ActronAir Advance CRV17AT|EVV17AS 17kW Split Ducted System 3 Phase
CRV17AT | EVV17AS
Price: (Inc GST)
- SKU: CRV17AT | EVV17AS
- Cooling: 17.35 kW
- Heating: 18.05kW
- ActronAir Advance CRV17AT | EVV17AS 17kW Split Ducted System | 3 Phase
- CRV17AT: Advance Outdoor Three Phase (Excludes Wired Controller)
- EVV17AS: Advance Indoor -Includes 8 Zones integrated & 20m CAT5E Cable – Yellow
- Includes 7 day wall controller (White/Grey) – 8 Zone
- Optional NEO Controller : NEO TOUCH Master Wall Controller (Black/White)
Optional available Supply Air Vbox:
PL19R-2/40S – RETURN PLENUM – 2 x 400mm (16″) spigot
PL19R-2/45S – RETURN PLENUM – 2 x 450mm (18″) spigot
PL18S-2/35S – SUPPLY PLENUM – 2 x 350mm (14″) spigot
PL20S-2/40S – SUPPLY PLENUM – 2 x 400mm (16″) spigot
PL13S-3/30S – SUPPLY PLENUM – 3 x 300mm (12″) spigot
PL18S-3/35S – SUPPLY PLENUM – 3 x 350mm (14″) spigot
PL20S-3/SPS – SUPPLY PLENUM – 1 x 400mm (16″) / 2 x 350 (14″) spigot
- Indoor Features
Integrated zone card
All indoor units come with integrated zoning ready for up to 8 zones.
Additional sensing points
The Advance can support up to 3 wall controllers and 3 remote sensors, each of which can be assigned to a zone to provide better temperature control for better comfort.
Safety Drain Tray included as standard
Removes the need to purchase as an additional accessory.
Feel better and save money with vertical discharge
In Australia, most outdoor units are installed down the side of the house, up close to a fence. And because we design our systems specifically to suit Australia, our Australian-made ducted units come with vertical discharge which makes them much better suited to typical Australian homes, delivering better comfort, more reliability, and greater energy efficiency.
Engineered for Australia
Made with a superior operating range of -15°C up to 54°C, the advanced ducted system is engineered to withstand the hottest and coldest conditions Australia can throw at it.
Savings that pay for themselves
The energy savings in an Advance system can make a huge difference, delivering performance that is up to 75% more efficient than conventional fixed-speed air conditioners, which over 5 years would save up to $4,500 on your electricity costs for cooling alone.
Variable Fan Technology
Advance can ramp its indoor fan speed as low as 20% to deliver just the right amount of conditioned air, unlike most other systems out there which can typically only get down to 60% at best, forcing you to pay to condition the air you don’t even want
Specifications
OUTDOOR MODEL | CRV17AT | |
INDOOR MODEL | EVV17AS | |
1 Total (Gross) Capacity (kW) (AS/NZS3823.1.2) | Cooling (Rated) | 17.35 |
Heating (Rated) | 18.05 | |
Nett (Rated) Capacity (kW) (AS/NZS3823.1.2) | Cooling (Min/Rated/Trumax) | 4.65 / 17.00 / 18.50 |
Heating (Min/Rated/Trumax) | 5.28 / 18.40 / 18.60 | |
Input Power (kW) (AS/NZS3823.1.2) | Cooling (Rated) | 5.09 |
Heating (Rated) | 5.25 |
Specifications
OUTDOOR MODEL | CRV17AT | |
INDOOR MODEL | EVV17AS-V | |
1 Total (Gross) Capacity (kW) (AS/NZS3823.1.2) | Cooling (Rated) | 17.35 |
Heating (Rated) | CRV17AT | |
Nett (Rated) Capacity (kW) (AS/NZS3823.1.2) | Cooling (Min/Rated/Trumax) | EVV17AS |
Heating (Min/Rated/Trumax) | 17.35 | |
Input Power (kW) (AS/NZS3823.1.2) | Cooling (Rated) | 18.05 |
Heating (Rated) | 4.65 / 17.00 / 18.50 | |
2 EER Rated (AS/NZS3823.1.2) 3 COP Rated (AS/NZS3823.1.2) |
Cooling (Rated) | 5.28 / 18.40 / 18.60 |
Heating (Rated) | 5.09 | |
Power Supply (V / Ph / Hz) | Outdoor | 5.25 |
Indoor | 3.34 | |
Rated Load Amps (AS/NZS3823.1.2) Full Load Amps (AS/NZS3823.1.2) | Total | 3.50 |
Outdoor / Indoor / Total | 400V / 3Ph + N / 50Hz | |
4 Circuit Breaker Amps | 230V / 1Ph + N / 50Hz | |
IP Rating | Outdoor | 9.7 |
Indoor | 13.5 / 4.3 / 17.8 | |
Compressor | Type / No. per Unit | 20.0 |
Starting Method | IP44 | |
No. Refrigeration Circuits/No. Capacity Stages (Capacity range) | IP20 | |
Refrigerant | Inverter Variable Speed Scroll / 1 | |
Operating Range | Inbuilt Soft Starting | |
Fans (Type x Number per unit) | Outdoor | 1 / Variable Capacity |
Indoor | R-32 | |
Airflow Range Indoor (l/s) | Maximum | -10 °C up to 52 °C |
Nominal | Axial / ECM Direct Drive x 2 | |
Minimum 9 | Twin Deck Centrifugal / ECM Direct Drive x 1 | |
Outdoor Dimensions (mm) | Depth | 1060 |
Height | 890 | |
Width | 300 | |
Indoor Dimensions (mm) | Depth | 530 |
Height | 1110 | |
Width | 1365 | |
5 Nominal Weight (kgs) | Outdoor | 680 |
Indoor | 435 | |
6 Sound Pressure Level (dBA) 7 Sound Power Level (dBA) |
Outdoor (low/high fan) | 1420 |
Outdoor (low/high fan) | 155 | |
MEPS Compliant | 61 | |
8 Demand Response Capability (AS4755.3) | 47.4 / 55.9 / 55.9 | |
65.7 / 74.6 / 74.6 | ||
Yes | ||
Capable |
Foot Notes 1-9
1. Based on unit rating excluding indoor fan kW.
2. EER Rated = Energy Efficiency Ratio (Rated Capacity Cooling / Rated Input Cooling).
3. COP Rated = Coefficient of Performance (Rated Capacity Heating / Rated Input Heating).
4. Refer to AS/NZS 3000 “Australian/New Zealand Wiring Rules” for more details.
5. Refer to the Catalogue Unit Weight Distribution Guide section for details of weight points.
6. Sound Pressure Level at 3m distance is determined as the measured sound pressure at 3m perpendicular to the coil side of the condenser. Sound levels are determined in an anechoic chamber and may differ once the unit is installed due to ambient conditions.
7. Measured based on ISO 3743-1, Determination of Sound Power Levels and Sound Energy Levels of Noise Sources Using Sound Pressure.
8. When the Demand Response capability option is chosen, the air conditioner will be fully compliant with AS4755.3 in the following modes: DRM 1, 2, 3.
9. Achieved when operating on Variable Fan Mode.
Important Notes:
• The Local Electricity Supply Authority may require limits on – starting current, running current, and voltage drop, please check before purchase.
• When the outdoor temperature exceeds the rated conditions, the cooling/heating capacities may decrease the rated net values.
• Specifications are subject to change without notice.
• All pictures shown are for illustration purposes only.
Rated Conditions:
Cooling: 35°C DB Outdoor / Air Entering Indoor 27°C DB, 19°C WB Heating: 7°C DB, 6°C WB Outdoor / Air Entering Indoor 20°C DB
Warranty:
For full terms and conditions of the ActronAir warranty, please refer to the warranty terms document
– www.actronair.com.au
Reviews (0)
Specifications
OUTDOOR MODEL | CRV17AT | |
INDOOR MODEL | EVV17AS | |
1 Total (Gross) Capacity (kW) (AS/NZS3823.1.2) | Cooling (Rated) | 17.35 |
Heating (Rated) | 18.05 | |
Nett (Rated) Capacity (kW) (AS/NZS3823.1.2) | Cooling (Min/Rated/Trumax) | 4.65 / 17.00 / 18.50 |
Heating (Min/Rated/Trumax) | 5.28 / 18.40 / 18.60 | |
Input Power (kW) (AS/NZS3823.1.2) | Cooling (Rated) | 5.09 |
Heating (Rated) | 5.25 |
Specifications
OUTDOOR MODEL | CRV17AT | |
INDOOR MODEL | EVV17AS-V | |
1 Total (Gross) Capacity (kW) (AS/NZS3823.1.2) | Cooling (Rated) | 17.35 |
Heating (Rated) | CRV17AT | |
Nett (Rated) Capacity (kW) (AS/NZS3823.1.2) | Cooling (Min/Rated/Trumax) | EVV17AS |
Heating (Min/Rated/Trumax) | 17.35 | |
Input Power (kW) (AS/NZS3823.1.2) | Cooling (Rated) | 18.05 |
Heating (Rated) | 4.65 / 17.00 / 18.50 | |
2 EER Rated (AS/NZS3823.1.2) 3 COP Rated (AS/NZS3823.1.2) |
Cooling (Rated) | 5.28 / 18.40 / 18.60 |
Heating (Rated) | 5.09 | |
Power Supply (V / Ph / Hz) | Outdoor | 5.25 |
Indoor | 3.34 | |
Rated Load Amps (AS/NZS3823.1.2) Full Load Amps (AS/NZS3823.1.2) | Total | 3.50 |
Outdoor / Indoor / Total | 400V / 3Ph + N / 50Hz | |
4 Circuit Breaker Amps | 230V / 1Ph + N / 50Hz | |
IP Rating | Outdoor | 9.7 |
Indoor | 13.5 / 4.3 / 17.8 | |
Compressor | Type / No. per Unit | 20.0 |
Starting Method | IP44 | |
No. Refrigeration Circuits/No. Capacity Stages (Capacity range) | IP20 | |
Refrigerant | Inverter Variable Speed Scroll / 1 | |
Operating Range | Inbuilt Soft Starting | |
Fans (Type x Number per unit) | Outdoor | 1 / Variable Capacity |
Indoor | R-32 | |
Airflow Range Indoor (l/s) | Maximum | -10 °C up to 52 °C |
Nominal | Axial / ECM Direct Drive x 2 | |
Minimum 9 | Twin Deck Centrifugal / ECM Direct Drive x 1 | |
Outdoor Dimensions (mm) | Depth | 1060 |
Height | 890 | |
Width | 300 | |
Indoor Dimensions (mm) | Depth | 530 |
Height | 1110 | |
Width | 1365 | |
5 Nominal Weight (kgs) | Outdoor | 680 |
Indoor | 435 | |
6 Sound Pressure Level (dBA) 7 Sound Power Level (dBA) |
Outdoor (low/high fan) | 1420 |
Outdoor (low/high fan) | 155 | |
MEPS Compliant | 61 | |
8 Demand Response Capability (AS4755.3) | 47.4 / 55.9 / 55.9 | |
65.7 / 74.6 / 74.6 | ||
Yes | ||
Capable |
Foot Notes 1-9
1. Based on unit rating excluding indoor fan kW.
2. EER Rated = Energy Efficiency Ratio (Rated Capacity Cooling / Rated Input Cooling).
3. COP Rated = Coefficient of Performance (Rated Capacity Heating / Rated Input Heating).
4. Refer to AS/NZS 3000 “Australian/New Zealand Wiring Rules” for more details.
5. Refer to the Catalogue Unit Weight Distribution Guide section for details of weight points.
6. Sound Pressure Level at 3m distance is determined as the measured sound pressure at 3m perpendicular to the coil side of the condenser. Sound levels are determined in an anechoic chamber and may differ once the unit is installed due to ambient conditions.
7. Measured based on ISO 3743-1, Determination of Sound Power Levels and Sound Energy Levels of Noise Sources Using Sound Pressure.
8. When the Demand Response capability option is chosen, the air conditioner will be fully compliant with AS4755.3 in the following modes: DRM 1, 2, 3.
9. Achieved when operating on Variable Fan Mode.
Important Notes:
• The Local Electricity Supply Authority may require limits on – starting current, running current, and voltage drop, please check before purchase.
• When the outdoor temperature exceeds the rated conditions, the cooling/heating capacities may decrease the rated net values.
• Specifications are subject to change without notice.
• All pictures shown are for illustration purposes only.
Rated Conditions:
Cooling: 35°C DB Outdoor / Air Entering Indoor 27°C DB, 19°C WB Heating: 7°C DB, 6°C WB Outdoor / Air Entering Indoor 20°C DB
Warranty:
For full terms and conditions of the ActronAir warranty, please refer to the warranty terms document
– www.actronair.com.au
Review ActronAir Advance CRV17AT|EVV17AS 17kW Split Ducted System 3 Phase