Actronair MultiElite Series 2 - MRC-075CS-3 7.5 kW Outdoor Unit Only One phase R32-3 Heads
MRC-075CS-3
Price: (Inc GST)
- SKU: MRC-075CS-3
- Cooling: 7.5 kW
- Heating: 7.6 kW
- Actronair MultiElite Series 2 – MRC-075CS-3 7.5 kW Outdoor Unit Only One phase R32-3 Heads
- Wired Wall Controller – WC-02 Included
- Built In Drain Pump Included
Key Features
Capacity to suit your needs
Coated Coil Protection
Different temperatures in different rooms
Easy installation and commissioning
Specifications
OUTDOOR MODEL | MRC-075CS-3 | |
Net (Rated) Capacity (kW) (AS/NZS3823.1.4) | Cooling (min-max) | 7.50 |
Heating (min-max) | 7.60 | |
Input Power (kW) (AS/NZS3823.1.4) | Cooling Rated | 1.90 |
Heating Rated | 1.60 | |
1 EER Rated (AS/NZS3823.1.4) 2 COP Rated (AS/NZS3823.1.4) |
Cooling Rated | 3.95 |
Heating Rated | 4.75 |
Specifications
OUTDOOR MODEL | MRC-075CS-3 | |
APPLICABLE INDOOR MODEL/S | Wall Hung | WRE-026CS |
WRE-035CS | ||
WRE-050CS | ||
WRE-072CS | ||
– | ||
Bulkhead | BRE-026CS | |
BRE-035CS | ||
BRE-050CS | ||
BRE-070CS | ||
Mini-Cassette | MRE-035CS | |
MRE-050CS | ||
Nett (Rated) Capacity (kW) (AS/NZS3823.1.4) | Cooling (min-max) | 7.50 |
Heating (min-max) | 7.60 | |
Input Power (kW) (AS/NZS3823.1.4) | Cooling Rated | 1.90 |
Heating Rated | 1.60 | |
1 EER Rated (AS/NZS3823.1.4) 2 COP Rated (AS/NZS3823.1.4) |
Cooling Rated | 3.95 |
Heating Rated | 4.75 | |
Power Supply – (V / Ph / Hz) | Outdoor | |
Rated Load Amps (AS/NZS3823.1.4) | Cooling | 8.4 |
Heating | 7.0 | |
Full Load Amps | 3 Maximum possible combination | 21.0 |
Outdoor Unit Only | 17.5 | |
4 Circuit Breaker Amps and Main Cable Amps | 25.0 | |
5 Suggested Minimum Indoor to Outdoor Cable Size & Type | 1.0mm2 3 Core + Earth |
|
IP Rating | Outdoor | IP24 |
Compressor Type | Inverter Twin-Rotary | |
Refrigerant | R32 | |
Outdoor Dimensions (mm) | Depth | 342 |
Height | 673 | |
Width | 890 | |
6 Nominal Weight (kgs) | Outdoor | 48.1 |
7 Outdoor Sound Pressure Level (dBA) 1m | 58.7 | |
8 Outdoor Sound Power Level (dBA) | 65 | |
Outdoor Operating Range (°C) | Cooling | -15°C to 50°C |
Heating | -25°C to 30°C | |
MEPS Compliant | Yes | |
Technical Information | ||
Refrigerant Charge | Factory Charge – (g) | 1850 |
Pre-Charge Length – (m) | 3 x 10m | |
Additional Refrigerant Charge – (g/m) | 12 | |
Minimum Field Pipe Length – (m) | 1 indoor unit | 9 |
Maximum Field Pipe Length – (m) | For all rooms | 60 |
For 1 indoor unit | 30 | |
Maximum Vertical Height Differential (m) included in max length | From OD unit to ID unit | 15 |
From ID unit to ID unit | 15 | |
Outdoor Unit Connections | Liquid Pipe – mm (inch) | 3 x 6.35 (1/4) |
Gas Pipe – mm (inch) | 3 x 9.52 (3/8) | |
Adaptors to connect field pipes are supplied with an outdoor (MRC) unit | STD | |
Wiring Method | Hardwire to Outdoor |
Foot Notes 1-9
- EER Rated = Energy Efficiency Ratio (Rated Capacity Cooling¸ Rated Input Power Cooling)
- COP Rated = Coefficient of Performance (Rated Capacity Heating¸ Rated Power Heating)
- Maximum FLA based on the following combination:
- MRC-075CS-3 + BRE-035CS + BRE-050CS + BRE-050CS
- MRC-100CS-4 + BRE-035CS + BRE-035CS + BRE-035CS + BRE-050CS
- MRC-120CS-5 + BRE-035CS + BRE-035CS + BRE-050CS + BRE-050CS + BRE-050CS
- Each installation will require the calculation of the selected combination (Outdoor + Indoor/s) for the correct full-load amps.
- Based on the MEPS registered combination.
- Refer to AS/NZS 3000 ‘Australian/New Zealand Wiring Rules’ for more details.
- Refer to the Catalogue Unit Weight Distribution Guide section for details of weight points.
- Sound Pressure Level at 1m distance is determined as the measured sound pressure at 1m perpendicular to the coil side of the condenser.
- Determination of Sound Power Levels of Noise Sources, AS1217.2 – Precision Methods for Broad-Band Sources in Reverberation Rooms.
- When the Demand Response capability option is chosen, the air conditioner will be fully compliant with AS4755.3 in the following modes: DRM 1, 2, 3
Important Notes:
- The Local Electricity Supply Authority may require limits on – starting current, running current and voltage drop, please check before purchase.
- When the outdoor temperature exceeds the rated conditions, the cooling/heating capacities may decrease the rated nett values.
- Specifications are subject to change without notice.
X
Reviews (0)
Specifications
OUTDOOR MODEL | MRC-075CS-3 | |
Net (Rated) Capacity (kW) (AS/NZS3823.1.4) | Cooling (min-max) | 7.50 |
Heating (min-max) | 7.60 | |
Input Power (kW) (AS/NZS3823.1.4) | Cooling Rated | 1.90 |
Heating Rated | 1.60 | |
1 EER Rated (AS/NZS3823.1.4) 2 COP Rated (AS/NZS3823.1.4) |
Cooling Rated | 3.95 |
Heating Rated | 4.75 |
Specifications
OUTDOOR MODEL | MRC-075CS-3 | |
APPLICABLE INDOOR MODEL/S | Wall Hung | WRE-026CS |
WRE-035CS | ||
WRE-050CS | ||
WRE-072CS | ||
– | ||
Bulkhead | BRE-026CS | |
BRE-035CS | ||
BRE-050CS | ||
BRE-070CS | ||
Mini-Cassette | MRE-035CS | |
MRE-050CS | ||
Nett (Rated) Capacity (kW) (AS/NZS3823.1.4) | Cooling (min-max) | 7.50 |
Heating (min-max) | 7.60 | |
Input Power (kW) (AS/NZS3823.1.4) | Cooling Rated | 1.90 |
Heating Rated | 1.60 | |
1 EER Rated (AS/NZS3823.1.4) 2 COP Rated (AS/NZS3823.1.4) |
Cooling Rated | 3.95 |
Heating Rated | 4.75 | |
Power Supply – (V / Ph / Hz) | Outdoor | |
Rated Load Amps (AS/NZS3823.1.4) | Cooling | 8.4 |
Heating | 7.0 | |
Full Load Amps | 3 Maximum possible combination | 21.0 |
Outdoor Unit Only | 17.5 | |
4 Circuit Breaker Amps and Main Cable Amps | 25.0 | |
5 Suggested Minimum Indoor to Outdoor Cable Size & Type | 1.0mm2 3 Core + Earth |
|
IP Rating | Outdoor | IP24 |
Compressor Type | Inverter Twin-Rotary | |
Refrigerant | R32 | |
Outdoor Dimensions (mm) | Depth | 342 |
Height | 673 | |
Width | 890 | |
6 Nominal Weight (kgs) | Outdoor | 48.1 |
7 Outdoor Sound Pressure Level (dBA) 1m | 58.7 | |
8 Outdoor Sound Power Level (dBA) | 65 | |
Outdoor Operating Range (°C) | Cooling | -15°C to 50°C |
Heating | -25°C to 30°C | |
MEPS Compliant | Yes | |
Technical Information | ||
Refrigerant Charge | Factory Charge – (g) | 1850 |
Pre-Charge Length – (m) | 3 x 10m | |
Additional Refrigerant Charge – (g/m) | 12 | |
Minimum Field Pipe Length – (m) | 1 indoor unit | 9 |
Maximum Field Pipe Length – (m) | For all rooms | 60 |
For 1 indoor unit | 30 | |
Maximum Vertical Height Differential (m) included in max length | From OD unit to ID unit | 15 |
From ID unit to ID unit | 15 | |
Outdoor Unit Connections | Liquid Pipe – mm (inch) | 3 x 6.35 (1/4) |
Gas Pipe – mm (inch) | 3 x 9.52 (3/8) | |
Adaptors to connect field pipes are supplied with an outdoor (MRC) unit | STD | |
Wiring Method | Hardwire to Outdoor |
Foot Notes 1-9
- EER Rated = Energy Efficiency Ratio (Rated Capacity Cooling¸ Rated Input Power Cooling)
- COP Rated = Coefficient of Performance (Rated Capacity Heating¸ Rated Power Heating)
- Maximum FLA based on the following combination:
- MRC-075CS-3 + BRE-035CS + BRE-050CS + BRE-050CS
- MRC-100CS-4 + BRE-035CS + BRE-035CS + BRE-035CS + BRE-050CS
- MRC-120CS-5 + BRE-035CS + BRE-035CS + BRE-050CS + BRE-050CS + BRE-050CS
- Each installation will require the calculation of the selected combination (Outdoor + Indoor/s) for the correct full-load amps.
- Based on the MEPS registered combination.
- Refer to AS/NZS 3000 ‘Australian/New Zealand Wiring Rules’ for more details.
- Refer to the Catalogue Unit Weight Distribution Guide section for details of weight points.
- Sound Pressure Level at 1m distance is determined as the measured sound pressure at 1m perpendicular to the coil side of the condenser.
- Determination of Sound Power Levels of Noise Sources, AS1217.2 – Precision Methods for Broad-Band Sources in Reverberation Rooms.
- When the Demand Response capability option is chosen, the air conditioner will be fully compliant with AS4755.3 in the following modes: DRM 1, 2, 3
Important Notes:
- The Local Electricity Supply Authority may require limits on – starting current, running current and voltage drop, please check before purchase.
- When the outdoor temperature exceeds the rated conditions, the cooling/heating capacities may decrease the rated nett values.
- Specifications are subject to change without notice.
Review Actronair MultiElite Series 2 – MRC-075CS-3 7.5 kW Outdoor Unit Only One phase R32-3 Heads