SAMSUNG AC160TNHPKG/SA 16.0kW Ducted S2+ Inverter Air Conditioner System 1 Phase
AC160TNHPKG/SA/AC160TXAPKG/SA
Price: (Inc GST)
PRODUCT INFORMATION
- SKU: AC160TNHPKG/SA/ AC160TXAPKG/SA
- 16.0 kW Cooling
- 18.0 kW Heating
- Indoor – AC160TNHPKG/SA 16.0kW Duct S2+, Split table indoor, R32
- Outdoor – AC160TXAPKG/SA 18.0kW Universal outdoor 1 Phase (Duct S2/S2+, Cassettes) R32
- Controller: MWR-WE13N Local Controller, wired, NASA
KEY FEATURES
- Powerful Airflow with more fans than ever: The strong and robust construction of our Duct S2+ Indoor Unit brings a maximum of 25% more air volume than our standard model* meaning you stay comfortable in all parts of your home.
- Energy Superstar – Low Running Cost: The Duct S2+ is a highly energy-efficient system. For an equivalent airflow, it uses less energy*. This leads to a low running cost – meaning you can use your Ducted system all day long without a hefty bill!
- Easy to Install – Lightweight and Compact: Our Duct S2+ Indoor Units are designed to meet the needs of Australian homes. A lightweight and compact design with a quality finish makes the Duct S2+ easy to maneuver into any space.
- Innovative Design – Splittable and Tapered: The Duct S2+ splittable type indoor unit can separate the fan and heat exchanger section, making it easier to position into tight roof space – perfect for renovations. The Duct S2+ indoor unit has a tapered fan motor section that fits in between roof trusses. Combined with hanging brackets positioned to minimize obstruction, the installation has never been this easy.
- Quiet, High Performance – Twin BLDC Compressor and Auto ESP: With a rotary compressor and auto ESP the Duct S2+ heats and cools your spaces in a matter of minutes and maintains optimal air-volume automatically. Able to function in areas with outside air temperatures between −15°C to 50°C for cooling and −20°C to 24°C for heating, enjoy maximum comfort in any Australian environment.
- Hello R32 Refrigerant! – Low GWP (Global Warming Potential) refrigerant: Low GWP (Global Warming Potential) refrigerant
Specifications
Model Name System | Indoor unit | AC160TNHPKG/SA |
Outdoor unit | AC160TXAPKG/SA | |
Capacity | Cooling (Min/Std/Max) (kW) | 5.8 / 15.5 / 18.0 |
Heating (Min/Std/Max) (kW) | 4.2 / 18.0 / 20.0 | |
Efficiency |
Energy grade (Cooling) (EER) | 3.30 |
Energy grade (Heating) (COP) | 3.73 | |
Energy grade (Cooling) (AEER) | 3.30 | |
Energy grade (Heating) (ACOP) | 3.72 |
Specifications
Model Name System | Indoor unit | AC160TNHPKG/SA |
Outdoor unit | AC160TXAPKG/SA | |
Capacity | Cooling (Min/Std/Max) (kW) | 5.8 / 15.5 / 18.0 |
Heating (Min/Std/Max) (kW) | 4.2 / 18.0 / 20.0 | |
Efficiency |
Energy grade (Cooling) (EER) | 3.30 |
Energy grade (Heating) (COP) | 3.73 | |
Energy grade (Cooling) (AEER) | 3.30 | |
Energy grade (Heating) (ACOP) | 3.72 | |
Electrical | MCA (A) | 36.3 |
MFA (A) | 40.0 | |
Indoor Unit |
Power supply (Ф, #, V, Hz) | 1-phase, 220-240V, 50Hz |
Airflow rate (H, M, L) (l/s) | 1,116 / 966 / 800 | |
ESP (L,M,H) (Pa) | 49 / 60 / 100 | |
Sound pressure @ 1.5m (H/L) (dB(A)) | 49 / 45 / 41 | |
Supply air opening (WxH) (mm) | 1154 x 243 | |
Return air opening (WxH) (mm) | 2 x spigot, each spigot to suit Ø16” (Ø400mm) round flexible duct | |
Net weight (kg) | 66.5 | |
Unit dimensions (WxHxD)(mm) | 1350x360x899 | |
Drain connection size (mm) | OD 32 / ID 25 | |
Drain pump (sold separately) | MDP-G075SP (external type), MDP-G075SQ (internal type) | |
Outdoor unit |
Power supply (Ф, #, V, Hz) | 1-phase, 220-240V, 50Hz |
Type | Rotary | |
Sound pressure @ 1m (Cool/Heat) (dB(A)) | 55 / 57 | |
Sound power (Cooling – High) (dB(A)) | 71 | |
Net weight (kg) | 100.5 | |
Net dimensions (WxHxD) (mm) | 940 x 1420 x 330 | |
Installation | Liquid pipe (mm, inch) | 9.52, 3/8″ |
Gas pipe (mm, inch) | 15.8, 5/8″ | |
Max. allowable piping length (m) | 85 | |
Max. allowable piping height (outdoor above indoor) (m) | 30 | |
Pre-charged length (m) | 30 | |
Operating range |
Cooling (°C) | -15 to 50 |
Heating (°C) | -20 to 24 |
X
Reviews (0)
Specifications
Model Name System | Indoor unit | AC160TNHPKG/SA |
Outdoor unit | AC160TXAPKG/SA | |
Capacity | Cooling (Min/Std/Max) (kW) | 5.8 / 15.5 / 18.0 |
Heating (Min/Std/Max) (kW) | 4.2 / 18.0 / 20.0 | |
Efficiency |
Energy grade (Cooling) (EER) | 3.30 |
Energy grade (Heating) (COP) | 3.73 | |
Energy grade (Cooling) (AEER) | 3.30 | |
Energy grade (Heating) (ACOP) | 3.72 |
Specifications
Model Name System | Indoor unit | AC160TNHPKG/SA |
Outdoor unit | AC160TXAPKG/SA | |
Capacity | Cooling (Min/Std/Max) (kW) | 5.8 / 15.5 / 18.0 |
Heating (Min/Std/Max) (kW) | 4.2 / 18.0 / 20.0 | |
Efficiency |
Energy grade (Cooling) (EER) | 3.30 |
Energy grade (Heating) (COP) | 3.73 | |
Energy grade (Cooling) (AEER) | 3.30 | |
Energy grade (Heating) (ACOP) | 3.72 | |
Electrical | MCA (A) | 36.3 |
MFA (A) | 40.0 | |
Indoor Unit |
Power supply (Ф, #, V, Hz) | 1-phase, 220-240V, 50Hz |
Airflow rate (H, M, L) (l/s) | 1,116 / 966 / 800 | |
ESP (L,M,H) (Pa) | 49 / 60 / 100 | |
Sound pressure @ 1.5m (H/L) (dB(A)) | 49 / 45 / 41 | |
Supply air opening (WxH) (mm) | 1154 x 243 | |
Return air opening (WxH) (mm) | 2 x spigot, each spigot to suit Ø16” (Ø400mm) round flexible duct | |
Net weight (kg) | 66.5 | |
Unit dimensions (WxHxD)(mm) | 1350x360x899 | |
Drain connection size (mm) | OD 32 / ID 25 | |
Drain pump (sold separately) | MDP-G075SP (external type), MDP-G075SQ (internal type) | |
Outdoor unit |
Power supply (Ф, #, V, Hz) | 1-phase, 220-240V, 50Hz |
Type | Rotary | |
Sound pressure @ 1m (Cool/Heat) (dB(A)) | 55 / 57 | |
Sound power (Cooling – High) (dB(A)) | 71 | |
Net weight (kg) | 100.5 | |
Net dimensions (WxHxD) (mm) | 940 x 1420 x 330 | |
Installation | Liquid pipe (mm, inch) | 9.52, 3/8″ |
Gas pipe (mm, inch) | 15.8, 5/8″ | |
Max. allowable piping length (m) | 85 | |
Max. allowable piping height (outdoor above indoor) (m) | 30 | |
Pre-charged length (m) | 30 | |
Operating range |
Cooling (°C) | -15 to 50 |
Heating (°C) | -20 to 24 |
Review SAMSUNG AC160TNHPKG/SA 16.0kW Ducted S2+ Inverter Air Conditioner System 1 Phase