DAIKIN FDYQ250LC-TY 24.0kW Premium Inverter Ducted AC System | 3 Phase
FDYQ250LC-TY
Price: (Inc GST)
PRODUCT INFORMATION
- Ducted Premium Inverter Three phase
- SKU: FDYQ250LC-TY / BRC1E63
- 24.0kW Cooling Capacity
- 26.8kW Heating Capacity
- DAIKIN FDYQ250LC-TY 24kW Premium Inverter Ducted System | 3 Phase
- Indoor FDYQ250LCV1
- Outdoor RZYQ10TY1
- Available Controllers:BRC1E63 – Standard
KEY FEATURES
It’s the unique features of Daikin products that makes us the world leader.
Industry Leading Energy Performance: Achieved with a redesigned cross-pass heat exchanger, DC fan motor and improved refrigerant control technology.
Night Quiet Mode: Reduces the outdoor noise levels during sleeping hours and automatically resumes normal operations in the morning.
Increased Operation Limits: The refrigerant cooled PCB technology incorporated in the outdoor unit enables continuous operations up to 50°CDB ambient.
Heating Focus Option: Heating Focus models are available from 18.0-24.0kW with improved heating performance, ideal for cold climates such as Canberra, Hobart & Melbourne.
R22 Retrofit Capability: Provides a cost effective and convenient upgrade from an existing R22 ducted system whilst retaining the field piping (not available for Heating Focus models).
Australian Made: Indoor units are specifically designed and manufactured to Australian standards to withstand the harsher summer climate.
Specifications
| INDOOR UNIT | FDYQ200LCV1 | |
| OUTDOOR UNIT | RZYQ8TY1 | |
| Rated Capacity | Cool (kW) | 20.0 |
| Heat (kW) | 22.4 | |
| Capacity Range | Cool (kW) | 10.0-22.4 |
| Heat (kW) | 11.2-25.0 | |
| Power Input (Rated) | Cool (kW) | 6.08 |
| Heat (kW) | 6.17 | |
| E.E.R/C.O.P | C/H | 3.29/3.63 |
Specifications
| INDOOR UNIT | FDYQ250LCV1 | |
| OUTDOOR UNIT | RZYQ10TY1 | |
| Rated Capacity | Cool (kW) | 24.0 |
| Heat (kW) | 26.8 | |
| Capacity Range | Cool (kW) | 11.7-24.0 |
| Heat (kW) | 13.4-26.8 | |
| Power Input (Rated) | Cool (kW) | 7.47 |
| Heat (kW) | 8.14 | |
| E.E.R/C.O.P | C/H | 3.21/3.29 |
| TCSPF (Residential) | Hot/Average/Cold | – |
| HSPF (Residential) | Hot/Average/Cold | – |
| Airflow Rate (Nominal/Max) | l/s | 1400/1600 |
| Indoor Sound Level (H) @1.5m | dBA (C/H) | 46.0/46.0 |
| Piping Length | m | 150 |
| Indoor Fan Speeds | H/M/L | |
| Dimensions (HxWxD) | Indoor (mm) | 470x1400x997 |
| Outdoor (mm) | 1657x930x765 | |
| Weight | Indoor (kg) | 85 |
| Outdoor (kg) | 203 | |
| Power Supply | V/Hz | 3 Phase, 380-415V, 50Hz |
| Compressor Type | Hermetically Sealed Scroll Type | |
| Refrigerant | R410A | |
| Pipe Sizes | Liquid (mm) | 9.5 (Brazed) |
| Gas (mm) | 22.2 (Brazed) | |
| Drain (mm) | BSP 3/4 inch Internal Thread | |
| Supply Air Opening | mm (HxW, Flange) | 350×1118 |
| Return Air Opening | mm | 393×1118 (Flange) |
| Outdoor Operating Range | Cool (ºCDB) | -5 to 49 |
| Heat (ºCWB) | -20 to 16 | |
| EPA Sound Power Level | dBA | – |
| Outdoor Sound Level (H) @1m | Pressure dBA (C/H) | 57/57 |
Reviews (0)
Specifications
| INDOOR UNIT | FDYQ200LCV1 | |
| OUTDOOR UNIT | RZYQ8TY1 | |
| Rated Capacity | Cool (kW) | 20.0 |
| Heat (kW) | 22.4 | |
| Capacity Range | Cool (kW) | 10.0-22.4 |
| Heat (kW) | 11.2-25.0 | |
| Power Input (Rated) | Cool (kW) | 6.08 |
| Heat (kW) | 6.17 | |
| E.E.R/C.O.P | C/H | 3.29/3.63 |
Specifications
| INDOOR UNIT | FDYQ250LCV1 | |
| OUTDOOR UNIT | RZYQ10TY1 | |
| Rated Capacity | Cool (kW) | 24.0 |
| Heat (kW) | 26.8 | |
| Capacity Range | Cool (kW) | 11.7-24.0 |
| Heat (kW) | 13.4-26.8 | |
| Power Input (Rated) | Cool (kW) | 7.47 |
| Heat (kW) | 8.14 | |
| E.E.R/C.O.P | C/H | 3.21/3.29 |
| TCSPF (Residential) | Hot/Average/Cold | – |
| HSPF (Residential) | Hot/Average/Cold | – |
| Airflow Rate (Nominal/Max) | l/s | 1400/1600 |
| Indoor Sound Level (H) @1.5m | dBA (C/H) | 46.0/46.0 |
| Piping Length | m | 150 |
| Indoor Fan Speeds | H/M/L | |
| Dimensions (HxWxD) | Indoor (mm) | 470x1400x997 |
| Outdoor (mm) | 1657x930x765 | |
| Weight | Indoor (kg) | 85 |
| Outdoor (kg) | 203 | |
| Power Supply | V/Hz | 3 Phase, 380-415V, 50Hz |
| Compressor Type | Hermetically Sealed Scroll Type | |
| Refrigerant | R410A | |
| Pipe Sizes | Liquid (mm) | 9.5 (Brazed) |
| Gas (mm) | 22.2 (Brazed) | |
| Drain (mm) | BSP 3/4 inch Internal Thread | |
| Supply Air Opening | mm (HxW, Flange) | 350×1118 |
| Return Air Opening | mm | 393×1118 (Flange) |
| Outdoor Operating Range | Cool (ºCDB) | -5 to 49 |
| Heat (ºCWB) | -20 to 16 | |
| EPA Sound Power Level | dBA | – |
| Outdoor Sound Level (H) @1m | Pressure dBA (C/H) | 57/57 |
Related news
The overall game uses four reels and you will 10 paylines, that’s an extremely familiar Novomatic structure
Sweepstakes gambling enterprises, labeled as personal gambling enterprises try try legal during the 44 states, except Washington state
Particular casinos on the internet need you to find the desired extra during the registration
To be certain fair enjoy, simply prefer harbors out of acknowledged web based casinos
Top Sweepstakes Gambling enterprises in the us: Confirmed Sweeps Casinos


Review DAIKIN FDYQ250LC-TY 24.0kW Premium Inverter Ducted AC System | 3 Phase