DAIKIN FDYAN100A-C2Y 10.0kW Inverter Ducted Air Conditioner System 3 Phase
FDYAN100A-C2Y
Price: (Inc GST)
PRODUCT INFORMATION
- Ducted Inverter three phase
- SKU: FDYAN100A-C2Y / BRC1E63
- 10.0 kW Cooling
- 12.5 kW Heating
- DAIKIN FDYAN100A-C2Y 10kW Inverter Ducted System 3 Phase
- Includes Indoor: FDYAN100AV1
- Outdoor: RZA100C2Y1
- Included: BRC1E63 – Standard controller
KEY FEATURES
It’s the unique features of Daikin products that makes us the world leader.
Improved Energy Efficiency: Achieved through the use of a DC Fan motor, cross-pass heat exchanger and increased outdoor coil passes.
Compact Indoor Unit: Low profile height of ≤360mm to fit comfortably into the tight roof space of a modern home.
Space Saving Outdoor Unit: Models up to 19.5kW are encased in a space saving side discharge outdoor unit allowing for flexible placement.
Night Quiet Mode: Reduces the outdoor noise levels during sleeping hours and automatically resumes normal operations in the morning.
R22 Retrofit Capability: Provides a cost effective and convenient upgrade from an existing R22 ducted system whilst retaining the field piping (5.0-15.5kW Models).
Australian Made: Indoor units are specifically designed and manufactured to Australian standards to withstand the harsher summer climate.
Specifications
| Indoor Unit | FDYAN100AV | |
| Outdoor Unit | RZA100C2Y1 | |
| Rated Capacity | Cool (kW) | 10.0 |
| Heat (kW) | 12.5 | |
| Capacity Range | Cool (kW) | 3.2-11.2 |
| Heat (kW) | 3.5-14.0 | |
| Power Input (Rated) | Cool (kW) | 3.10 |
| Heat (kW) | 3.35 | |
| E.E.R/C.O.P | C/H | 3.23/3.73 |
Specifications
| Indoor Unit | FDYAN100AV | |
| Outdoor Unit | RZA100C2Y1 | |
| Rated Capacity | Cool (kW) | 10.0 |
| Heat (kW) | 12.5 | |
| Capacity Range | Cool (kW) | 3.2-11.2 |
| Heat (kW) | 3.5-14.0 | |
| Power Input (Rated) | Cool (kW) | 3.10 |
| Heat (kW) | 3.35 | |
| E.E.R/C.O.P | C/H | 3.23/3.73 |
| TCSPF (Residential) | Hot/Average/Cold | 4.28/3.88/3.97 |
| HSPF (Residential) | Hot/Average/Cold | 3.85/3.48/3.04 |
| Airflow Rate (Nominal/Max) | l/s | 680/800 |
| Indoor Sound Level (H) @1.5m | dBA (C/H) | 43.5/45.8 |
| Piping Length | m | 50 |
| Indoor Fan Speeds | H/M/L | |
| Dimensions (HxWxD) | Indoor (mm) | 300x1210x900 |
| Outdoor (mm) | 990x940x320 | |
| Weight | Indoor (kg) | 45 |
| Outdoor (kg) | 69 | |
| Power Supply | V/Hz | 3 Phase, 380-415V, 50Hz |
| Compressor Type | Hermetically Sealed Swing Type | |
| Refrigerant | R32 | |
| Pipe Sizes | Liquid (mm) | 9.5 (Flare) |
| Gas (mm) | 15.9 (Flare) | |
| Drain (mm) | ID 25 / OD 32 | |
| Supply Air Opening | mm (HxW, Flange) | 185×852 |
| Return Air Opening | mm | 2×350 (Oval) |
| Outdoor Operating Range | Cool (ºCDB) | -5 to 46 |
| Heat (ºCWB) | -15 to 16 | |
| EPA Sound Power Level | dBA | 71 |
| Outdoor Sound Level (H) @1m | Pressure dBA (C/H) | 52/54 |
Reviews (0)
Specifications
| Indoor Unit | FDYAN100AV | |
| Outdoor Unit | RZA100C2Y1 | |
| Rated Capacity | Cool (kW) | 10.0 |
| Heat (kW) | 12.5 | |
| Capacity Range | Cool (kW) | 3.2-11.2 |
| Heat (kW) | 3.5-14.0 | |
| Power Input (Rated) | Cool (kW) | 3.10 |
| Heat (kW) | 3.35 | |
| E.E.R/C.O.P | C/H | 3.23/3.73 |
Specifications
| Indoor Unit | FDYAN100AV | |
| Outdoor Unit | RZA100C2Y1 | |
| Rated Capacity | Cool (kW) | 10.0 |
| Heat (kW) | 12.5 | |
| Capacity Range | Cool (kW) | 3.2-11.2 |
| Heat (kW) | 3.5-14.0 | |
| Power Input (Rated) | Cool (kW) | 3.10 |
| Heat (kW) | 3.35 | |
| E.E.R/C.O.P | C/H | 3.23/3.73 |
| TCSPF (Residential) | Hot/Average/Cold | 4.28/3.88/3.97 |
| HSPF (Residential) | Hot/Average/Cold | 3.85/3.48/3.04 |
| Airflow Rate (Nominal/Max) | l/s | 680/800 |
| Indoor Sound Level (H) @1.5m | dBA (C/H) | 43.5/45.8 |
| Piping Length | m | 50 |
| Indoor Fan Speeds | H/M/L | |
| Dimensions (HxWxD) | Indoor (mm) | 300x1210x900 |
| Outdoor (mm) | 990x940x320 | |
| Weight | Indoor (kg) | 45 |
| Outdoor (kg) | 69 | |
| Power Supply | V/Hz | 3 Phase, 380-415V, 50Hz |
| Compressor Type | Hermetically Sealed Swing Type | |
| Refrigerant | R32 | |
| Pipe Sizes | Liquid (mm) | 9.5 (Flare) |
| Gas (mm) | 15.9 (Flare) | |
| Drain (mm) | ID 25 / OD 32 | |
| Supply Air Opening | mm (HxW, Flange) | 185×852 |
| Return Air Opening | mm | 2×350 (Oval) |
| Outdoor Operating Range | Cool (ºCDB) | -5 to 46 |
| Heat (ºCWB) | -15 to 16 | |
| EPA Sound Power Level | dBA | 71 |
| Outdoor Sound Level (H) @1m | Pressure dBA (C/H) | 52/54 |
Related news
Consider the necessary public gambling enterprises to have a much better experience
The fresh mobile web site adjusts instantly to your mobile phone otherwise tablet display when reached compliment of internet browsers for example Chrome, Safari, or Firefox