ActronAir CRS13AS/EVA13AS 13.02 kW Aires Split Ducted System–Single Phase

CRS13AS / EVA13AS

Price: (Inc GST)

  • ActronAir
  • 5 Years
  • In stock

7 capacity. you are choosing 12-14 kw

  • SKU: CRS13AS / EVA13AS
  • Cooling: 13.02 kW
  • Heating: 15.00  kW
  • ActronAir  CRS13AS / EVA13AS 13.02kW Split Ducted System – Single Phase
  • Outdoor Single Phase (Excludes Wired Controller)
  • Includes 7 day wall controller (White/Grey) – 8 Zone & 20m CAT5E Cable – Yellow
  • Optional NEO Controller : NEO TOUCH Master Wall Controller (Black/White)

Optional available Supply Air Vbox:

PL13R-2/35S – RETURN PLENUM – 2 x 350mm (14″) spigot

PL18S-2/35S – SUPPLY PLENUM – 2 x 350mm (14″) spigot

PL20S-2/40S – SUPPLY PLENUM – 2 x 400mm (16″) spigot

PL13S-3/30S – SUPPLY PLENUM – 3 x 300mm (12″) spigot

PL18S-3/35S – SUPPLY PLENUM – 3 x 350mm (14″) spigot

PL20S-3/SPS – SUPPLY PLENUM – 1 x 400mm (16″) / 2 x 350 (14″) spigot

KEY FEATURES

Integrated zone card

All indoor units come with integrated zoning ready for up to 8 zones.

Efficient EC Indoor Fan

The AIRES range uses a highly efficient EC indoor fan to deliver precise comfort control, smoother operation, and quieter starting and stopping.

Safety Drain Tray included as standard

Removes the need to purchase as an additional accessory.

Performance

Enhanced Performance

With its DC inverter technology, which allows its compressor to modulate, the AIRES system is able to deliver smooth capacity transitions to meet your heating and cooling demands.

Turbo Mode

Stay comfortable even on the scorching Aussie summer days or chilly winter mornings with our Turbo Mode function. Feel the instant relief as your air conditioner kicks into high gear, delivering extra capacity power when you need it most.

Engineered for Australia

AIRES air conditioners are specifically made for Australian weather conditions, which can exceed temperatures of 46°C. Unlike most overseas air conditioners with a maximum operating temperature range of 43°C to 46°C, AIRES units operate up to 50°C.*

*Operating range based on air temperature entering the outdoor unit heat exchanger

Quiet Operation

Comfort comes not only in how you feel but also in what you hear, or with the AIRES, what you don’t hear. Using the latest technologies such as variable speed DC Inverters, modulating DC outdoor fans, and smooth operating EC indoor fans, the AIRES has been designed with your noise comfort in mind.

Australian Made Comfort

Experience the peace of mind that comes with Australian-made controls and a thoughtfully designed indoor unit, complete with zoning designed for how Australians truly live.

    Submit your consultation request

    Rules

    • GenuineGenuine Brand new
      100% original, original quality warranty
    • Customer Care
      Customer care
      After-sales, thoughtful support

    Specifications

    Model Outdoor CRS13AS
    Indoor EVA13AS
    (1)Total (Gross) Capacity (kW) (AS/NZS3823.1.2) Cooling (Rated) 13.30
    Heating (Rated) 14.70
    Nett (Rated) Capacity (kW) (AS/NZS3823.1.2) Cooling (Min/Rated/Max) 5.55 / 13.02 / 15.01
    Heating (Min/Rated/Max) 4.69 / 15.00 / 17.03

    Specifications

    Model Outdoor CRS13AS
    Indoor EVA13AS
    (1)Total (Gross) Capacity (kW) (AS/NZS3823.1.2) Cooling (Rated) 13.30
    Heating (Rated) 14.70
    Nett (Rated) Capacity (kW) (AS/NZS3823.1.2) Cooling (Min/Rated/Max) 5.55 / 13.02 / 15.01
    Heating (Min/Rated/Max) 4.69 / 15.00 / 17.03
    Input Power (kW) (AS/NZS3823.1.2) Cooling (Rated) 3.89
    Heating (Rated) 4.27
    (2)EER Rated (AS/NZS3823.1.2) Cooling (Rated) 3.35
    (3)COP Rated (AS/NZS3823.1.2) Heating (Rated) 3.51
    Seasonal Performance Factor Residential TCSPF (Hot/Mixed/Cold) 4.42 / 4.00 / 4.08
    HSPF (Hot/Mixed/Cold) 4.33 / 3.86 / 3.42
    Power Supply – (V/Ph/Hz) Outdoor 230V / 1Ph + N- / 50Hz
    Indoor 230V / 1Ph + N- / 50Hz
    Rated Amps (AS/NZS3823.1.2) Total 18.60
    Full Load Amps (AS/NZS3823.1.2) Outdoor / Indoor / Total 17.70 / 4.30 / 22.00
    (4)Circuit Breaker Amps (Suggested) 25.00
    IP Rating Outdoor IPX4
    Indoor IP20
    Compressor Type / No. Unit Inverter Twin Rotary/1
    Starting Method Variable Speed Drive
    No. of Refrigeration Circuits / No. of Capacity Stages 1/Variable Capacity
    Refrigerant R32
    Fans (Type x Number per Unit) Outdoor Axial / DC Motor x 1
    Indoor Twin Centrifugal / EC Motor x 2
    Airflow Indoor (l/s) Maximum 780
    Nominal 650
    Minimum 520
    Outdoor Dimensions (mm) Depth 358
    Height 997
    Width 1020
    Indoor Dimensions (mm) Depth 615
    Height 412
    Width 1090
    (5)Nominal Weights (kgs) Outdoor 85
    Indoor 44
    (6)Sound Pressure Level (dBA) @ 3m Outdoor (quiet/rated/max) 47.0 / 54.2 / 55.2
    (7)Sound Power Level (dBA) Outdoor (quiet/rated/max) 64.2 / 70.0 / 71.0
    MEPS Compliant Yes
    Demand Response Capability (AS4755.3) Yes
    BMS and Home Automation Compatibility (ICUNO-MOD) Yes
    Hydrophilic Blue Fin Coil Coat Protection – Indoor & Outdoor Coils Yes
    Home Automation / Remote On / Off Capability Yes
    Manual Inputs Capable for Third-party Control Yes
    Maximum Number of Zones 8
    Run & Fault Indication Yes
    Two Piece Indoor Option Yes

    Foot Notes 1-14
    1. Based on unit rating excluding indoor fan kW.
    2. EER Rated = Energy Efficiency Ratio (Rated Capacity Cooling / Rated Input Cooling).
    3. COP Rated = Coefficient of Performance (Rated Capacity Heating / Rated Input Heating).
    4. Refer to AS/NZS 3000 “Australian/New Zealand Wiring Rules” for more details.
    5. Refer to the Catalogue Unit Weight Distribution Guide section for details of weight points.
    6. Sound Pressure Level at 3m distance is determined as the measured sound pressure at 3m perpendicular to the coil side of the condenser. Sound levels are determined in an anechoic chamber and may differ once the unit is installed due to ambient conditions.
    7. Measured based on ISO 3743-1, Determination of Sound Power Levels and Sound Energy Levels of Noise Sources Using Sound Pressure.

    8. Near Field Communications require a compatible device. Provide access to
    wall control operating instructions
    9. Wi-Fi compatibility with 802.11 b/g/n 2.4 GHz
    10. NEO Touch must be connected to Wi-Fi with internet and cloud access
    11. NEO Sense is available for us as wired or wireless. Wireless operation requires 3 x AAA batteries (up to 5 Year battery life)
    12. Portable stand compatible with wireless Neo Sense only
    13. Near Field Communication (NFC) requires a compatible device. Provides access to NEO Connect Mobile App.
    14. Compatible with ActronAir NEO Touch Controller (NTW-1000, NTB-1000). Available on iOS 9 or later / Android Version 6 Marshmallow or later.

     

    X

    Reviews (0)

    Review ActronAir CRS13AS/EVA13AS 13.02 kW Aires Split Ducted System–Single Phase

    5 0% | 0 reviews
    4 0% | 0 reviews
    3 0% | 0 reviews
    2 0% | 0 reviews
    1 0% | 0 reviews
    Review ActronAir CRS13AS/EVA13AS 13.02 kW Aires Split Ducted System–Single Phase

    Note: For reviews to be approved, please refer to Terms & Conditions

    Specifications

    Model Outdoor CRS13AS
    Indoor EVA13AS
    (1)Total (Gross) Capacity (kW) (AS/NZS3823.1.2) Cooling (Rated) 13.30
    Heating (Rated) 14.70
    Nett (Rated) Capacity (kW) (AS/NZS3823.1.2) Cooling (Min/Rated/Max) 5.55 / 13.02 / 15.01
    Heating (Min/Rated/Max) 4.69 / 15.00 / 17.03

    Specifications

    Model Outdoor CRS13AS
    Indoor EVA13AS
    (1)Total (Gross) Capacity (kW) (AS/NZS3823.1.2) Cooling (Rated) 13.30
    Heating (Rated) 14.70
    Nett (Rated) Capacity (kW) (AS/NZS3823.1.2) Cooling (Min/Rated/Max) 5.55 / 13.02 / 15.01
    Heating (Min/Rated/Max) 4.69 / 15.00 / 17.03
    Input Power (kW) (AS/NZS3823.1.2) Cooling (Rated) 3.89
    Heating (Rated) 4.27
    (2)EER Rated (AS/NZS3823.1.2) Cooling (Rated) 3.35
    (3)COP Rated (AS/NZS3823.1.2) Heating (Rated) 3.51
    Seasonal Performance Factor Residential TCSPF (Hot/Mixed/Cold) 4.42 / 4.00 / 4.08
    HSPF (Hot/Mixed/Cold) 4.33 / 3.86 / 3.42
    Power Supply – (V/Ph/Hz) Outdoor 230V / 1Ph + N- / 50Hz
    Indoor 230V / 1Ph + N- / 50Hz
    Rated Amps (AS/NZS3823.1.2) Total 18.60
    Full Load Amps (AS/NZS3823.1.2) Outdoor / Indoor / Total 17.70 / 4.30 / 22.00
    (4)Circuit Breaker Amps (Suggested) 25.00
    IP Rating Outdoor IPX4
    Indoor IP20
    Compressor Type / No. Unit Inverter Twin Rotary/1
    Starting Method Variable Speed Drive
    No. of Refrigeration Circuits / No. of Capacity Stages 1/Variable Capacity
    Refrigerant R32
    Fans (Type x Number per Unit) Outdoor Axial / DC Motor x 1
    Indoor Twin Centrifugal / EC Motor x 2
    Airflow Indoor (l/s) Maximum 780
    Nominal 650
    Minimum 520
    Outdoor Dimensions (mm) Depth 358
    Height 997
    Width 1020
    Indoor Dimensions (mm) Depth 615
    Height 412
    Width 1090
    (5)Nominal Weights (kgs) Outdoor 85
    Indoor 44
    (6)Sound Pressure Level (dBA) @ 3m Outdoor (quiet/rated/max) 47.0 / 54.2 / 55.2
    (7)Sound Power Level (dBA) Outdoor (quiet/rated/max) 64.2 / 70.0 / 71.0
    MEPS Compliant Yes
    Demand Response Capability (AS4755.3) Yes
    BMS and Home Automation Compatibility (ICUNO-MOD) Yes
    Hydrophilic Blue Fin Coil Coat Protection – Indoor & Outdoor Coils Yes
    Home Automation / Remote On / Off Capability Yes
    Manual Inputs Capable for Third-party Control Yes
    Maximum Number of Zones 8
    Run & Fault Indication Yes
    Two Piece Indoor Option Yes

    Foot Notes 1-14
    1. Based on unit rating excluding indoor fan kW.
    2. EER Rated = Energy Efficiency Ratio (Rated Capacity Cooling / Rated Input Cooling).
    3. COP Rated = Coefficient of Performance (Rated Capacity Heating / Rated Input Heating).
    4. Refer to AS/NZS 3000 “Australian/New Zealand Wiring Rules” for more details.
    5. Refer to the Catalogue Unit Weight Distribution Guide section for details of weight points.
    6. Sound Pressure Level at 3m distance is determined as the measured sound pressure at 3m perpendicular to the coil side of the condenser. Sound levels are determined in an anechoic chamber and may differ once the unit is installed due to ambient conditions.
    7. Measured based on ISO 3743-1, Determination of Sound Power Levels and Sound Energy Levels of Noise Sources Using Sound Pressure.

    8. Near Field Communications require a compatible device. Provide access to
    wall control operating instructions
    9. Wi-Fi compatibility with 802.11 b/g/n 2.4 GHz
    10. NEO Touch must be connected to Wi-Fi with internet and cloud access
    11. NEO Sense is available for us as wired or wireless. Wireless operation requires 3 x AAA batteries (up to 5 Year battery life)
    12. Portable stand compatible with wireless Neo Sense only
    13. Near Field Communication (NFC) requires a compatible device. Provides access to NEO Connect Mobile App.
    14. Compatible with ActronAir NEO Touch Controller (NTW-1000, NTB-1000). Available on iOS 9 or later / Android Version 6 Marshmallow or later.

     