ActronAir CRA170S 16.8 kW Classic Fixed Speed Ducted AC System 1 Phase
CRA170S / EVA170S
Price: (Inc GST)
- SKU: CRA170S / EVA170S
- Cooling: 16.8 kW
- Heating: 17.57 kW
- ActronAir CRA170S 16.8 kW Classic Fixed Speed Ducted AC System 1 Phase
- CRA170S – Outdoor Single Phase (Excludes Wired Controller)
- EVA170S Indoor – Includes 8 Zones integrated & 20m Data cable for controller
- LR7-1W/G -7 day wall controller (White/Grey) 8 Zone
- 5 years full manufacturer warranty on Parts and Labour.
Optional available Supply Air Vbox:
PL18R-2/35S – RETURN PLENUM – 2 x 350mm (14″) spigot
PL20R-2/40S – RETURN PLENUM – 2 x 400mm (16″) spigot
PL18S-2/35S – SUPPLY PLENUM – 2 x 350mm (14″) spigot
PL20S-2/40S – SUPPLY PLENUM – 2 x 400mm (16″) spigot
PL13S-3/30S – SUPPLY PLENUM – 3 x 300mm (12″) spigot
PL18S-3/35S – SUPPLY PLENUM – 3 x 350mm (14″) spigot
PL20S-3/SPS – SUPPLY PLENUM – 1 x 400mm (16″) / 2 x 350 (14″) spigot
Better Features
Vertical discharge
The Classic’s clever outdoor unit features a vertical, rather than horizontal, discharge of air. Unlike most overseas brands, we’re well aware that the side of the Australian home is not only
a handy space for an outdoor unit, but is also often tight. We know if you don’t let hot air escape will surround the unit, reducing its performance and in turn leading to higher energy
consumption. That’s why we’ve engineered the Classic to release hot air upwards, rather than pushing air straight into the neighbour’s fence.
Unheard of technology
Efficient EC fan
The highly efficient EC fan used in our Classic range delivers superior airflow, with quieter starting and stopping, making it perfect for sleeping babies or shift workers
Here for the long haul
Coated coil protection
ActronAir uses Hydrophilic Blue Fin Coil Coat Protection on the Classic’s indoor and outdoor coils. It reduces corrosion from harsh
Australian conditions, as well as assisting the defrosting process, thus improving the heating efficiency.
Better Zoning = Energy Efficiency and Comfort
What’s zoning and why do I need it?
Zoning is a pretty straightforward idea. You simply divide your home into smaller areas that can then be conditioned individually, letting you turn them on and off to suit you, which provides better comfort and greater energy efficiency. Think of lights in a home – when you leave a room you turn off the light to save electricity, right? Well, zoning allows you to do the same with your air conditioning.
Better Performance
Engineered for Australia
Made with a superior operating range of -10ºC to 50ºC, and a host of innovative features, ActronAir’s Classic ducted system is engineered to withstand the hottest and coldest conditions Australia can throw at it.
Where other air conditioners struggle and shut down, the Classic will be there for you when you need it most
Better Service
Local service you can count on
Our Classic is designed and manufactured in Australia, so you’ll never have to call far or wait long for service and support.
Our National Service Network has service staff on the ground and parts on the shelves. They’re friendly, reliable and prompt.
Furthermore, ActronAir’s 5-year warranty will keep you comfortable with absolute peace of mind.
Better Controls
The best analogue control on the market
Available in your choice of grey or white and featuring an attractive and easy-to-use design, the L Series comes packed with features such as NFC and integrated zoning. Finally, we believe the best results come when the controller and the air conditioner are designed with each other in mind – that approach is why the L Series operates seamlessly on the Classic Series 2 series to provide optimum control and performance.
Specifications
OUTDOOR MODEL | CRA170S | |
INDOOR MODEL | EVA170S | |
1 Total (Gross) Capacity (kW) (AS/NZS3823.1.2) | Cooling (Rated) | 17.38 |
Heating (Rated) | 17.02 | |
Nett (Rated) Capacity (kW) (AS/NZS3823.1.2) | Cooling | 16.80 |
Heating | 17.57 |
Specifications
OUTDOOR MODEL | CRA170S | |
INDOOR MODEL | EVA170S | |
1 Total (Gross) Capacity (kW) (AS/NZS3823.1.2) | Cooling (Rated) | 17.38 |
Heating (Rated) | 17.02 | |
Nett (Rated) Capacity (kW) (AS/NZS3823.1.2) | Cooling | 16.80 |
Heating | 17.57 | |
Input Power (kW) (AS/NZS3823.1.2) | Cooling | 5.15 |
Heating | 4.76 | |
2 EER Rated (AS/NZS3823.1.2) 3 COP Rated (AS/NZS3823.1.2) |
Cooling | 3.26 |
Heating | 3.69 | |
Power Supply (V/Ph/Hz) | Outdoor | 230V/1Ph + N/50Hz |
Indoor | 230V/1Ph + N/50Hz | |
Rated Load Amps (AS/NZS3823.1.2) Full Load Amps (AS/NZS3823.1.2) |
Outdoor/Indoor/Total | 19.7/4.3/24.0 |
Outdoor/Indoor/Total | 30.7/4.3/35.0 | |
4 Circuit Breaker Amps | 40.0 | |
IP Rating | Outdoor | IP44 |
Indoor | IP20 | |
Compressor | Type/No. per Unit | Compliant Scroll/1 |
Starting Method | Soft Starter | |
No. Refrigeration Circuits/No. Capacity Stages (Capacity range) | 1/1 (100% capacity) | |
Refrigerant | R410A | |
Fans (Type x Number per unit) |
Outdoor | Axial/6 Pole External Rotor/Direct Drive x 2 |
Indoor | Twin Deck Centrifugal/ECM Direct Drive x 1 | |
Airflow Range Indoor (l/s) | Maximum | 900 |
Nominal | 850 | |
Minimum | 770 | |
External Static Pressure (Pa) at: | Maximum Airflow | 116 |
Nominal Airflow | 164 | |
Outdoor Dimensions (mm) | Depth | 580 |
Height | 1045 | |
Width | 1460 | |
Indoor Dimensions (mm) | Depth | 615 |
Height | 412 | |
Width | 1290 | |
5 Nominal Weight (kgs) | Outdoor | 156 |
Indoor | 56 | |
6 Sound Pressure Level (dBA) | Outdoor (low/med/high fan) | 50.4/51.3/53.1 |
7 Sound Power Level (dBA) | Outdoor (low/med/high fan) |
69.8/70.7/73.1 |
MEPS Compliant | Yes | |
8 Demand Response Capability (AS4755.3) | Capable |
Foot Notes 1-8
1. Based on unit rating excluding indoor fan kW.
2. EER Rated = Energy Efficiency Ratio (Rated Capacity Cooling / Rated Input Cooling).
3. COP Rated = Coefficient of Performance (Rated Capacity Heating / Rated Input Heating).
4. Refer to AS/NZS 3000 “Australian/New Zealand Wiring Rules” for more details.
5. Refer to the Catalogue Unit Weight Distribution Guide section for details of weight points.
6. Sound Pressure Level at 3m distance is determined as the measured sound pressure at 3m perpendicular to the coil side of the condenser. Sound levels are determined in an anechoic chamber and may differ once the unit is installed due to ambient conditions.
7. Measured based on ISO 3743-1, Determination of Sound Power Levels and Sound Energy Levels of Noise Sources Using Sound Pressure.
8. Third-party inputs and Remote ON/OFF functions will be lost if the Demand Response outdoor board is installed.
Important Notes:
• The Local Electricity Supply Authority may require limits on – starting current, running current, and voltage drop, please check before purchase.
• When the outdoor temperature exceeds the rated conditions, the cooling/heating capacities may decrease the rated nett values.
Rated Conditions:
Cooling: 35°C DB Outdoor / Air Entering Indoor 27°C DB, 19°C WB Heating: 7°C DB, 6°C WB Outdoor / Air Entering Indoor 20°C DB Warranty:
For full terms and conditions of ActronAir warranty, please refer to the warranty terms document – www. actronair.com.au
• Specifications are subject to change without notice.
Reviews (0)
Specifications
OUTDOOR MODEL | CRA170S | |
INDOOR MODEL | EVA170S | |
1 Total (Gross) Capacity (kW) (AS/NZS3823.1.2) | Cooling (Rated) | 17.38 |
Heating (Rated) | 17.02 | |
Nett (Rated) Capacity (kW) (AS/NZS3823.1.2) | Cooling | 16.80 |
Heating | 17.57 |
Specifications
OUTDOOR MODEL | CRA170S | |
INDOOR MODEL | EVA170S | |
1 Total (Gross) Capacity (kW) (AS/NZS3823.1.2) | Cooling (Rated) | 17.38 |
Heating (Rated) | 17.02 | |
Nett (Rated) Capacity (kW) (AS/NZS3823.1.2) | Cooling | 16.80 |
Heating | 17.57 | |
Input Power (kW) (AS/NZS3823.1.2) | Cooling | 5.15 |
Heating | 4.76 | |
2 EER Rated (AS/NZS3823.1.2) 3 COP Rated (AS/NZS3823.1.2) |
Cooling | 3.26 |
Heating | 3.69 | |
Power Supply (V/Ph/Hz) | Outdoor | 230V/1Ph + N/50Hz |
Indoor | 230V/1Ph + N/50Hz | |
Rated Load Amps (AS/NZS3823.1.2) Full Load Amps (AS/NZS3823.1.2) |
Outdoor/Indoor/Total | 19.7/4.3/24.0 |
Outdoor/Indoor/Total | 30.7/4.3/35.0 | |
4 Circuit Breaker Amps | 40.0 | |
IP Rating | Outdoor | IP44 |
Indoor | IP20 | |
Compressor | Type/No. per Unit | Compliant Scroll/1 |
Starting Method | Soft Starter | |
No. Refrigeration Circuits/No. Capacity Stages (Capacity range) | 1/1 (100% capacity) | |
Refrigerant | R410A | |
Fans (Type x Number per unit) |
Outdoor | Axial/6 Pole External Rotor/Direct Drive x 2 |
Indoor | Twin Deck Centrifugal/ECM Direct Drive x 1 | |
Airflow Range Indoor (l/s) | Maximum | 900 |
Nominal | 850 | |
Minimum | 770 | |
External Static Pressure (Pa) at: | Maximum Airflow | 116 |
Nominal Airflow | 164 | |
Outdoor Dimensions (mm) | Depth | 580 |
Height | 1045 | |
Width | 1460 | |
Indoor Dimensions (mm) | Depth | 615 |
Height | 412 | |
Width | 1290 | |
5 Nominal Weight (kgs) | Outdoor | 156 |
Indoor | 56 | |
6 Sound Pressure Level (dBA) | Outdoor (low/med/high fan) | 50.4/51.3/53.1 |
7 Sound Power Level (dBA) | Outdoor (low/med/high fan) |
69.8/70.7/73.1 |
MEPS Compliant | Yes | |
8 Demand Response Capability (AS4755.3) | Capable |
Foot Notes 1-8
1. Based on unit rating excluding indoor fan kW.
2. EER Rated = Energy Efficiency Ratio (Rated Capacity Cooling / Rated Input Cooling).
3. COP Rated = Coefficient of Performance (Rated Capacity Heating / Rated Input Heating).
4. Refer to AS/NZS 3000 “Australian/New Zealand Wiring Rules” for more details.
5. Refer to the Catalogue Unit Weight Distribution Guide section for details of weight points.
6. Sound Pressure Level at 3m distance is determined as the measured sound pressure at 3m perpendicular to the coil side of the condenser. Sound levels are determined in an anechoic chamber and may differ once the unit is installed due to ambient conditions.
7. Measured based on ISO 3743-1, Determination of Sound Power Levels and Sound Energy Levels of Noise Sources Using Sound Pressure.
8. Third-party inputs and Remote ON/OFF functions will be lost if the Demand Response outdoor board is installed.
Important Notes:
• The Local Electricity Supply Authority may require limits on – starting current, running current, and voltage drop, please check before purchase.
• When the outdoor temperature exceeds the rated conditions, the cooling/heating capacities may decrease the rated nett values.
Rated Conditions:
Cooling: 35°C DB Outdoor / Air Entering Indoor 27°C DB, 19°C WB Heating: 7°C DB, 6°C WB Outdoor / Air Entering Indoor 20°C DB Warranty:
For full terms and conditions of ActronAir warranty, please refer to the warranty terms document – www. actronair.com.au
• Specifications are subject to change without notice.