DAIKIN FDYQ180LC-TA2Y 18kW Premium Inverter Heating Focus | 3 Phase
FDYQ180LC-TA2Y
Price: (Inc GST)
PRODUCT INFORMATION
- Ducted Premium Inverter Three phase
- SKU: FDYQ180LC-TA2Y / BRC1E63
- 18.0 kW Cooling
- 20.0 kW Heating
- DAIKIN FDYQ180LC-TA2Y (Previously known: FDYQ180LC-TAY) 18kW Premium Inverter Heating Focus | 3 Phase/R410A
- Indoor: FDYQ180LCV1
- Outdoor: RZYQ7TA2Y1 (Previously known: RZYQ7TAY1)
- Available Controllers:BRC1E63 – Standard
KEY FEATURES
It’s the unique features of Daikin products that makes us the world leader.
Industry Leading Energy Performance: Achieved with a redesigned cross-pass heat exchanger, DC fan motor and improved refrigerant control technology.
Night Quiet Mode: Reduces the outdoor noise levels during sleeping hours and automatically resumes normal operations in the morning.
Increased Operation Limits: The refrigerant cooled PCB technology incorporated in the outdoor unit enables continuous operations up to 50°CDB ambient.
Heating Focus Option: Heating Focus models are available from 18.0-24.0kW with improved heating performance, ideal for cold climates such as Canberra, Hobart & Melbourne.
R22 Retrofit Capability: Provides a cost effective and convenient upgrade from an existing R22 ducted system whilst retaining the field piping (not available for Heating Focus models).
Australian Made: Indoor units are specifically designed and manufactured to Australian standards to withstand the harsher summer climate.
Specifications
| INDOOR UNIT | FDYQ180LCV1 | |
| OUTDOOR UNIT | RZYQ7TAY1 | |
| Rated Capacity | Cool (kW) | 18.0 |
| Heat (kW) | 20.0 | |
| Capacity Range | Cool (kW) | 9.0-20.0 |
| Heat (kW) | 10.0-22.4 | |
| Power Input (Rated) | Cool (kW) | 5.61 |
| Heat (kW) | 5.81 | |
| E.E.R/C.O.P | C/H | 3.21/3.44 |
Specifications
| INDOOR UNIT | FDYQ180LCV1 | |
| OUTDOOR UNIT | RZYQ7TAY1 | |
| Rated Capacity | Cool (kW) | 18.0 |
| Heat (kW) | 20.0 | |
| Capacity Range | Cool (kW) | 9.0-20.0 |
| Heat (kW) | 10.0-22.4 | |
| Power Input (Rated) | Cool (kW) | 5.61 |
| Heat (kW) | 5.81 | |
| E.E.R/C.O.P | C/H | 3.21/3.44 |
| TCSPF (Residential) | Hot/Average/Cold | 3.79/3.23/3.19 |
| HSPF (Residential) | Hot/Average/Cold | 3.21/3.15/3.02 |
| Airflow Rate (Nominal/Max) | l/s | 1160/1200 |
| Indoor Sound Level (H) @1.5m | dBA (C/H) | 45.0/45.0 |
| Piping Length | m | 165 |
| Indoor Fan Speeds | H/M/L | |
| Dimensions (HxWxD) | Indoor (mm) | 470x1200x997 |
| Outdoor (mm) | 1657x930x765 | |
| Weight | Indoor (kg) | 70 |
| Outdoor (kg) | 185 | |
| Power Supply | V/Hz | 3 Phase, 380-415V, 50Hz |
| Compressor Type | Hermetically Sealed Scroll Type | |
| Refrigerant | R410A | |
| Pipe Sizes | Liquid (mm) | 9.5 (Brazed) |
| Gas (mm) | 19.1 (Brazed) | |
| Drain (mm) | BSP 3/4 inch Internal Thread | |
| Supply Air Opening | mm (HxW, Flange) | 350×918 |
| Return Air Opening | mm | 393×918 (Flange) |
| Outdoor Operating Range | Cool (ºCDB) | -5 to 49 |
| Heat (ºCWB) | -20 to 16 | |
| EPA Sound Power Level | dBA | 76 |
| Outdoor Sound Level (H) @1m | Pressure dBA (C/H) | 56/56 |
Reviews (0)
Specifications
| INDOOR UNIT | FDYQ180LCV1 | |
| OUTDOOR UNIT | RZYQ7TAY1 | |
| Rated Capacity | Cool (kW) | 18.0 |
| Heat (kW) | 20.0 | |
| Capacity Range | Cool (kW) | 9.0-20.0 |
| Heat (kW) | 10.0-22.4 | |
| Power Input (Rated) | Cool (kW) | 5.61 |
| Heat (kW) | 5.81 | |
| E.E.R/C.O.P | C/H | 3.21/3.44 |
Specifications
| INDOOR UNIT | FDYQ180LCV1 | |
| OUTDOOR UNIT | RZYQ7TAY1 | |
| Rated Capacity | Cool (kW) | 18.0 |
| Heat (kW) | 20.0 | |
| Capacity Range | Cool (kW) | 9.0-20.0 |
| Heat (kW) | 10.0-22.4 | |
| Power Input (Rated) | Cool (kW) | 5.61 |
| Heat (kW) | 5.81 | |
| E.E.R/C.O.P | C/H | 3.21/3.44 |
| TCSPF (Residential) | Hot/Average/Cold | 3.79/3.23/3.19 |
| HSPF (Residential) | Hot/Average/Cold | 3.21/3.15/3.02 |
| Airflow Rate (Nominal/Max) | l/s | 1160/1200 |
| Indoor Sound Level (H) @1.5m | dBA (C/H) | 45.0/45.0 |
| Piping Length | m | 165 |
| Indoor Fan Speeds | H/M/L | |
| Dimensions (HxWxD) | Indoor (mm) | 470x1200x997 |
| Outdoor (mm) | 1657x930x765 | |
| Weight | Indoor (kg) | 70 |
| Outdoor (kg) | 185 | |
| Power Supply | V/Hz | 3 Phase, 380-415V, 50Hz |
| Compressor Type | Hermetically Sealed Scroll Type | |
| Refrigerant | R410A | |
| Pipe Sizes | Liquid (mm) | 9.5 (Brazed) |
| Gas (mm) | 19.1 (Brazed) | |
| Drain (mm) | BSP 3/4 inch Internal Thread | |
| Supply Air Opening | mm (HxW, Flange) | 350×918 |
| Return Air Opening | mm | 393×918 (Flange) |
| Outdoor Operating Range | Cool (ºCDB) | -5 to 49 |
| Heat (ºCWB) | -20 to 16 | |
| EPA Sound Power Level | dBA | 76 |
| Outdoor Sound Level (H) @1m | Pressure dBA (C/H) | 56/56 |
Related news
Отчего эмоциональные состояния могут изменяться резко
Почему человеку необходимо чувствовать полноту текущего времени
Каким образом предвосхищения выстраивают внутренний психоэмоциональный фон
По какой причине чувства являются частью каждодневных решений
Cronologia delle pratiche di gioco nella penisola italiana dell’epoca medievale


Review DAIKIN FDYQ180LC-TA2Y 18kW Premium Inverter Heating Focus | 3 Phase