm) | 9.5 (Brazed) |
Gas (mm) | 19.1 (Brazed) | |
Drain (mm) | BSP 3/4 inch Internal Thread | |
Supply Air Opening | mm (HxW, Flange) | 350×1118 |
Return Air Opening | mm | 393×1118 (Flange) |
Outdoor Operating Range | Cool (ºCDB) | -5 to 43 |
Heat (ºCWB) | -20 to 16 | |
EPA Sound Power Level | dBA | 74 |
Outdoor Sound Level (H) @1m | Pressure dBA (C/H) | 58/59 |
Review DAIKIN FDYQN200LC-MY 19.5kW Inverter Ducted Air Conditioner System 3 Phase