Actronair MultiElite Series 2- MRC-120CS-5 11.85 kW Outdoor Unit Only One phase R32 - 5 Heads
MRC-120CS-5
Price: (Inc GST)
- SKU: MRC-120CS-5
- Cooling: 11.85 kW
- Heating: 12.5 kW
- Actronair MultiElite Series 2- MRC-120CS-5 11.85.0 kW Outdoor Unit Only One phase R32 – 5 Heads
- Wired Wall Controller – WC-02 Included
- Built In Drain Pump Included
Key Features
Capacity to suit your needs
Coated Coil Protection
Different temperatures in different rooms
Easy installation and commissioning
Specifications
OUTDOOR MODEL | MRC-120CS-5 | |
Nett (Rated) Capacity (kW) (AS/NZS3823.1.4) | Cooling (min-max) | 11.85 |
Heating (min-max) | 12.50 | |
Input Power (kW) (AS/NZS3823.1.4) | Cooling Rated | 3.15 |
Heating Rated | 3.25 | |
1 EER Rated (AS/NZS3823.1.4) 2 COP Rated (AS/NZS3823.1.4) |
Cooling Rated | 3.76 |
Heating Rated | 3.85 |
Specifications
OUTDOOR MODEL | MRC-120CS-5 | |
APPLICABLE INDOOR MODEL/S | Wall Hung | WRE-026CS |
WRE-035CS | ||
WRE-050CS | ||
WRE-072CS | ||
WRE-085CS | ||
Bulkhead | BRE-026CS | |
BRE-035CS | ||
BRE-050CS | ||
BRE-070CS | ||
Mini-Cassette | MRE-035CS | |
MRE-050CS | ||
Nett (Rated) Capacity (kW) (AS/NZS3823.1.4) | Cooling (min-max) | 11.85 |
Heating (min-max) | 12.50 | |
Input Power (kW) (AS/NZS3823.1.4) | Cooling Rated | 3.15 |
Heating Rated | 3.25 | |
1 EER Rated (AS/NZS3823.1.4) 2 COP Rated (AS/NZS3823.1.4) |
Cooling Rated | 3.76 |
Heating Rated | 3.85 | |
Power Supply – (V / Ph / Hz) | Outdoor | 220 – 240 V / 1Ph+N / 50Hz |
Rated Load Amps (AS/NZS3823.1.4) | Cooling | 14.7 |
Heating | 15.8 | |
Full Load Amps | 3 Maximum possible combination | 26.4 |
Outdoor Unit Only | 19.0 | |
4 Circuit Breaker Amps and Main Cable Amps | 32.0 | |
5 Suggested Minimum Indoor to Outdoor Cable Size & Type | ||
IP Rating | Outdoor | IPX4 |
Compressor Type | Inverter Twin-Rotary | |
Refrigerant | R32 | |
Outdoor Dimensions (mm) | Depth | 410 |
Height | 810 | |
Width | 946 | |
6 Nominal Weight (kgs) | Outdoor | 75.9 |
7 Outdoor Sound Pressure Level (dBA) 1m | 62.6 | |
8 Outdoor Sound Power Level (dBA) | 73 | |
Outdoor Operating Range (°C) | Cooling | -15°C to 50°C |
Heating | -25°C to 30°C | |
MEPS Compliant | YES | |
Technical Information | ||
Refrigerant Charge | Factory Charge – (g) | 2950 |
Pre-Charge Length – (m) | 5 x 10m | |
Additional Refrigerant Charge – (g/m) | 12 | |
Minimum Field Pipe Length – (m) | 1 indoor unit | 12 |
Maximum Field Pipe Length – (m) | For all rooms | 80 |
For 1 indoor unit | 35 | |
Maximum Vertical Height Differential (m) included in max length | From OD unit to ID unit | 15 |
From ID unit to ID unit | 15 | |
Outdoor Unit Connections | Liquid Pipe – mm (inch) | 5 x 6.35 (1/4) |
Gas Pipe – mm (inch) | 4 x 9.52 (3/8) + 1 x 12.7 (1/2) | |
Adaptors to connect field pipes are supplied with an outdoor (MRC) unit | STD | |
Wiring Method | Hardwire to Outdoor |
Foot Notes 1-9
- EER Rated = Energy Efficiency Ratio (Rated Capacity Cooling¸ Rated Input Power Cooling)
- COP Rated = Coefficient of Performance (Rated Capacity Heating¸ Rated Power Heating)
- Maximum FLA based on the following combination:
- MRC-075CS-3 + BRE-035CS + BRE-050CS + BRE-050CS
- MRC-100CS-4 + BRE-035CS + BRE-035CS + BRE-035CS + BRE-050CS
- MRC-120CS-5 + BRE-035CS + BRE-035CS + BRE-050CS + BRE-050CS + BRE-050CS
- Each installation will require the calculation of the selected combination (Outdoor + Indoor/s) for the correct full-load amps.
- Based on the MEPS registered combination.
- Refer to AS/NZS 3000 ‘Australian/New Zealand Wiring Rules’ for more details.
- Refer to the Catalogue Unit Weight Distribution Guide section for details of weight points.
- Sound Pressure Level at 1m distance is determined as the measured sound pressure at 1m perpendicular to the coil side of the condenser.
- Determination of Sound Power Levels of Noise Sources, AS1217.2 – Precision Methods for Broad-Band Sources in Reverberation Rooms.
- When the Demand Response capability option is chosen, the air conditioner will be fully compliant with AS4755.3 in the following modes: DRM 1, 2, 3
Important Notes:
- The Local Electricity Supply Authority may require limits on – starting current, running current and voltage drop, please check before purchase.
- When the outdoor temperature exceeds the rated conditions, the cooling/heating capacities may decrease the rated nett values.
- Specifications are subject to change without notice.
X
Reviews (0)
Specifications
OUTDOOR MODEL | MRC-120CS-5 | |
Nett (Rated) Capacity (kW) (AS/NZS3823.1.4) | Cooling (min-max) | 11.85 |
Heating (min-max) | 12.50 | |
Input Power (kW) (AS/NZS3823.1.4) | Cooling Rated | 3.15 |
Heating Rated | 3.25 | |
1 EER Rated (AS/NZS3823.1.4) 2 COP Rated (AS/NZS3823.1.4) |
Cooling Rated | 3.76 |
Heating Rated | 3.85 |
Specifications
OUTDOOR MODEL | MRC-120CS-5 | |
APPLICABLE INDOOR MODEL/S | Wall Hung | WRE-026CS |
WRE-035CS | ||
WRE-050CS | ||
WRE-072CS | ||
WRE-085CS | ||
Bulkhead | BRE-026CS | |
BRE-035CS | ||
BRE-050CS | ||
BRE-070CS | ||
Mini-Cassette | MRE-035CS | |
MRE-050CS | ||
Nett (Rated) Capacity (kW) (AS/NZS3823.1.4) | Cooling (min-max) | 11.85 |
Heating (min-max) | 12.50 | |
Input Power (kW) (AS/NZS3823.1.4) | Cooling Rated | 3.15 |
Heating Rated | 3.25 | |
1 EER Rated (AS/NZS3823.1.4) 2 COP Rated (AS/NZS3823.1.4) |
Cooling Rated | 3.76 |
Heating Rated | 3.85 | |
Power Supply – (V / Ph / Hz) | Outdoor | 220 – 240 V / 1Ph+N / 50Hz |
Rated Load Amps (AS/NZS3823.1.4) | Cooling | 14.7 |
Heating | 15.8 | |
Full Load Amps | 3 Maximum possible combination | 26.4 |
Outdoor Unit Only | 19.0 | |
4 Circuit Breaker Amps and Main Cable Amps | 32.0 | |
5 Suggested Minimum Indoor to Outdoor Cable Size & Type | ||
IP Rating | Outdoor | IPX4 |
Compressor Type | Inverter Twin-Rotary | |
Refrigerant | R32 | |
Outdoor Dimensions (mm) | Depth | 410 |
Height | 810 | |
Width | 946 | |
6 Nominal Weight (kgs) | Outdoor | 75.9 |
7 Outdoor Sound Pressure Level (dBA) 1m | 62.6 | |
8 Outdoor Sound Power Level (dBA) | 73 | |
Outdoor Operating Range (°C) | Cooling | -15°C to 50°C |
Heating | -25°C to 30°C | |
MEPS Compliant | YES | |
Technical Information | ||
Refrigerant Charge | Factory Charge – (g) | 2950 |
Pre-Charge Length – (m) | 5 x 10m | |
Additional Refrigerant Charge – (g/m) | 12 | |
Minimum Field Pipe Length – (m) | 1 indoor unit | 12 |
Maximum Field Pipe Length – (m) | For all rooms | 80 |
For 1 indoor unit | 35 | |
Maximum Vertical Height Differential (m) included in max length | From OD unit to ID unit | 15 |
From ID unit to ID unit | 15 | |
Outdoor Unit Connections | Liquid Pipe – mm (inch) | 5 x 6.35 (1/4) |
Gas Pipe – mm (inch) | 4 x 9.52 (3/8) + 1 x 12.7 (1/2) | |
Adaptors to connect field pipes are supplied with an outdoor (MRC) unit | STD | |
Wiring Method | Hardwire to Outdoor |
Foot Notes 1-9
- EER Rated = Energy Efficiency Ratio (Rated Capacity Cooling¸ Rated Input Power Cooling)
- COP Rated = Coefficient of Performance (Rated Capacity Heating¸ Rated Power Heating)
- Maximum FLA based on the following combination:
- MRC-075CS-3 + BRE-035CS + BRE-050CS + BRE-050CS
- MRC-100CS-4 + BRE-035CS + BRE-035CS + BRE-035CS + BRE-050CS
- MRC-120CS-5 + BRE-035CS + BRE-035CS + BRE-050CS + BRE-050CS + BRE-050CS
- Each installation will require the calculation of the selected combination (Outdoor + Indoor/s) for the correct full-load amps.
- Based on the MEPS registered combination.
- Refer to AS/NZS 3000 ‘Australian/New Zealand Wiring Rules’ for more details.
- Refer to the Catalogue Unit Weight Distribution Guide section for details of weight points.
- Sound Pressure Level at 1m distance is determined as the measured sound pressure at 1m perpendicular to the coil side of the condenser.
- Determination of Sound Power Levels of Noise Sources, AS1217.2 – Precision Methods for Broad-Band Sources in Reverberation Rooms.
- When the Demand Response capability option is chosen, the air conditioner will be fully compliant with AS4755.3 in the following modes: DRM 1, 2, 3
Important Notes:
- The Local Electricity Supply Authority may require limits on – starting current, running current and voltage drop, please check before purchase.
- When the outdoor temperature exceeds the rated conditions, the cooling/heating capacities may decrease the rated nett values.
- Specifications are subject to change without notice.