DAIKIN FBA85B-CC2V 8.5kW Inverter Slim-Line Ducted System | 1 Phase
FBA85B-CC2V
Price: (Inc GST)
PRODUCT INFORMATION
- Ducted Premium Inverter Slimline one phase
- SKU: FBA85B-CC2V / BRC1E63
- 8.5 kW Cooling
- 10.0 kW Heating
- DAIKIN FBA85B-CC2V 8.5kW Inverter Slim-Line Ducted System | 1 Phase
- (Old System Number: FBA85B-CCV)
- Indoor Unit: FBA85BVMA
- Outdoor Unit: RZAC85CV1 (Old System Number: RZAC85C2V1)
- Included: BRC1E63 – Standard Controller
KEY FEATURES
Slim-Line Indoor: Industry leading low profile design of 245mm height ensures clearance in most narrow roof spaces.
Design Flexibility: DC fan with an static pressure of 150Pa and up to 85m (100-140 Class) of available pipe run to suit your design layout.
R22 Retrofit Capability: Provides a cost effective and convenient upgrade from an existing R22 ducted system whilst retaining the field piping.
Automatic Airflow Adjustment: Allows the fan speed to adjust automatically to suit your duct design for optimum airflow distribution.
Flexible Return Air: Option of a rear or bottom suction return allows for greater installation flexibility.
Built-in condensate pump: DC condensate pump is equipped as standard with a 850mm lift.
Specifications
Indoor Unit | FBA85BVMA | |
Outdoor Unit | RZAC85CV1 | |
Rated Capacity | Cool (kW) | 8.5 |
Heat (kW) | 10.0 | |
Capacity Range | Cool (kW) | 3.2-10.0 |
Heat (kW) | 3.5-11.2 | |
Power Input (Rated) | Cool (kW) | 2.64 |
Heat (kW) | 2.95 | |
E.E.R/C.O.P | C/H | 3.22/3.39 |
Specifications
Indoor Unit | FBA85BVMA | |
Outdoor Unit | RZAC85CV1 | |
Rated Capacity | Cool (kW) | 8.5 |
Heat (kW) | 10.0 | |
Capacity Range | Cool (kW) | 3.2-10.0 |
Heat (kW) | 3.5-11.2 | |
Power Input (Rated) | Cool (kW) | 2.64 |
Heat (kW) | 2.95 | |
E.E.R/C.O.P | C/H | 3.22/3.39 |
TCSPF (Residential) | Hot/Average/Cold | 4.33/3.88/3.97 |
HSPF (Residential) | Hot/Average/Cold | 4.24/3.83/3.49 |
Airflow Rate (Nominal) | l/s | 533 |
Indoor Sound Level (H) @1.5m | dBA | 38 |
Piping Length | m | 50 |
Indoor Fan Speeds | H/M/L | |
Dimensions (HxWxD) | Indoor (mm) | 245x1400x800 |
Outdoor (mm) | 990x940x320 | |
Weight | Indoor (kg) | 47 |
Outdoor (kg) | 69 | |
Power Supply | V/Hz | 1 Phase, 220-240V, 50Hz |
Compressor Type | Hermetically Sealed Swing Type | |
Refrigerant | R32 | |
Pipe Sizes | Liquid (mm) | 9.5 (Flared) |
Gas (mm) | 15.9 (Flared) | |
Drain (mm) | ID 25 / OD 32 | |
Supply Air Opening | mm (HxW, Flange) | 176×1192 |
Return Air Opening | mm (HxW, Flange) | 208×1352 |
Outdoor Operating Range | Cool (ºCDB) | -5 to 46 |
Heat (ºCWB) | -15 to 16 | |
EPA Sound Power Level | dBA | 70 |
Outdoor Sound Level (H) @1m | Pressure dBA (C/H) | 51/54 |
Reviews (0)
Specifications
Indoor Unit | FBA85BVMA | |
Outdoor Unit | RZAC85CV1 | |
Rated Capacity | Cool (kW) | 8.5 |
Heat (kW) | 10.0 | |
Capacity Range | Cool (kW) | 3.2-10.0 |
Heat (kW) | 3.5-11.2 | |
Power Input (Rated) | Cool (kW) | 2.64 |
Heat (kW) | 2.95 | |
E.E.R/C.O.P | C/H | 3.22/3.39 |
Specifications
Indoor Unit | FBA85BVMA | |
Outdoor Unit | RZAC85CV1 | |
Rated Capacity | Cool (kW) | 8.5 |
Heat (kW) | 10.0 | |
Capacity Range | Cool (kW) | 3.2-10.0 |
Heat (kW) | 3.5-11.2 | |
Power Input (Rated) | Cool (kW) | 2.64 |
Heat (kW) | 2.95 | |
E.E.R/C.O.P | C/H | 3.22/3.39 |
TCSPF (Residential) | Hot/Average/Cold | 4.33/3.88/3.97 |
HSPF (Residential) | Hot/Average/Cold | 4.24/3.83/3.49 |
Airflow Rate (Nominal) | l/s | 533 |
Indoor Sound Level (H) @1.5m | dBA | 38 |
Piping Length | m | 50 |
Indoor Fan Speeds | H/M/L | |
Dimensions (HxWxD) | Indoor (mm) | 245x1400x800 |
Outdoor (mm) | 990x940x320 | |
Weight | Indoor (kg) | 47 |
Outdoor (kg) | 69 | |
Power Supply | V/Hz | 1 Phase, 220-240V, 50Hz |
Compressor Type | Hermetically Sealed Swing Type | |
Refrigerant | R32 | |
Pipe Sizes | Liquid (mm) | 9.5 (Flared) |
Gas (mm) | 15.9 (Flared) | |
Drain (mm) | ID 25 / OD 32 | |
Supply Air Opening | mm (HxW, Flange) | 176×1192 |
Return Air Opening | mm (HxW, Flange) | 208×1352 |
Outdoor Operating Range | Cool (ºCDB) | -5 to 46 |
Heat (ºCWB) | -15 to 16 | |
EPA Sound Power Level | dBA | 70 |
Outdoor Sound Level (H) @1m | Pressure dBA (C/H) | 51/54 |
Review DAIKIN FBA85B-CC2V 8.5kW Inverter Slim-Line Ducted System | 1 Phase